63 32 40 50 63 12 8 30 9 5 27.5 16 12 32 11.5 7.5 30 14 10 37.5 14.5 10.5 35 16.5 12.5 42.5 17.5 13.5 40.5 Note) The actual mounting position should be adjusted after confirming the auto switch performance.
temperature [C] 0 0 10 20 30 40 50 60 70 Circulating fluid temperature [C] For the high-pressure pump (Option), the heating capacity increases by approx. 10 W.
9 10 10 10 ZP20U ZPT3-7A-X2 ZP 25 U ZPG25U-7A-X2 10 10 10 11 ZP25U ZP 32 U ZPG32U-7A-X2 10 11 11 12 ZP32U ZP 10 C ZPG10C-7A-X2 7 7 7 7 ZP10C ZPT2-7A-X2 ZP 13 C ZPG13C-7A-X2 7 7 7 7 ZP13C ZP 16 C ZPG16C-7A-X2 7 7 7 8 ZP16C ZP 20 C ZPG20C-7A-X2 9 10 10 11 ZP20C ZPT3-7A-X2 ZP 25 C ZPG25C-7A-X2 10 10 10 11 ZP25C ZP 32 C ZPG32C-7A-X2 10 11 11 12 ZP32C ZP 10 B ZPG10B-7A-X2 7 7 7 8 ZP10B
Size 1 2 1 2 3 1 2 1 2 A B C A B A B A B 2 2 3 3 3 4 4 5 5 2 2 2 3 3 4 4 5 5 1/4" x 5/32" 3/16" x 1/8" 1/8" x 0.086" 3/8" x 1/4" 1/4" x 5/32" 1/2" x 3/8" 3/8" x 1/4" 3/4" x 5/8" 1/2" x 3/8" 6 x 4 4 x 3 10 x 8 8 x 6 6 x 4 12 x 10 10 x 8 19 x 16 12 x 10 SMC SMC P U Panel mount union Union SMC SMC With reducer Basic size Note) Select the fittings of the same size as the one at the valve side
x 8 8 x 6 6 x 4 10 x 8 8 x 6 6 x 4 12 x 10 10 x 8 12 x 10 10 x 8 19 x 16 12 x 10 19 x 16 12 x 10 25 x 22 19 x 16 25 x 22 19 x 16 Tubing O.D.
thread depth J 2-Port size D I NB NB T N K W N S + Stroke F F NA R ZZ + Stroke 43 35 29 22 20.5 27.8 D Model Port size K NN B L MM x J N NA H 16 15 10 I 46 36 30 NB 19 17 17 T S 11 9 8 G ZZ 10 8 8 R 60 50 50 W 16 16 13 F 40 40 30 X 12-REA40 12-REA32 12-REA25 Rc, NPT, G 1/8 Rc, NPT, G 1/8 Rc, NPT, G 1/4 70 60 46 M26 x 1.5 M26 x 1.5 M32 x 2.0 21 17 15 50 40 34 19 15 13 150 124 111 182 156
, 50, 100, 500, 1000, 5000 ms Enclosure IP40 Environment Withstand voltage 1000 VAC for 1 minute between terminals and housing Insulation resistance 50 M or more between terminals and housing (with 500 VDC megger) Ambient temperature range Operation: -5 to 50 oC, Storage: -10 to 60 oC (No condensation or freezing) Operating humidity range Operation, Storage: 35 to 85%RH (No condensation)
5 10 15 4 6 10 15 10 12 19 27 11.5 13.9 22 31 Variation Action Mounting Note 2) Bore size (mm) Mounting Series Bore size (mm) Standard stroke (mm) 5, 10, 15 (20) Note 1) Series Action Standard stroke (mm) 5, 10, 15 5, 10, 15 5, 10, 15 5, 10, 15 4 6 10 16 4 6 10 15 Basic Flange Foot Clevis Trunnion Panel mount type, Embedded type Single acting, Spring return Double acting, Single rod 5, 10
14 10 14 12 16 20 24 27 38 41 51 37 41 50 41 45 57 42 43 53 72 78 12.5 15.9 12.5 15.9 13.6 17 15.8 19.2 19.6 20.9 21.3 24.5 20.9 21.3 24.5 20.9 21.3 24.5 20.9 21.3 24.5 24 27.2 13.8 15.6 13.8 15.6 16 17.8 20.4 2.5 4 1.6 1.8 8 5 10 13.5 3 4 2.6 2.3 Applicable tube L1 M 6 4 6 10 5.8 10 15 3.3 H1 12 d 6 8 14 6.6 12 5.3 17.4 16 22.2 A L2 23 H2 25.6 10 7.5 6.8 26 Connection thread 27.5 17 7.6
-20 -20 10 0 0 0 0 5 10 15 20 25 0.2 0.3 0.4 0.5 Supply pressure [MPa] Suction flow rate [L/min (AMR) ] The flow characteristics curve shows the relationship between the vacuum pressure and the suction flow of the ejector.
