SMC Corporation of America
Elite Part Number Search
Search Results "ZSE10-M5-C-MGR"

, PRESSURE SWITCH, INSTRUMENTATION, ISE30/ISE30A PRESSURE SWITCH, AA, ISE30 M5 PT VERSION, 0.3446 lb

, PRESSURE SWITCH, INSTRUMENTATION, ISE30/ISE30A PRESSURE SWITCH, AA, ISE30 M5 PT VERSION, 0.22046 lb

ZSE10/ISE10 compact, digital pressure switch has been reduced in height by approximately 50% when compared to the I/ZSE30A.? Up to 10 slave sensors can be set at once using the copy settings function.? Options include?direct mount, panel mount?or DIN rail mount, and a choice of 2 piping directions.?

ZSE10/ISE10 compact, digital pressure switch has been reduced in height by approximately 50% when compared to the I/ZSE30A.? Up to 10 slave sensors can be set at once using the copy settings function.? Options include?direct mount, panel mount?or DIN rail mount, and a choice of 2 piping directions.?

ZSE10/ISE10 compact, digital pressure switch has been reduced in height by approximately 50% when compared to the I/ZSE30A.? Up to 10 slave sensors can be set at once using the copy settings function.? Options include?direct mount, panel mount?or DIN rail mount, and a choice of 2 piping directions.?

ZSE10/ISE10 compact, digital pressure switch has been reduced in height by approximately 50% when compared to the I/ZSE30A.? Up to 10 slave sensors can be set at once using the copy settings function.? Options include?direct mount, panel mount?or DIN rail mount, and a choice of 2 piping directions.?

ZSE10/ISE10 compact, digital pressure switch has been reduced in height by approximately 50% when compared to the I/ZSE30A.  Up to 10 slave sensors can be set at once using the copy settings function. 

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A. Up to 10 slave sensors can be set at once using the copy settings function.

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.? Up to 10 slave sensors can be set at once using the copy settings function.? Options include?direct mount, panel mount?or DIN rail mount, and a choice of 2 piping directions.?

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A. Up to 10 slave sensors can be set at once using the copy settings function.

Make sure that the clip (C) is locked and there is no gap in part (D). Notch Hook A C Hook B w q D Note) If excess force is applied to the filter case, hook A and B may break. Handle with care. 29 Series ZK2 Specific Product Precautions 4 Be sure to read the below before handling. Refer to back cover for Safety Instructions.

Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: M (Fixed SI Unit, kPa), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)]

Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: M (Fixed SI Unit, kPa), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)]

Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: M (Fixed SI Unit, kPa), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)]

Pressure Range: F (-100.0 to 100kPa), Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: M (Fixed SI Unit, kPa), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)]

Pressure Range: F (-100.0 to 100kPa), Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: M (Fixed SI Unit, kPa), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)]

Pressure Range: F (-100.0 to 100kPa), Piping Specifications: M5 (M5 Female Thread/Side Piping Port), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: M (Fixed SI Unit, kPa), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)]

Type: Pressure Switch, Fluid Type: Air, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Analog Output Specification: -, Pipe Port Type: Female Thread, Plumbing Thread Type: M, Plumbing Thread Nominal: M5x0.8, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating Temperature Range(°C): -5~50, Operating Humidity Range(%): 35~85, Number

Type: Pressure Switch, Fluid Type: Air, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Analog Output Specification: -, Pipe Port Type: Female Thread, Plumbing Thread Type: M, Plumbing Thread Nominal: M5x0.8, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating Temperature Range(°C): -5~50, Operating Humidity Range(%): 35~85, Number

Type: Pressure Switch, Fluid Type: Air, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Analog Output Specification: -, Pipe Port Type: Female Thread, Plumbing Thread Type: M, Plumbing Thread Nominal: M5x0.8, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 0.5, Operating Temperature Range(°C): -5~50, Operating Humidity Range(%): 35~85, Number