ZR IN side, OUT side (/min (ANR)) Weight (g) Model ZM ZFC100-04 4 10 11.5 ZFC100-06 6 20 ZH Metric size ZFC200-06 6 30 21.5 ZU ZFC200-08 8 50 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ZFC101-03 5/32" 10 11.5 ZL ZFC101-07 1/4" 20 Inch size ZFC201-07 1/4" 30 ZY
Air temperature (C) 60 20 10 0 10 30 40 50 Correction factor 0.94 1.08 1.06 1.04 1.02 0.98 0.97 0.95 Features 2 Direct Operated 2 Port Solenoid Valve for Air Series VCA Series VC How to Order Valves (Single Type) VC A 2 1 1 G 3 02 For air Option Series None Foot type bracket Nil F 2 3 4 Class 2 Class 3 Class 4 When only brackets are required, refer to Table 2 below.
/8 1/4 H 41 45 45 50 H1 5 6 6 8 20 0 0.033 0 0.033 0 0.033 0 0.039 20 26 26 32 M10 X 1.25 25 M10 X 1.25 M14 X 1.5 32 40 Boss-cut Dimensions for Other Mounting Brackets Bore ZZ 106 110 112 141 Add 3mm to each ZZ dimension of the standard style (double acting/single rod) on p.1.4-10 to 1.4-18. 20 Auto Switch Position Basic Low friction 25 CM2QB20SCM220A, #1 CM2QB25SCM225A, #1 CM2QB32SCM232A
Option L . 10-1 10.1 SAFETY INSTRUCTIONS FOR USE . 10-1 10.2 SPECIFICATIONS . 10-1 10.3 MOUNT THE HEAVY DUTY AUTO DRAIN . 10-2 10.4 MAINTENANCE . 10-2 Chapter 11 Option R .11-1 11.1 SAFETY INSTRUCTIONS FOR USE . 11-1 11.2 EARTH LEAKAGE BREAKER SPECIFICATION . 11-1 11.3 CONNECTION OF POWER SUPPLY . 11-2 Chapter 12 Option T . 12-1 12.1 SAFETY INSTRUCTIONS FOR USE . 12-1 12.2 OPERATION / ERROR
Burst prssure Min. bending radius (mm) 10 15 20 27 35 10 15 23 27 35 20 to +60C (Water: 0 to 40C) (No freezing) Polyurethane Operating temperature Material Precautions How to Order Be sure to read before handling.
Local Area: (800) 258-9200-www.stevenengineering.com Nil Without bracket 1 4" One-touch fitting for One-touch fitting for 4 One-touch fitting for 6 One-touch fitting for 4 SYA7000 F1 With foot bracket (2 position single only) SYA3000 5 16" One-touch fitting for VR F2 With side bracket Series One-touch fitting for 6 One-touch fitting for 8 One-touch fitting for 8 One-touch fitting for 10
Rc 1/8 12 16-2-23 10 Series ZSE40/ISE40 Dimensions ZSE40(F)/ISE40 C4 C6 M5 32.3 20 30 2-4.5 12.8 8 28.15 22.15 MPa 44.3 30 OUT1 OUT2 SET 19 25.4 6.4 18.35 Atmospheric release port Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 600 (3000) Lead wire length 3.5 ForM5
PA07 . 17 4.6 Auto tuning modePr.PA08 . 18 4.7 Input signal automatic on selectionPD01 . 18 4.8 Parameter setting by MR Configurator2TM . 19 4.8.1 Parameter reading . 20 4.8.2 Parameter setting (Ex. Control mode change) . 20 5.
It takes 10 [ms] to switch the channel. CH.B Channel 10 [ms] 10 [ms] CH.A Time GND CH.SELECT terminal 10 [ms] 10 [ms] Disconnected Time 16-13-11 19 Technical Information 2-wire pressure switch connections 14 Voltage and current output pressure sensors 15 A 3-wire type switch is a switch that has an output line other than the positive and negative lines that supply the electricity.
LEC-OM08002 DC24V / / LECP6 Series 1. . 4 2. . 6 2.1. . 6 2.2. 7 2.3 . 8 2.4 (). 9 1. 9 2. 9 3. 9 4ON .10 5().10 6.10 3. .11 3.1. .11 3.2.12 3.3. .13 1 LECP6.13 2 DIN LECP6D.13 3.4.14 1.14 2.14 3.15 4. .16 4.1 CN1.16 4.2 CN2CN3:.16 4.3 CN4I/O .16 1.16 2.17 4.4 CN5I/O .17 5. CN1:.18 5.1 .18 5.2 .18 5.3 .19 (1) .19 1 - (2) .19 (3) .19 5.4 .20 1.20 2.21 3().22 6.
per branch: 20 m or less At 1.0 A per branch : 16 m or less At 1.5 A per branch : 10 m or less Branch cable length Input/ output point Input point: Max. 64/ Output point: Max. 64 (Changeable by switch settings) 1: Input terminals are not isolated from Power source. 2: Do not connect outside Power source to Input and Output terminals.
