Mounting: B (Basic Style), Bore Size: 63mm, Thread: TN (NPT), Stroke: 150mm, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Bore Size: 25mm, Port Thread: TN (NPT), Stroke: 150mm, Adjuster: w/o Adjuster, Function: Standard, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Applications that call for precise movement ranging from 10-150mm * typically require a cylinder and a precision guide. The MXS accomplishes this by integrating a cross roller bearing with a guide and two small air cylinders for compact force generation. The MXS is available in six sizes each with set stroke lengths and is standard with auto switch capability. Stroke adjustments are available
Bearing: L (Ball Bushing), Bore Size: 10mm, Thread: ø6-ø20 Bore: M Thread; ø25,32ø Bore: Rc 1/8, Stroke: 150mm, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
TYPE Class Instance Attribute Size Description Output 100 100 3 1 INT Position set-point Input 150 150 3 2 INT 2 bytes measured position, 2 bytes diagnostics Figure 16-1 Explicit Messaging 41 - IN20267 Installation and Handling 17. Air supply 17.1. Use clean air.
(dimension reduced by 12mm to 26mm) (mm) Series 40 25 16 MY2C MY2H MY2HT MY1C, MY1H 58 37 28 84 54 40 Mechanical Joint Rodless Cylinder/Cam Follower Guide Series MY2C MY2 C Cam Follower Guide Improved guide performance enhances dynamic load capacity over other P/A cylinder Long strokes 60 M 3 30 50 Series MY2C cylinder is now available in long strokes up to 5000mm.
3 Port Solenoid Valve SYJ300/500/700 Series Low Power Consumption (0.5W) Interchangeable with the NVJ and NVZ Vacuum Applicable Base Mounted/Body Ported Configurations P R O D U C T S Q Q Q Table of Contents Q Q Q Q Features & Benefits .pages 4-5 Q Preferred Option Program.page 7 Q Specifications.page 9 Q SYJ300 .pages 10-12 SYJ500 .pages 13-15 SYJ700 .pages 16-18 Q
. 150 Pilot Operated 2 Port Solenoid Valve VXD Series High temperature oil Heated water 5 C 6 D Dimensions/VXD2 /2 Body Material: C37, Stainless Steel Grommet (42) 40 U E 300 C VX2 For Heated water/ High temperature oil Full-wave rectifier VXK T f 2.6 B A VXD VXD IN OUT M VXZ Port size 2 x P I VXS b a J F 2 x 8.5 e d L K VXB VXE (D) VXP DIN terminal VXR U V E C Cable 6 to 12 G1/2 VXH (44
Body Material Aluminum Body Material Brass A A 2 x J 4 x J A A 2 x J 4 x J B C F B B C F B 1/8, 1/4, 3/8 1/8, 1/4, 3/8 1/8, 1/4, 3/8 1/8, 1/4, 3/8 C F C D E D E F D E D E Body Material: Aluminum [mm] Body Material: Brass [mm] Size Port size A B C D E F J 20 1/8, 1/4 11 36 6 34 46 1.5 5.3 30 1/4, 3/8 13 46 7 40 56 1.5 Size Port size A B C D E F J 20 1/8 52 24 9 36 64 1.5 6 20, 30 1/4, 3/8
Water 15% Ethylene Glycol Aqueous Solution Physical property value Physical property value Temperature Density r [kg/dm3] Specific heat C [J/(kgK)] Conventional units Density r [kg/dm3] Specific heat C [J/(kgK)] Conventional units Weight volume ratio c [kgf/L] Specific heat C [cal/(kgfC)] 5C 1.00 4.2 x 103 1.00 1 x 103 Weight volume ratio c [kgf/L] Specific heat C [cal/(kgfC)] 5C 1.02 3.91
SMC vacuum pad Search http://www.smcworld.com Catalogs ZP2 ES100-76 ZP3 ES100-100 Best Pneumatics Pad diameter Symbol 16 18 20 25 30 32 40 46 50 63 80 100 125 150 250 300 340 U C C C C C C MU EU AU C C C C C C C UM UT C ( ( CT C C B C C C C C Note) Note) J ( ( ( MB ( ZJ ( ( D C C C AN Note) Note) Note) MT ( ( ( W U H C C C C C C ( ( ( HT ( ( HB C C C C ( C C ( 30 x 50 ( HW U ( ( ( (
A (OUT) port A A
C J G5-S CV MVGQ Applicable cable (Heavy-duty cord) Applicable to cable O.D. of 6.8 to 11.5.
DC Specification Temperature rise (C) Note) Temperature rise (C) Note) Model Power consumption (W) 45 45 60 Model Power consumption (W) 45 45 60 VX21 VX22 VX23 VX21 VX22 VX23 4.5 7 10.5 4.5 7 10.5 AC Specification AC Specification Apparent power (VA) Holding 19 16 43 35 62 52 Apparent power (VA) Holding 22 18 46 38 64 54 Temperature rise (C) Note) Temperature rise (C) Note) Model Model Inrush
AT O R S E R I E S NAL NAL800-N12 (1 14 NPT) NAL800-N14 (1 12 NPT) NAL900-N20 (2 NPT) T E C H N I C A L SPECIFICATIONS D I M E N S I O N S L U B R I C AT O R NAL800 NAL900 Max Supply pressure 1.5MPa / 220PSI Max Operating Pressure 1MPa / 145PSI Operating Temp Range 5~60C /40~140F Recommended lubricant Turbine oil #1 (ISO VG32) Bowl Polycarbonate Pipe Size 114, 112 2 Min Flow for Oil Drip
Circulating Fluid Typical Physical Property Values Ethylene Glycol Solution 20% Temperature [C] Density [kg/m3] Specific heat C [J/(kgK)] 10 1.03 x 103 3.93 x 103 20 1.03 x 103 3.95 x 103 30 1.02 x 103 3.97 x 103 40 1.02 x 103 3.98 x 103 50 1.01 x 103 4.00 x 103 60 1.01 x 103 4.02 x 103 Water Density g: 1 x 10 3 [kg/m 3] Specific heat C: 4.2 x 10 3 [J/(kg K)] 6 Thermo-con/ Rack Mount Type
SQ Flow Characteristics at the Number of Manifold Stations (Operated individually) VQ0 Passage/Stations Station 1 Station 5 Station 10 Station 15 Model VQ4 5.9 0.23 1.5 6.2 0.19 1.5 6.8 0.31 1.8 7.0 0.38 1.9 5.9 0.23 1.5 6.2 0.19 1.5 6.8 0.31 1.8 7.0 0.38 1.9 5.9 0.23 1.5 6.2 0.19 1.5 6.8 0.31 1.8 7.0 0.38 1.9 C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv C [dm3/(sbar)] b Cv
Indication Item Setting and selection Setting range [High] Set the temperature range of the circulating fluid SP. +0.1 C to +10.0 C +1.0 C Upper/lower temperature limit (1) High/ Low [Low] Set the temperature range of the circulating fluid SP. -0.1 C to -10.0 C -1.0 C TEMP READY signal is output when the set time has passed after the circulating fluid temperature rises/drops within the