Type of Actuation: 2 Position Double, Manifold Type: Base Mounted Non Plug-in Single/Stacking Base, Plug-in Stacking Base, Pilot: Internal Pilot, Specifications: Power Saver, Voltage: 24VDC, Electrical Entry: Grommet Lead Wire 0.6m, Lead Wire Length: None, Surge Suppressor: Light & Surge Suppressor, Manual Override: Push-turn Locking Slotted Style, A, B Port Size: -, Thread: -, Option: -
Function: 2 Position Single, Piping: Base Mounted, Pilot: Internal Pilot, Voltage: 24VDC, Specifications: +COM, Lead Wire: Grommet Lead Wire 0.6m, Surge Suppressor: Light & Surge Suppressor, Manual Override: Push-turn Locking Slotted Style, Port Size: -, Thread: -, Option: -
Function: Normally Closed, Piping: Base Mounted, Body Option: Common EXH, Specifications: Standard, Rated Voltage: 24VDC, Lead Wire: Grommet Lead Wire 0.6m, Surge Suppressor: Light & Surge Suppressor, Manual Override: Screwdriver Operated Style, Port Size: -, Bracket: -, CE-Compliant: -
Function: Normally Closed, Piping: Base Mounted, Body Option: Individual EXH, Specifications: Power Saver, Rated Voltage: 24VDC, Lead Wire: Grommet Lead Wire 0.6m, Surge Suppressor: Light & Surge Suppressor, Manual Override: Screwdriver Operated Style, Port Size: -, Bracket: -, CE-Compliant: -
Function: Normally Closed, Piping: Base Mounted, Body Option: Individual EXH, Specifications: Standard, Rated Voltage: 24VDC, Lead Wire: Grommet Lead Wire 0.6m, Surge Suppressor: Light & Surge Suppressor, Manual Override: Screwdriver Operated Style, Port Size: -, Bracket: -, CE-Compliant: -
Type of Actuation: 2 Position Single, Manifold Type: Base Mounted, Pilot: Internal Pilot, Specifications: Standard, Voltage: 24VDC, Electrical Entry: Grommet Lead Wire 0.6m, Lead Wire Length: None, Surge Suppressor: Light & Surge Suppressor, Manual Override: Push-turn Locking Slotted Style, Port Size: -, Thread: -, Option: -
Type of Actuation: 1 (2 Position Single), Manifold Type: 40 (Base Mounted Non Plug-in Single/Stacking Base, Plug-in Stacking Base), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: H (Grommet Lead Wire 0.6m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Slotted Style)
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Mounted Non Plug-in Single/Stacking Base, Plug-in Stacking Base), Pilot: Internal Pilot, Specifications: T (Power Saver), Voltage: 5 (24VDC), Electrical Entry: H (Grommet Lead Wire 0.6m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Slotted Style)
Type of Actuation: 1 (2 Position Single), Manifold Type: 40 (Base Mounted Non Plug-in Single/Stacking Base, Plug-in Stacking Base), Pilot: Internal Pilot, Specifications: T (Power Saver), Voltage: 5 (24VDC), Electrical Entry: H (Grommet Lead Wire 0.6m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Slotted Style)
Q 16 46.5 30.4 21.5 6 M10 A10 14 3 10 x 1 102.6 68.6 23 F2 Width across flats N 20 140.6 78.6 51 30 150.6 88.6 40 186.6 98.6 77 50 196.6 108.6 N S U F GN GS 20 25 57.6 39.8 29 Construction p. 118 J K ZP R U 04 06 08 12 12 M8 x Buffer Assembly p. 125 3.5 10 103.1 69.1 1.25 23 20 141.1 79.1 51 30 151.1 89.1 40 187.1 99.1 77 50 197.1 109.6 32 58.1 40.3 29.5 10 140.6 72.6 20 137.6 82.6 30 147.6
Allowable driving force (Fn) (n = 1, 2, 3) W + WB WV P PV W + WB > WV P > PV Determination of allowable load weight & pressure High Precision Guide Type REAH F1 = x (W + WB) x 9.8 Horizontal Inclined Vertical F2 = (W + WB) x 9.8 x (cos + sin) (See page 63 for vertical operation.)
F1 = x (W + WB) x 9.8 Horizontal F2 = (W + WB) x 9.8 x (COS + SIN) Inclined F3 = (W + WB) x 9.8 x ( + 1) Vertical Refer to the allowable driving force table for (Fn) of data A. (For maximum load weight when loaded directly on the body, refer to page 10-2-68.)
F1 = x (W + WB) x 9.8 Horizontal F2 = (W + WB) x 9.8 x (COS + SIN) Inclined F3 = (W + WB) x 9.8 x ( + 1) Vertical Refer to the allowable driving force table for (Fn) of data A. (For maximum load weight when loaded directly on the body, refer to page 10-2-68.)
D 1.6 x P WB 20Data Inclined operation W + WB WV P PV W + WB > WV P > PV Allowable Driving Force (Fn) (n = 1, 2, 3) Determination of allowable load weight & pressure F1 = x (W + WB) x 9.8 Horizontal F2 = (W + WB) x 9.8 x (cos + sin) Inclined (Refer to page 8-15-12 for vertical operation.)
F1 = x (W + WB) x 9.8 Horizontal F2 = (W + WB) x 9.8 x (COS + SIN) Inclined F3 = (W + WB) x 9.8 x ( + 1) Vertical Refer to the allowable driving force table for (Fn) of data A. (For maximum load weight when loaded directly on the body, refer to page 10-2-68.)
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Load weight (kg) Dm1 -X 20m2 m3 Moment (Nm) Data M3=F3 x L3 F3 F2 M1=F1 x L1 F1 M2=F2 x L2 L2 L1 L3
bore size determination F3 D1.6 x ___ P WB Inclined operation W+WBWV PPV W+WB>WV P>PV Allowable driving force table (Fn) (n = 1, 2, 3) Determination of allowable load weight & pressure F1 = x (W + WB) x 9.8 F2 = (W + WB) x 9.8 x (cos + sin) F3 = (W + WB) x 9.8 x ( + 1) Horizontal Inclined Vertical (Refer to p. 14 for vertical operation.)
MY1B m2 m3 Moment (Nm) MY1M M1 = F1 x L1 F1 M2 = F2 x L2 M3 = F3 x L3 F3 F2 MY1C L2 L1 L3 MY1H 4. Accuracy Mechanically jointed rodless cylinders do not guarantee traveling parallelism. When accuracy in traveling parallelism and intermediate stroke position is required, please contact SMC sales representatives.
F2 P3 wSub-plate Thread type Port size Thread type Rc G Note) Symbol Port size 1/4 3/8 Nil F N T Symbol 1 2 NPT NPTF !1Gasket DXT172-7 !
F2: The force that is ceated by the port A pressure (PA) that passes through the feedback passage and acts on the spool surface, and the spring force. OFF state { A R1 (Exhaust air) P B (Supply air) F1 < F2 condition: See figure q. ON state { { Immediately after turning on F1 > F2: See figure e.