Size: 1 [ø7], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: NBR seal, Thread: Rc(PT), Port Size: 1/4, Voltage: 100VAC 50/60HZ, Lead Wire: DIN Terminal, Manual Override: -, Bracket: -, CE Compliant: -
Size: 1 [ø7], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: NBR seal, Thread: Rc(PT), Port Size: 1/4, Voltage: 24VDC, Lead Wire: DIN Terminal w/Light & Surge Voltage Suppressor, Manual Override: -, Bracket: -, CE Compliant: -
Size: 1 [ø7], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: NBR seal, Thread: NPT, Port Size: 1/4, Voltage: 110VAC 50/60HZ, Lead Wire: Grommet w/Surge Suppressor, Manual Override: Locking Style Slotted, Bracket: -, CE Compliant: -
Size: 1 [ø7], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: NBR seal, Thread: NPTF, Port Size: 3/8, Voltage: 200VAC 50/60HZ, Lead Wire: Grommet w/Surge Suppressor, Manual Override: Locking Style Slotted, Bracket: -, CE Compliant: -
Size: 1 [ø7], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: NBR seal, Thread: NPTF, Port Size: 1/4, Voltage: 100VAC 50/60HZ, Lead Wire: Grommet, Manual Override: -, Bracket: -, CE Compliant: -
Size: 1 [ø7], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: NBR seal, Thread: NPT, Port Size: 1/8, Voltage: 100VAC 50/60HZ, Lead Wire: Grommet Terminal, Manual Override: Locking Style Slotted, Bracket: -, CE Compliant: -
Size: 1 [ø7], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: NBR seal, Thread: F [G(PF)], Port Size: 3/8, Voltage: 200VAC 50/60HZ, Lead Wire: Grommet, Manual Override: Locking Style Slotted, Bracket: -, CE Compliant: -
Size: 1 [ø7], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: NBR seal, Thread: NPTF, Port Size: 1/4, Voltage: 100VAC 50/60HZ, Lead Wire: Conduit Terminal, Manual Override: -, Bracket: -, X200: -, CE Compliant: -
Size: 1 [ø7], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: NBR seal, Thread: Rc(PT), Port Size: 3/8, Voltage: 100VAC 50/60HZ, Lead Wire: Conduit Terminal w/Light & Surge Voltage Suppressor, Manual Override: -, Bracket: -, X200: -, CE Compliant: -
Size: 1 [ø7], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: NBR seal, Thread: Rc(PT), Port Size: 3/8, Voltage: 110VAC 50/60HZ, Lead Wire: Conduit Terminal, Manual Override: -, Bracket: -, X200: -, CE Compliant: -
Size: 1 [ø7], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: NBR seal, Thread: Rc(PT), Port Size: 1/4, Voltage: 100VAC 50/60HZ, Lead Wire: Conduit Terminal, Manual Override: -, Bracket: -, X200: -, CE Compliant: -
Size: 1 [ø7], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: NBR seal, Thread: Rc(PT), Port Size: 1/4, Voltage: 24VDC, Lead Wire: Conduit Terminal w/Light & Surge Voltage Suppressor, Manual Override: -, Bracket: -, X200: -, CE Compliant: -
Size: 1 [ø7], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: A (NBR seal), Thread: F [G(PF)], Port Size: 10A (3/8), Voltage: 2 (200VAC 50/60HZ), Lead Wire: GS (Grommet w/Surge Suppressor)
Size: 1 [ø7], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: A (NBR seal), Thread: Rc(PT), Port Size: 8A (1/4), Voltage: 1 (100VAC 50/60HZ), Lead Wire: D (DIN Terminal), Manual Override: B (Locking Style Slotted)
Size: 1 [ø7], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: A (NBR seal), Thread: Rc(PT), Port Size: 10A (3/8), Voltage: 5 (24VDC), Lead Wire: DZ (DIN Terminal w/Light & Surge Voltage Suppressor)
Weight Table/Aluminum Tube (1 00) I Bore size (mm) 32 40 50 6a .80 100 Bask: 1.23 1.85 3.06 4.20 7.08 9.33 Fool 1.58 2.29 3.89 5.21 9.04 11.73 Theoretical Output Table Basic weight Flange 1.67 2.35 4.09 5.46 9.94 13.31 OUT side IS identical 1 0 double acUng single rod. Single clevis 1.58 2.35 3.87 5.52 9.44 13. 13 Refer to table below lor IN side.
(Tightening torque: 0.25 to 0.35 Nm) Station 5 (+) () SOL.B 5B The quantity of terminal blocks used depends on the number of manifold stations: SOL.A (+) () 6A Station 6 SOL.B (+) () 6B Manifold Terminal block SOL.A (+) () 7A 2 to 8 stations 2 rows Station 7 SOL.B (+) () 7B 9 to 12 stations 3 rows SOL.A (+) () 8A Station 8 SOL.B (+) () 8B As the standard electrical wiring specifications,
Dd9 Knuckle 40, 50, 63 80 100 3 x 18l 3 x 18l 4 x 25l 4 x 25l 4 x 30l 4 x 36l CDP-2A CDP-3A CDP-4A CDP-5A CDP-6A CDP-7A 10 0.046 0.076 12 0.050 0.093 16 0.050 0.093 18 0.050 0.093 20 0.065 0.117 25 0.065 0.117 46 55.5 71 76.5 83 88 4 4 5 5 5 6 3 3 4 4 4 4 38 47.5 61 66.5 73 78 Material: Rolled steel Applicable bore size (mm) 40 50, 63 80 100 d D H B C Part no.
Station 4 SOL.B 4B SZ Cover SOL.A 5A Station 5 SOL.B 5B SOL.A VF 6A Station 6 SOL.B 6B SOL.A 7A VP4 Station 7 SOL.B 7B SOL.A As the standard electrical wiring specifications, double wiring (connected to SOL. A and SOL. B) is adopted for the internal wiring of each station for 10 stations or less, regardless of valve and option types.
Dd9 Knuckle 40, 50, 63 80 100 3 x 18l 3 x 18l 4 x 25l 4 x 25l 4 x 30l 4 x 36l CDP-2A CDP-3A CDP-4A CDP-5A CDP-6A CDP-7A 10 0.046 0.076 12 0.050 0.093 16 0.050 0.093 18 0.050 0.093 20 0.065 0.117 25 0.065 0.117 46 55.5 71 76.5 83 88 4 4 5 5 5 6 3 3 4 4 4 4 38 47.5 61 66.5 73 78 Material: Rolled steel Applicable bore size (mm) 40 50, 63 80 100 d D H B C Part no.