Size: 2 (ø15), Valve Type: 1 [NC (Operating Pressure 1MPa)], Sealant: A (NBR), Thread: Rc, Port Size: 15A (1/2), Voltage: 5 (24VDC), Lead Wire: DZ (DIN Terminal w/Light & Surge Voltage Suppressor), Manual Override: B (Locking Style Slotted)
Size: 2 (ø15), Valve Type: 1 [NC (Operating Pressure 1MPa)], Sealant: A (NBR), Thread: Rc, Port Size: 15A (1/2), Voltage: 5 (24VDC), Lead Wire: G (Grommet)
Size: 2 (ø15), Valve Type: 1 [NC (Operating Pressure 1MPa)], Sealant: A (NBR), Thread: Rc, Port Size: 15A (1/2), Voltage: 1 (100VAC 50/60HZ), Lead Wire: DZ (DIN Terminal w/Light & Surge Voltage Suppressor)
Size: 2 (ø15), Valve Type: 1 [NC (Operating Pressure 1MPa)], Sealant: A (NBR), Thread: Rc, Port Size: 15A (1/2), Voltage: 1 (100VAC 50/60HZ), Lead Wire: G (Grommet)
Size: 2 (ø15), Valve Type: 1 [NC (Operating Pressure 1MPa)], Sealant: A (NBR), Thread: Rc, Port Size: 15A (1/2), Voltage: 3 (110VAC 50/60HZ), Lead Wire: G (Grommet)
Size: ø15, Valve Type: 1 [NC (Operating Pressure 1MPa)], Sealant: NBR, Thread: Rc, Port Size: 1/2, Voltage: 220VAC 50/60HZ, Lead Wire: DIN Terminal, Manual Override: -, Bracket: -, X200: -, CE Compliant: -
Size: ø15, Valve Type: 1 [NC (Operating Pressure 1MPa)], Sealant: NBR, Thread: Rc, Port Size: 1/2, Voltage: 24VDC, Lead Wire: Grommet Terminal, Manual Override: -, Bracket: -, X200: -, CE Compliant: -
Size: ø15, Valve Type: 1 [NC (Operating Pressure 1MPa)], Sealant: NBR, Thread: Rc, Port Size: 1/2, Voltage: 24VDC, Lead Wire: Grommet, Manual Override: Locking Style Slotted, Bracket: -, X200: -, CE Compliant: -
Size: ø15, Valve Type: 1 [NC (Operating Pressure 1MPa)], Sealant: NBR, Thread: Rc, Port Size: 1/2, Voltage: 220VAC 50/60HZ, Lead Wire: DIN Terminal w/Light & Surge Voltage Suppressor, Manual Override: -, Bracket: -, X200: -, CE Compliant: -
Size: ø15, Valve Type: 1 [NC (Operating Pressure 1MPa)], Sealant: NBR, Thread: Rc, Port Size: 1/2, Voltage: 100VAC 50/60HZ, Lead Wire: Conduit Terminal w/Light & Surge Voltage Suppressor, Manual Override: -, Bracket: -, X200: -, CE Compliant: -
Size: ø15, Valve Type: 1 [NC (Operating Pressure 1MPa)], Sealant: NBR, Thread: Rc, Port Size: 1/2, Voltage: 110VAC 50/60HZ, Lead Wire: Conduit Terminal w/Light & Surge Voltage Suppressor, Manual Override: -, Bracket: -, X200: -, CE Compliant: -
Size: ø15, Valve Type: 1 [NC (Operating Pressure 1MPa)], Sealant: NBR, Thread: Rc, Port Size: 1/2, Voltage: 24VDC, Lead Wire: Conduit Terminal, Manual Override: -, Bracket: -, X200: -, CE Compliant: -
Size: ø15, Valve Type: 1 [NC (Operating Pressure 1MPa)], Sealant: NBR, Thread: Rc, Port Size: 1/2, Voltage: 24VDC, Lead Wire: Conduit Terminal w/Light & Surge Voltage Suppressor, Manual Override: -, Bracket: -, X200: -, CE Compliant: -
Size: 2 (ø15), Valve Type: 1 [NC (Operating Pressure 1MPa)], Sealant: A (NBR), Thread: Rc, Port Size: 15A (1/2), Voltage: 3 (110VAC 50/60HZ), Lead Wire: DZ (DIN Terminal w/Light & Surge Voltage Suppressor)
Fit the grooved part of gasket w into the flange part of case q. b. Place element e in case q. Element e must be positioned at the center of case q. c. Set clamp ring t to case q. The tapered part of clamp ring t must be facing downward. d. Set seal part of the element e to the cover r while the flange part of case q is being placed on clamp ring t. e.
r e w q r e w q VG VP S070 VQ VKF N.C.
1, Metal joint q, w End plate (D) !2, Connection bracket q, w, Gasket e, r, O-ring y, u End plate (D) !2, Connection bracket q, w, Gasket e, t, O-ring y, u Non plug-in type Plug-in type VVF4000-3A-2 !
0, Terminal i, Metal joint q, w, Gasket r, Receptacle assembly Manifold block !0, Metal joint q, w, Gasket r End plate (U) !1, Metal joint q, w End plate (U) !1, Metal joint q, w End plate (D) !2, Metal joint q, w, Gasket e, t, O-ring y, u End plate (D) !2, Metal joint q, w, Gasket e, t, O-ring t, y 03 04 VVF4000-1A-1Plug-in type Manifold block assembly !
In the case of liquids: DP Q = 1.9 x 106Av (9) G Q : Flow rate [L/min] Av : Flow coefficient [m2] DP : Pressure difference [MPa] G : Relative density [water = 1] In the case of saturated aqueous vapor: Q = 8.3 x 106Av DP(P2 + 0.1) (10) Q : Flow rate [kg/h] Av : Flow coefficient [m2] DP : Pressure difference [MPa] P1 : Upstream pressure [MPa]: DP = P1 P2 P2 : Downstream pressure [MPa] 11
A l a r m S e q u e n c e M O D E < O f f sequence(Ex. : Off) Function : Determines whether or not temp. upper/lower limit alarm is output when power is turned on.