JAS Series How to Order Port size M3 M3 x 0.5 M5 M5 x 0.8 U10 10-32UNF JAS L E A 04 M5 JAS L E A S 04 01 Seal method Type L Elbow Nil Without sealant S With sealant Control type1 Port size E Meter-out S Meter-in 01 1/8 1 Meter-out and meter-in types can be visually identified by the color of the knob.
1 Thread size M5 01 02 03 04 M5 x 0.8 R R R R 1 8 1 4 3 8 1 2 M5 port only Note 1) AS221: Electroless nickel plated Note 2) AS221: Steel Note 3) Meter-in type: Black zinc chromated 15-9-8
Model Pressure range *1 Indication unit Connection thread Note MPa Port size 01 Rc1/8 02 Rc1/4 R1/8 R1/4 G46-7-02-SRB 0 to 0.7 R1/4 G46-10-02-SRB 0 to 1.0 G46-4-01 to 02-SRB 0 to 0.4 MPa Set pressure range: 0.05 to 0.69 MPa 02 WR110 X215 *1: Do not apply more pressure than the max. pressure displayed. It may cause a malfunction.
(M3 thread) (It is recommended to ground with resistance of 100 ohms or less) Accessories Hexagon socket head cap screw (M3 x 30): 2 pcs. Connects the SI unit and the valve manifold. Seal cap: 1 pc.
Nil Metric thread (M3, M5) Rc NPT G N F Bore size Bore size Applicable series M3 M5 01 02 03 04 M3 x 0.5 M5 x 0.8 1/8 1/4 3/8 1/2 AS1000 AS1000 AS2000 AS2000, 3000, 4000, 5000 AS3000, 4000, 5000 AS4000, 5000 650 A
LCD Readout Digital Pressure Switch Series ZSE3/ISE3 How to Order Piping specifications Operating pressure range Single mounting R 1/8 Note 1) Nil L 01 T1 0 to 0.98 MPa 0 to 98 kPa Single mounting NPTF 1/8 Note 1) Note 1) M5 x 0.8 female threaded.
ASN AQ ASV Flow Rate and Sonic Conductance Symbol AK AS221F-01 AS121F-M5 AS221F-02 AS321F AS421F Model Tubing O.D.
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Piping: R1/8 w/M5 Female Thread, Output Specification: NPN Open Collector 2 Outputs+Copy Function, Unit Specification: -, Option: -, Calibration Certificate: -, Lead Wire: -
Rated Pressure Range: 0.00 to -14.69 psi, Piping: R1/8 w/M5 Female Thread, Output Specification: NPN Open Collector 2 Outputs+Copy Function, Unit Specification: -, Option: -, Calibration Certificate: -, Lead Wire: -
Rated Pressure Range: -14.50 to 14.50 psi, Piping: R1/8 w/M5 Female Thread, Output Specification: NPN Open Collector 2 Outputs+Copy Function, Unit Specification: -, Option: -, Calibration Certificate: -, Lead Wire: -
Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
36 132 50 41 200 74 60 230 74 60 271 86 70 22 36 110 180 544 612 873 JIS Symbol 1 4 1 2 2 Construction/Parts/Dimensions ANA1-01 to 06 Sound absorbing Case material (PFV ) End plate Hexagonal flats ANA1-06: PP How to Order Cover ANA1-10 to 20 Sound absorbing material Body Tension bolt End plate A1 03 AN Port size Symbol Connection Port size 1 8 01 1 4 3 8 1 2 3 4 02 03 04 06 10 12 14 20 (
ZSE3 ISE3L ISE3 (Vacuum) (Positive pressure 100 kPa) (Positive pressure 1 MPa) Rated pressure range 0 to -101 kPa 0 to 98 kPa 0 to 0.98 MPa Min. display unit 1 kPa 0.01 MPa Applicable fluid Air, inert gases and incombustible gases Max. operating pressure 200 kPa *1 1 MPa Power supply voltage 12 to 24 VDC 10%, ripple (P-P) 10 or less (Protected against inverse connection) Current consumption
Applicable model Regulator Series IR2000 Series VEX1A B33 etc In the case of multiple pressure control, consider using series ITV or the E-P HYREG series VY, which can simplify your system.
Regulator Options None Nil 1348112 K40-MP1.0-01S K50-MP1.0-02S K40-MP0.4-01S K50-MP0.4-02S K40-MP1.0-N01S K50-MP1.0-N02S K40-MP0.4-N01S K50-MP0.4-N02S 1348110A B Regulating pressure range Bracket 7~120psi 7~45psi 0 1 ARX20 mm Nil F ARX21 mm Nil F Thread type G Pressure gauge Rc(PT) NPT G(PF) Nil N F ARX20Nmm ARX21Nmm P Port size Panel nut 1/8 1/4 01 02 Option combination numbers Panel nut