P1, L1 C2 S/S. P1, L1 C3 S/S. P1, L1 C4 S/S. P1, L1 C6 S/S. P1, L1 RC3-1 S/S . P1, L2 T1 S/S . P1, L4 T2 S/S . P1, L4 T3 S/S . P1, L4 T4 S/S . P1, L4 T6 S/S . P1, L4 RT3-1-1 S/S . P2, L5 RT3-3-1 S/S . P2, L5 RT3-1-3 S/S . P2, L5 RT1-3-1 S/S . P2, L5 X1 S/S . P3, L10 1 2 1 2 1/2 B Thd D A Thd C Hole Dia. Stainless Steel Threaded Parts Page & Part No. Line No. Page & Part No. Line No.
Note 2) Replacement part numbers correspond to the item numbers in the figures. 14-5-18 18 Precision Regulator Series IR1000/2000/3000 Dimensions IRV1000-01 IRV2000-02 53 55 16.5 2.3 30 22 2.3 41 (R) F.R.L.
Clamp arm 0.05 MPa or less Lock at extended direction (unclamp direction) 1.0 MPa Round, Diamond Guide pin shape Locking direction Refer to Selection in page 22 regarding detailed specifications of the clamping force, etc.
3.2 D-M9B (2-wire) OUT Black Most sensitive position 6 DC(-) Blue 22 D-M9B OUT(+) Brown OUT(-) Blue 18
32 16 30 25 2 x 1/4 2 x 5.5 mounting hole 40 * 0.5 MPa supply F .O.F .* 52 N T.T. 5.8 mm 22 Series VM100/200 Specific Product Precautions 1 Be sure to read before handling.
ISE When the values of P1 and P2 are the same or when P1>P2 within three digits, the hysteresis will be automatically three digits for the set value of P1. Window comparator mode: ZSE The hysteresis is two digits, so separate P1 from P2 by five digits or more and set them.
32 22 32 28 40 28 40 33 50 33 50 45 65 56 80 3 8 0.7 0.5 1 2 3 4 0.8 1.0 1.2 1.4 1 1 4 1 2.2 2.4 5.0 5.2 32 1 2 1 3.6 3.8 Symbol 6.8 7.0 40 Valve type Operation N.C.
How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 + 0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q: Air flow rate [l/min (ANR)] S: Effective area [mm] P: Pressure drop rate (P1P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Correction for different air temperatures
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 60
Note 3) Hysteresis mode: When the values of P1 and P2 are the same or when |P1| > |P2| within 3 digits, the hysteresis will be automatically 3 digits for the set value of P1. Window comparator mode: The hysteresis is 3 digits, so separate P1 from P2 by 7 digits or more and set them. 1 digit is the minimum pressure display unit. (See the table above.)
How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 +0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q: Air flow rate [l/min(ANR)] S: Effective sectional area (mm) P: Differential pressure (P1-P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Correction for different air temperatures
(Copper-free) VH VHS IN P1 Flow Rate and Effective Area OUT IN P2 VR1211F Model Metric size 6 3.2 4 Applicable tubing O.D. If air is only supplied only to either P1 or P2 it, does not flow to the OUT side.
L1 L2 L2 Main circuit power supply L3 L3 Regenerative converter N P1 P2 N DC reactor Connect between P1 and P2. (Connected at time of shipping.) P1 Control Circuit Power Supply Connector: CNP2 Accessory P2 Terminal name Function Function details P P C D L11 L21 Connect between P and D. (Connected at time of shipping.)
If a moment or torque directly acts on the cylinder, it will lead to reduced service life or damage to machinery. 7 3 Position Cylinder Series RZQ Construction 13 24 21 3 2 1 6 4 8 7 10 19 22 20 12 23 11 9 5 23 18 14 16 17 15 22 Parts list No. 1 2 3 4 5 6 7 8 9 10 11 12 No. 13 14 15 16 17 18 19 20 21 22 23 24 Note Note Description Material Description Material Hard anodized Aluminum alloy
(Option) 30 2 ARJ 2.3 48 Pressure gauge (Option) AR425 to 935 Pressure gauge (Option) ARX 5.5 9.5 M5 depth 7 AMR 9 M5 depth 7 2 x Rc 1/8 15.5 IN 119 Pressure gauge port 83 75 Bleed Bleed IN ARM Exhaust IN OUT(2) Bleed Bleed SUP(1) IN G 2 OUT 144 43 G ARP 76 22 2 x Rc 1/8 Pressure gauge port 50 50 (17.7) 2 x Rc 1/4 Port size IR-A EXH(3) OUT 2 OUT(2) SUP(1) 60 Rc 1/2 Exhaust port 66 2 x Rc
Recommended proper torque Nm (kgfcm) 1/8 1/4 3/8 1/2 Connection thread 7 to 9 (70 to 90) 12 to 14 (120 to 140) 22 to 24 (220 to 240) 28 to 30 (280 to 300) Winding direction Torque Expose approx. 2 threads Pipe tape Operating Environment Warning 1.
or less 0.2 600 0.27 0.17 1.1 0.21 0.23 0.90 1 8 VP4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Exhaust center 3 position VZS2450 22 or less 600 0.2 0.31 0.13 1.3 0.25 0.12 1.1 1 8 VZS Pressure center VZS2550 600 22 or less 0.2 0.33 0.19 1.4 0.26 0.12 1.2 1
8.5 8.5 11 8.4 10 19 19 27.5 27 36.5 43.5 43.5 49.5 40 53 70 70 90 75.4 90.9 119.4 123.4 152.3 31.3 40 53 55 71 25.3 33 44 46 60 53.3 30 41 50 50 70 2.3 2.3 2.8 2.8 3.2 3 3 3 4 4 12 14 19 22 22 67 79 79 108 6 Series VHS20/30/40/50 Series VHS2510/3510/4510/5510 Specific Product Precautions 1 Be sure to read before handling.
VQZ SOL.A 8 8 () (+) Purple White SOL.A SOL.B 21 21 () (+) Brown White 8 stations SOL.B SOL.A 9 9 () (+) Gray Black SOL.A VQD SOL.B 22 22 () (+) Pink Red 9 stations Connector terminal no. SOL.B SOL.A 10 10 () (+) White Black SOL.A Double wiring (connected to SOL. A and SOL. B) is adopted for the internal wiring of each station, regardless of valve and option types.
L-bracket 2.3 30 36 52 40 22 Straight type 3 m Cable connector TM-4DSX3HG4 50 Right angle type 3 m 4 x 5.5 8 x 4.5 4 x 7 22 TM-4DLX3HG4 50 36 40 84 40 36 22 40 5 36 7 4 x 5.5 8 x 4.5 22 14 20 60 70 12 1.6 14-8-15 16 Series ITV1000/2000/3000 Working Principle When the input signal rises, the air supply solenoid valve q turns ON, and the exhaust solenoid valve w turns OFF.