Series P 20m bundle m 100m bundle TUH1065 TUH0805 TUH0604 TUH0425 TUH1208 Model 10 8 6 4 12 O.D. mm 6.5 5 4 2.5 8 I.D. mm Black (B) White (W) Blue (BU) Translucent (N) Specifications Air Note 1) Fluid Max. operating pressure (at 20C) (68F) 1.0MPa (145 psi) Note 2) Min. bending radius mm 10 15 20 27 35 2R At a temperature of 20C (68F) bend the tubing into a U shape.
Series P 20m bundle m 100m bundle TUH1065 TUH0805 TUH0604 TUH0425 TUH1208 Model 10 8 6 4 12 O.D. mm 6.5 5 4 2.5 8 I.D. mm Black (B) White (W) Blue (BU) Translucent (N) Specifications Air Note 1) Fluid Max. operating pressure (at 20C) (68F) 1.0MPa (145 psi) Note 2) Min. bending radius mm 10 15 20 27 35 2R At a temperature of 20C (68F) bend the tubing into a U shape.
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 5 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low tank fluid level 1 CH1 abnormal high circulating fluid temp. 2 Reservation
H A G G RG RT RS B 296 305 C R310 R445 D 93 129 E 60 87 F 10 15 G 6 7 B 296 309 C R390 R495 D 93 129 E 60 87 F 10 15 G 6 7 B 299 307 C R350 R440 D 93 129 F 10 15 G 6 7 H 610 700 A 600 743 A 680 797 A 643 740 15 32 15 32 15 32 Y Note 2) Y Note 2) Y Note 2) X 558 to 573 685 to 708 X 518 to 533 558 to 581 X 541 to 556 595 to 618 15 32 15 32 15 32 558 to 573 685 to 708 518 to 533 558 to 581
URL http://www.smcworld.com -10 V to 10 V -20 mA to 20 mA for 2 hours each in direction X, Y and Z respectively (De-energized) 24 VDC Class2, 2 A 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 0 V to 10 V 0 mA to 20 mA Content Content Content 0 V to 10 V 0 mA to 20 mA 0 V to 10 V 0 mA to 20 mA
CN2 11 15 14 2 12 PF SG CR PP PG NP NG SD V24 SON LSN LSP ALM SG 3 12 13 9 10 7 8 20 17 11 LG 19 P5 4 OP 1 V+ 20 12 7 6 P5 LG MR MRR MD MDR SD SG 7 8 1 2 4 5 9 P5 LG MR MRR MD MDR SHD 7 8 1 2 4 9 P5 LG MR MRR MD MDR SHD Note 3) Detector 17 16 Plate 5 Note 2) Note 6) Be sure to connect the shielding wires to the ground plate inside the connector.
> r l ii_9N c]0 v tadiris:10 Bore size d32, 040, d50/FSEOB32, 40, 50 _ 2 1 ?q o 9 l l / 10i11) 20\22) M 1 0 . 2 E Min. lead wire bending radius: 10 rNole 4lTh I our shows an o.rendedpisron tod .Note Jl Lor ( lare arhro. olF roLcF -.os re p'o{deo onr o_ rFe oo qde, lNole 1l Dimensions for moders wlhoutan aulo sw ich ar61he same as the above.
Weight g (oz) Model IN side, OUT side ZFC100-04 4 10 (0.35) 11.5 (0.41) ZFC100-06 6 20 (0.70) Metric size ZFC200-06 6 30 (1.05) 21.5 (0.76) ZFC200-08 8 50 (1.75) ZFC101-03 5/32" 10 (0.35) 11.5 (0.41) ZFC101-07 1/4" 20 (0.70) Inch size ZFC201-07 1/4" 30 (1.05) 21.5 (0.76) ZFC201-09 5/16" 50 (1.75) Note 1) Flow rate when initial pressure drop is 0.003MPa (0.44psi) or less.
> r l ii_9N c]0 v tadiris:10 Bore size d32, 040, d50/FSEOB32, 40, 50 _ 2 1 ?q o 9 l l / 10i11) 20\22) M 1 0 . 2 E Min. lead wire bending radius: 10 rNole 4lTh I our shows an o.rendedpisron tod .Note Jl Lor ( lare arhro. olF roLcF -.os re p'o{deo onr o_ rFe oo qde, lNole 1l Dimensions for moders wlhoutan aulo sw ich ar61he same as the above.