20, 25 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 Rod end thread Female thread 32, 40 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Rod end thread tolerance JIS class 2 50 to 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 +1.0 0 Stroke length tolerance When stroke exceeds the standard range, refer to page 7-6-121.
Refer to back page 50 for Safety Instructions and pages 3 to 9 for 3/4/5 Port Solenoid Valve Precautions.
AS321FE AS331FE AS421FE AS431FE Model 8 10 6 8 10 12 12 10 6 8 10 Tubing O.D.
Applicable model AW40-06 AW40 AW30 AW20 AW10 Accessory Bracket assembly Note 1) AR30P-270AS AR30P-260S G36-10-01 GC3-10AS G36-2-01 GC3-2AS AD38 AD38NNote 6) AR40P-270AS AR40P-260S G46-10-02 GC3-10AS G46-2-02 GC3-2AS AD48 AD48NNote 6) AR40P-270AS AR40P-260S G46-10-02 GC3-10AS G46-2-02 GC3-2AS AD48 AD48NNote 6) AR10P-270AS AR10P-260S G27-10-R1 G27-10-R1 Note 3) AW20P-270AS AR20P-260S G36-10
, 50, 100, 500, 1000, 5000 ms Enclosure IP65 Environment Withstand voltage 250 VAC for 1 minute between terminals and housing Insulation resistance 2 M or more between terminals and housing (with 50 VDC megger) Ambient temperature range Operation: -5 to 50 oC, Storage: -10 to 60 oC (No condensation or freezing) Operating humidity range Operation, Storage: 35 to 85%RH (No condensation) Standard
, 50, 100, 500, 1000, 5000 ms Enclosure IP65 Environment Withstand voltage 1000 VAC for 1 minute between terminals and housing Insulation resistance 50 M or more between terminals and housing (with 500 VDC megger) Ambient temperature range Operation: -5 to 50 oC, Storage: -10 to 60 oC (No condensation or freezing) Operating humidity range Operation, Storage: 35 to 85%RH (No condensation)
M6 x 1 Depth 7.5 39 50 0 77 74 59 155 128 143 3/4, 1 74 46 06 10 06 10 90 M6 x 1 Depth 7.5 39 50 0 77 74 59 175 128 3/4, 1 46 06 10 107 06 10 94 M6 x 1 Depth 7.5 39 50 0 77 74 59 175 128 3/4, 1 46 06 10 111 5 Soft Start-up Valve AV2000/3000/4000/5000 Modular F.R.L.
pressure: 0.5 MPa 50 10 20 0.15 0.3 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Effective area (mm2) Effective area (mm2) Effective area (mm2) 40 0.6 0.1 0.2 30 0.4 5 10 20 0.05 0.1 0.2 10 0 Number of needle rotations 5 10 0 0 0 Number of needle rotations 5 10 0 0 Number of needle rotations 10 20 15-9-68 Dual Speed Controller for Low Speed Operation With One-touch
For detecting fine pressures, warm up the product for 10 to 15 minutes. Check if the product satisfies the specified accuracy after 10 minutes warm up time.
If an instantaneous flow of 10 L/min continues for 5 minutes, the accumulated flow will be 10 x 5 = 50 L. Accumulated pulse output A type of output where a pulse is generated every time a predefined accumulated flow passes. It is possible to calculate the total accumulated flow by counting the pulses. Outputs a value proportional to the flow rate.