Vibration resistance: No malfunction occurred in a test ranging between 45 to 2000 Hz, when the actuator was tested in both an axial direction and a perpendicular direction to the lead screw. (The test was performed with the actuator in the initial state.)
Vibration resistance: No malfunction occurred in a test ranging between 45 to 2000 Hz, when the actuator was tested in both an axial direction and a perpendicular direction to the lead screw. (The test was performed with the actuator in the initial state.) Note 5) Only when the motor option, "with lock", is selected.
42 19 Data P GD GK GL GQ GR H I J K L M N O Q R S Bore size (mm) 20 25 32 40 M8 x 1.25 depth14 80 5.5 60 3.5 93 M5 x 0.8 54 4 4 35 105 50 25 M6 x 1 14 26 M10 x 1.5 depth18 95 9 70 4 103 M5 x 0.8 62 7 7 40 125 60 32 M8 x 1.25 14 31 M10 x 1.5 depth18 95 9 70 4 104 Rc 1/8 Rc 1/8 62 7 7 40 125 60 32 M8 x 1.25 13 38 M12 x 1.75 depth 21 115 11 82.5 4 115 67 8 8 45 150 75 38 M8 x 1.25 14 47 WH
0.99 5 to 80 Replaceable P . 302 Straight type IDFB IDH ID IDG Nominal IDK 120 m 400 SFB20 (Strainer) P . 303 Sintered metallic element ( ) AMG AFF AM Straight type AMD AMH SFB30 P . 306 45 0.99 AME AMF 0.01 m Filtering efficiency 99.99% ( ) ZFC Nonreplaceable 5 to 120 Membrane element ( ) Multiple disc type SF SF SFD SFC10 P . 309 240 0.99 LLB AD GD Case/Cover material: Aluminum alloy
67.5 9 2-M5 0.8 with depth 7.5 25 2-M6 1.0 73 29 87 71 27 13.5 60 35 6 12 4.5 30 12 14.5 46 70.5 9 2-M5 0.8 with depth 7.5 32 2-M6 1.0 94 37 100.5 92 35 17.5 75 45 8 16 4 30 16 18.5 56 80.5 10 Symbol Z Stroke 10.20 30.40.50 Bore size (mm) 75 100 15 20 25 32 25 35 45 55 30 40 60 60 30 40 60 60 40 50 70 70 13 Compact Type Dual-Rod Cylinder Series CXSJ Proper Auto Switch Mounting Position
Description AQ2000 AQ3000 AQ5000 AQ1500 AQ1510 Valve 30093 NBR 30073 30053 30063 30083 r O-ring 9 x 7 x 1 JIS B 2401P-7 NBR CA40-1601 CA50-1602 30066 t Dimensions AQ1500/1510 AQ2000/3000/5000 3-port size (Mounting hole) 3-port size L1 L2 L3 L4 L5 L6 L7 L8 L9 D L1 L2 L3 L4 Model Port size AQ2000 Model Port size 1 8 1 4 M5 x 0.8 AQ1500 23 20 14 3 12.5 12 15 5.5 6.5 3.1 45 40 10 45 , 3 8 1 4
Flow Characteristics/Weight Flow characteristics C [dm 3/(s bar)] b Cv C [dm 3/(s bar)] b Cv 1 2 (P A) 2 3 (A R) Valve model Weight (g) Pilot port size Type of actuation Port size SYJA512-M5 SYJA522-M5 0.12 0.18 0.39 0.45 0.47 0.66 0.14 0.18 0.45 0.45 N.C. 0.53 0.66 M5 x 0.8 Body ported 45 N.O. M5 x 0.8 SYJA514-01 0.32 0.46 1.1 0.32 0.41 1.2 75 (Without subplate 45) Rc 1/8 N.C.
45 37.4 28 4.5 1.6 41.6 22 50 9 134.9 60 (Piping port) Rc 1/4, 3/8 30.7 26.1 : With light/surge voltage suppressor PE 7 DIN terminal (D, Y) 1(P) 3(R) 3.5 Applicable cable O.D.
(Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature.
