Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: Supply: NC, Release: None, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S., Air Pressure Supply, P Port
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: Supply: NC, Release: None, Pilot Valve: DC Low Wattage Type (0.5W, Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S., Air Pressure Supply
When the inlet pressure (P1) is shut off and released, the check valve w, opens and the pressure in the diaphragm chamber q is released into the inlet side (Figure 2). This lowers the pressure in the diaphragm chamber q, and the force generated by pressure regulator spring e lifts the diaphragm.
VQ1100-52 sets-Valve No. (Stations 1 to 2) VQ1200-54 sets-Valve No. (Stations 3 to 6) VQ1300-52 sets-Valve No. (Stations 7 to 8) VVQ1000-10A-11 set-Blank plate No.
SUP. 3 1 2 3 1 2 3 1 2 E Padlock mounting position D C SUP J 2 2 x K A T IN OUT AA 3 L 2 x P1 (Port size) B V BB U Built-in silencer (Option) M (Width across flats) 3 N P2 (Port size) Q EXH Y Bracket (Option) R S X W Dimensions (mm) Standard specifications Model P1 P2 A B C D E F G H I J K L M 1/8, 1/4 1/4, 3/8 1/8 1/4 3/8 1/2 1/2 66.4 80.3 104.9 110.4 134.3 22.3 29.4 38.5 42 53 40 53 70
Q=14.2Cv 10.2 P l/min G Formula based on effective area (Smm) Q=0.8S 10.2P l/min G Other : Flow rate (l/min) : Pressure differential (P1 P2) : Upstream pressure (MPa) : Downstream pressure (MPa) : Effective area (mm) : Cv factor : Fluid specific gravity (water = 1) Q P P1 P2 S Cv G 1. Materials FKM: Fluoro rubber Trade names: Viton, Dai-el, etc. 2.
Q=14.2Cv 10.2 P l/min G Formula based on effective area (Smm) Q=0.8S 10.2P l/min G Other : Flow rate (l/min) : Pressure differential (P1 P2) : Upstream pressure (MPa) : Downstream pressure (MPa) : Effective area (mm) : Cv factor : Fluid specific gravity (water = 1) Q P P1 P2 S Cv G 1. Materials FKM: Fluoro rubber Trade names: Viton, Dai-el, etc. 2.
The small pressure difference (P2 P1) that is created when a part is picked by the (S4) picking nozzle and is detected by the pressure sensor. AMJ Pressure sensor Vacuum source Misc. Adsorption nozzle (0.3 to 1.2) Wiring is the same as ZSE2. Filter case How to Order Caution S 0X 15 ZSP1 1. The case is made of polycarbonate.
MHT MHY MHW Weight Auto Switch Internal Circuit D-F8N MRHQ (g) D-F8N D-F8P D-F8B Auto switch model DC (+) Brown Misc. 0.5 7 7 7 Lead wire length (m) 3 32 Main circuit of switch Main circuit of switch Main circuit of switch 32 32 DOUT Black 5 52 52 52 20DC () Blue Dimensions D-F8N, D-F8P, D-F8B D-F8P Mounting screw M2.5 x 4l Slotted set screw DC (+) Brown 4.3 Indicator light 2 2.7 OUT Black
Common External Pilot Piping VVEX2-2 VVEX4-2 PE: Pilot exhaust PE: Pilot exhaust R P P1 P P1 R P1: Common external pilot port P1: Common external pilot port How to Order Manifold Base Note) Air operated The VEX3220 and VEX3420 (air operated) are used. Distinction between the pilots (internal or common external pilot) of the manifold base does not matter.
(Blanking plate assembly) DXT192-52-1-4A 3 pcs. (Connector assembly) DXT192-52-2-4A 3 pcs. (Connector assembly) The asterisk denotes the symbol for assembly.
AL30 Rc 3/8 AL60 Rc 1 0.1 0.1 P1 = 0.7 MPa Pressure drop (MPa) Pressure drop (MPa) 0.08 0.08 P1 = 0.5 MPa Selection P1 = 0.3 MPa P1 = 0.3 MPa P1 = 0.5 MPa P1 = 0.7 MPa P1 = 0.1 MPa Warning 1. Do not introduce air from the outlet side as this can damage the damper. 0.06 0.06 P1 = 0.1 MPa 0.04 0.04 Caution 1.
P1 = 0.5MPa 0.08 0.08 Pressure drop MPa Pressure drop MPa P1 = 0.3MPa P1 = 0.1MPa P1 = 0.1MPa 0.06 0.06 0.04 0.04 0.02 0.02 0 0 15000 10 5000 1000 2000 3000 4000 0 0 Flow rate L/min (ANR) Flow rate L/min (ANR) AL60 Rc 1 AL30 Rc 3/8 0.1 0.1 Specific Product Precautions P1 = 0.7MPa 0.08 0.08 P1 = 0.5MPa Pressure drop MPa Pressure drop MPa P1 = 0.3MPa P1 = 0.3MPa P1 = 0.5MPa P1 = 0.7MPa P1 =
External Pilot Adiabatic Space Caution Caution Pilot port 12(P1) and 10(P2) piping P1 and P2 piping should be as follows according to the model. There is a space between body and cover (: approximate 1 mm) for adiabatic effect.
) 10 (P2) 12 (P1) Allowable voltage fluctuation SGC 50C or less (When rated voltage is applied.)
Example: The figure below is based on the condition of set values as P1 = 40 [kPa] and P2 = 20 [kPa].
Check that if it does not exceed the upper limit, by referring to the specications (Page 52).
Perl t Nns 4024 ilVS /1034 l'll/S 4044 2 PGition 3 Podtoo 2 Posilion 3 Poition 2 Poition 1121.42244324,4424 r13,,42344334, 4/|i|{ 4144,4244 12 VDC A06-51 AO9-51 A07-51 A10-51 A08-51 24 VDC A06-52 409-52 A07-52 A10-52 A08-52 48 VDC A06-53 A09-53 A07-53 A10-53 A08-53 Powar Conaumptlon: (13.2 WEtts) D.C. solenoidE alwaF draw the same amount of powsr, regardless of th6 posltlon of the plunger
) 12 (P1) 10 (P2) PB Power consumption DC Holding Inrush Apparent power AC Air operated 2 (B) 1 (A) 2 (B) 1 (A) 2 (B) 1 (A) 10 (P2) Manual override VNA11 VNA12 12 (P1) 12 (P1) External pilot solenoid 1 (A) 2 (B) 2 (B) 1 (A) 17-4-7 4 Series VNA Port size 6A, 8A, 10A Applicable cable O.D. 6 to 8 (D.T) 125 (Conduit terminal: T DIN terminal: D) 108.2 (Grommet terminal: E) 106.7 (Grommet: G) 63
S kit (Serial transmission kit: EX250) M12 female input connector M4 x 7 earth thread 2 x Rc, G (According to ISO1179-1), NPTF 3/8" 3(R) port Rc, G (According to ISO1179-1), NPTF 1/8" Pilot port Rc, G (According to ISO1179-1), NPTF 1/8" Pilot exhaust port M8 female input connector 0 57.5 82 0 BUS 60 30 1 35.5 1 31.3 2 PWR 3 22 28.5 129.5 M12 male power connector 11.3 13.5 19 (n-1) x 19 52