2,088 2,090 IDFC60/70/80/90 Series 7-2 IDX-OM-W095 7.3 Port size Compressed air inlet Compressed air outlet Port size B A E D G F C P J M N H K O L mm A B C D E F G H J K L M N O P IDFC60 R1 307 745 605 161 405 681 71 330 704 355 126 94 46 12.5 IDFC70 R1-1/2 342 890 825 176 480 905 68 365 849 390 81 20 IDFC80 R2 438 957 863 169 480 958 219 78 100 11.0 463 916 485 170 IDFC90 13 mm IDFC80
Coefficient factors Inlet air temperature (oC) 5 to 25 30 35 40 45 50 55 60 65 1.42 1.15 1.00 0.71 0.62 0.50 0.40 0.33 0.21 Inlet air pressure (MPa) 0.3 0.4 0.5 0.6 0.7 to 1.6 0.71 0.75 0.82 0.89 1.00 Ambient temperature (oC) 2 to 25 30 35 40 45 1.0 0.85 0.80 0.73 0.62 Calculation example: The air flow capacity when the dew point of IDFA60 is set to 10 oC under the following conditions <
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 40 (5 to 40 L/min), Return Unit Components: S (w/Flow Adj.
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: J (OUT 1: Analog 1 to 5V; OUT 2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F)
Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 05 (5 Stations), Piping: U (U Side: Open; D Side: Closed), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 40 (5 to 40 L/min), Return Unit Components: W (w/Flow Adj.
Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: P (w/o Flow Adj.
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: K (OUT 1: Analog 4 to 20mA; OUT 2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F), Bracket: R (Bracket)
Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 40 (5 to 40 L/min), Return Unit Components: W (w/Flow Adj.
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F), Bracket: R (Bracket), Calibration Certificate: A (Calibration Certificate
Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: P (w/o Flow Adj.
I/O and actuator cables are also identical to the standard LEY Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s ²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with incremental A/B phase encoder
Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with incremental A/B phase encoder
Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with incremental A/B phase encoder
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: KT (OUT1: Analogue 4 to 20 mA - OUT2: Analogue 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature: °F),
I/O and actuator cables are also identical to the standard LEY Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s ²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with incremental A/B phase encoder
Body sizes: 16, 25, 40; Maximum work load: 100 kg (horizontal); 46 kg (vertical); Maximum speed: 800 mm/s (16mm lead, size 40); Maximum acceleration: 10, 000 mm/s²; Stroke range: 30 to 500mm in 50mm increments; Positioning repeatability: ±0.02mm; Motor type: 24 VDC step motor with incremental A/B phase encoder
Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: W (w/Flow Adj.
Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: W (w/Flow Adj.
Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: W (w/Flow Adj.