VH421-02 to 06 VH431-02 to 06 3 (Exhaust center) Rc 3/4: 58 2 position 3 position 3 4 2 1 Flow direction 4(B) 90 45 45 Flow direction 2 (A) Flow direction 4(B) Flow direction 2 (A) VH422-02 to 06 VH432-02 to 06 2 (Position) N Rc 3/4: 185 1 2 VH6 VH600-06/10 9.7 3 (Exhaust center) 3/4, 1 Rc 1: 194 3 4 5-8-7 2 Series VH How to Order VH 2 0 1 02 1(P) port location Hand valve R L 1(P) port 180
PNP open collector 2 outputs Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l Panel mounting Specifications for Display Unit PF2D300/301 Model 0.25 to 4.5 l/min 1.3 to 21.0 l/min 2.5 to 45 l/min Flow rate measurement range Note 1) 0.25 to 4.5 l/min 1.3 to 21.0 l/min 2.5 to 45 l/min Set flow rate range Note 1) 0.05 l/min 0.1 l/min 0.5 l/min Minimum set unit Note 1) Accumulated
67.5 9 2-M5 0.8 with depth 7.5 25 2-M6 1.0 73 29 87 71 27 13.5 60 35 6 12 4.5 30 12 14.5 46 70.5 9 2-M5 0.8 with depth 7.5 32 2-M6 1.0 94 37 100.5 92 35 17.5 75 45 8 16 4 30 16 18.5 56 80.5 10 Symbol Z Stroke 10.20 30.40.50 Bore size (mm) 75 100 15 20 25 32 25 35 45 55 30 40 60 60 30 40 60 60 40 50 70 70 13 Compact Type Dual-Rod Cylinder Series CXSJ Proper Auto Switch Mounting Position
t41x1.5 M 1 8 X 1 . 5 M 1 8 X l . 5 M22X1.5 t\r26x1.5 27 v4 42 20 45 1 5 3 8 60 I 80 42 100 2t5 52 43 59 v. 30 ls 46 1 0 21 50 168 0 70 I 90 50 1 1 0 58 237 58 52 1 5 66 n 6 ?
A + Stroke DL LL DM MO HR W 32 45 25 15 22 15 33.5 DM With front lock 40 52.5 29 21 26 19 38.5 50 59 29.5 21 24 19 45 63 64 28.5 21 25 19 50 63 cylinder tube configuration Q F A + Stroke B + Stroke Rod end male threads (mm) With rod end male threads H1 Bore size (mm) L1 C1 X H1 32 20.5 23.5 M14 x 1.5 28.5 40 20.5 23.5 M14 x 1.5 28.5 50 26 28.5 M18 x 1.5 33.5 C1 63 26 28.5 M18 x 1.5 33.5 X
M8 x 30 Tightening torque 16.91.7Nm M8 x 20 M5 x 45 Tightening torque 16.91.7Nm Pulley cover mounting process Pulley cover Pulley cover mounting process TP-M3 x 5 TP-M3 x 5 1. Mount the pulley cover using thin head screws. Confirm there is no rattle on the pulley cover. 21 Electric Actuator/Maintenance Guide 6 Be sure to read before handling.
,|e 4 = \bh unit only (N\6A31 14 only; see page 7) 5 = Foot mounting;pipe tap in body hing 0O = Manilold mounting (NVSA 3114) 01 = 1/8" NPrF 0 SA 31 15, 3125) 02 = 1/4" NPTF (N\6A 3t 15, 3t25) 03 = 3/8" NPTF N\ISA 3135) (X = 1/2" NPTF (N\^sA 31 35, 31 45) 06 = 3/,1" NPTF (N!6A 3145) DIBECTIOI{ALAIBVALYE DIMENSIONS/PARTS LIST SERIES NVSA 3115 NVSA 3115 oPttot{a!l frg. lasE axl 338.
75 114 145 213 281 347 than is the case with more flexible smaller rods; therefore, the use of oversized 3200 16 41 67 103 130 194 261 329 4000 13 38 63 94 119 175 240 310 rods should not be considered a remedy against excessive side loads. 5000 9 34 60 87 110 163 225 289 6000 5 30 56 82 102 152 208 274 8000 4 26 50 76 93 137 188 245 10 3 21 45 70 89 125 172 222 12000 17 41 65 84 118 155
to 700 25 19.5 9 6 30 7 5.5 28.5 36 38 51 51.5 55 19 18 22 12 200 to 1000 32 21 11 8 35 9 7.5 23 32 47 54.5 51.5 56 21 20.5 24 16 200 to 1000 40 MM LZ LY LX LT S NN ND NF NE P NB ZZ LS NA Y N WH X Bore size (mm) 55 41 40 5.5 M22 x 1.5 15.0 13 33.5 30 265 26 9 22 20 232 M8 x 1.25 192 1/4 20 55 46.5 40 5.5 M24 x 1.5 19.6 17 37 36.9 270 32 9 27 5.8 to 8.8 20 233 M10 x 1.25 193 1/4 25 60 53 45
P.40 P.45 16 point I/O unit Wires two of 16 point I/O signals once separated by the branch unit to each connecting equipment via terminal block. DIN rail mount type and box mount types are available. 8 point I/O unit Wires two of 16 point I/O signals once separated by the branch unit to each connecting equipment via terminal block. DIN rail mount type and box mount types are available.
VH301-N02, N03 VH311-N02, N03 3 (Exhaust center) 1/4" 17(0.9) Exhaust center VH302-N02, N03 VH312-N02, N03 2 (Position) 2 1 1.56 (0.71) (A) 2 (B) 4 VH3 1/4", 3/8" VH320-N02, N03 VH330-N02, N03 3 (Closed center) 3/8" 20(1.1) 1 (P) 3 (R) VH321-N02, N03 VH331-N02, N03 3 (Exhaust center) VH322-N02, N03 VH332-N02, N03 2 1 3 4 2 (Position) VH400-N02 to N06 VH410-N02 to N06 3 (Closed center) 1/4" 45