Bore Size: 16mm, Stroke: 30mm, Adjuster: B (Shock Absorber), Magnet: Magnet and Rail, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal
Bore Size: 16mm, Stroke: 30mm, Adjuster: B (Shock Absorber), Magnet: Magnet and Rail, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)
Specification: 11 (Clean Type, Vacuum Suction), Bore Size: Ø16, Stroke: 30mm, Adjuster: H (Without Adjuster)
Bore Size: 16mm, Stroke: 30mm, Adjuster: Rubber Stopper, Magnet: Magnet and Rail, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
The MXQ precision slide is ideal for applications requiring closely held parallelism and perpendicular specifications. The table and bearing guide are integrated into one precisely machined part made of hardened stainless steel. This minimizes tolerance stack-up associated with multiple part assemblies, and affords height tolerances of +/-0.05mm. The bearing is a recirculating linear guide
The MXP is ideal for applications that require high precision movement in short travel situations. The precision slide table has a machined guide with very tight tolerances that operates in conjunction with highly accurate recirculating ball bearings. This slide is capable of achieving parallelism within 0.02mm and non-rotation accuracy as low as 0.03 degrees. Two of the mounting surfaces
The MXQ precision slide is ideal for applications requiring closely held parallelism and perpendicular specifications. The table and bearing guide are integrated into one precisely machined part made of hardened stainless steel. This minimizes tolerance stack-up associated with multiple part assemblies, and affords height tolerances of /-0.05mm. The bearing is a recirculating linear guide
Bore Size: 8mm, Port Thread Type: M Thread (ø6-ø16); Rc (ø20-ø25), Adjuster Position Set: L (Left Side), Stroke: 20mm, Adjuster: C (Both Side Adjusters/Metal Stoppers)
Bore Size: 8mm, Symmetric Type: Standard, Stroke: 20mm, Adjuster: C (Both Side Adjusters/Metal Stoppers)
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Built-in
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~70, Operating Pressure(MPa): 0.05~1, Cushion: Air cushions on both sides + with damper cushions, Specification: Built-in
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Support bracket: None, Auto Switches: Without auto switch,
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Support bracket: None, Auto Switches: Without auto switch,
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number