(mm) 4 6 Note) Weight (g) L Q M Model D D Urethane 4.4 10.6 4-applicable tubing KQ2TW04-00 KQ2TW06-00 10.4 12.8 9 13 18 20 8.7 9.9 16 17 8 KQ2TW08-00 15.2 23 11.1 18.5 25.6 17.7 20 10 KQ2TW10-00 18.5 26.5 12.8 21 40 28.4 33 12 KQ2TW12-00 20.9 28.5 13.9 22 57.4 45.4 39 Note) D: Max. diameter D 2-8 2-4.2 Different Diameter Cross: KQ2TX Applicable tubing O.D.
8 MB n (Same side) 2 (Different sides or Same side) 20 25 25 MB1 (n2) 2 (n2) 2 (n2) 2 25 + 55 n = 2, 4, 6, 8 20 + 55 n = 2, 4, 6, 8 25 + 55 n = 2, 4, 6, 8 n (Same side) D-A59W CA2 1 15 25 25 D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F59F 15 25 25 2 (Different sides or Same side) CS1 (n2) 2 (n2) 2 (n2) 2 15 + 55 n = 2, 4, 6, 8 25 + 55 n = 2, 4, 6, 8 25 + 55 n = 2, 4, 6, 8 n (Same side) C76 1 10 25
AL 14-2-31 32 Series AC How to Order AC 30 A F 03 D A KV 12R X465 Switch specifications F.R.L. unit Symbol A B C D Output specifications NPN output PNP output 1 to 5 V output 4 to 20 mA output Body size 20 25 30 40 50 55 60 Model combination Combination With digital pressure switch (Series ISE30) (12) Symbol Filter Regulator Mist Separator Air filter Lubricator Regulator Nil A B C D Note
Auto Switch Proper Mounting Height (Standard type) [mm] Auto switch model D-F5l D-J59 D-F59F D-F5lW D-J59W D-F5BA D-F5NT D-Y59l D-Y7P D-Y7lW D-Y7BA D-Z7l D-Z80 D-M9l D-M9lW D-M9lA D-A9l D-A9lV D-M9lV D-M9lWV D-M9lAV D-A5l D-A6l D-A59W D-Y69l D-Y7PV D-Y7lWV D-P3DWA D-P4DW D-G39 D-K39 D-A3l D-A44 Bore size Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht 32 24.5 23 27.5 23
or more 65st or more D-H7LF 20 to 64st 20 to 64st 10st or more 10st or more 75st or more 75st or more D-B5, B6, G5NT 15 to 74st 15 to 74st 10st or more 10st or more 75st or more 75st or more D-B59W 20 to 74st 20 to 74st 15st or more 15st or more 14 Series CNG Auto Switches/Proper Mounting Position and Mounting Height for Stroke End Detection D-C7, D-C8 D-G5NT Approx.
(per stroke) Model Weight (g) Dimensions (per stroke) Model Weight (g) Dimensions (per stroke) Model Weight (g) Lateral A 17 20 B 34 40.5 D 11 14.5 11.0 12.2 A 17 20 B 30 37 D 10 14 7.7 8.6 A 17 20 B 34 40.5 D 11 14.5 11.0 12.2 A 17 20 B 30 37 D 10 14 7.7 8.6 ZP3-Y015U:J3-B3 ZP3-Y015U:J6-B3 ZP3-Y015U:K3-B3 ZP3-Y015U:K6-B3 ZP3-Y02U:J3-B3 ZP3-Y02U:J6-B3 ZP3-Y02U:K3-B3 ZP3-Y02U:K6-B3 Note)
Hs Operating Range Applicable bore size (mm) Auto switch model 100 80 63 50 40 32 25 20 16 D-Z7/Z80 12 11.5 11.5 10.5 10.5 10.5 10 10 10 D-Y59/Y69/Y7P/Y7PV D-Y7W/Y7WV 10 9.5 8 7 6 6.5 7 7.5 7.5 D-Y7BAL 6.5 6 6 6 6 6 5 5 5 4 4 5 4 4 D-P5DWL Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted.
4 R 1/4 R 1/4 12 12 12 14 14 14 14 18 18 18 20 20 20 20 14 14 14 14 14 14 14 KNS-R01-075-4 KNS-R01-100-4 KNS-R01-090-8 KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 D 2 H1 A L1 Connection thread 57 &RXUWHV\RI6WHYHQ(QJLQHHULQJ,QF5\DQ:D\6RXWK6DQ)UDQFLVFR&$ *HQHUDO Series KN Sensing Heads Standard sensing head (mm) Model Nozzle size D Connection size L1 L2 Width across flats H1 H2
or more 65st or more D-H7LF 20 to 64st 20 to 64st 10st or more 10st or more 75st or more 75st or more D-B5, B6, G5NT 15 to 74st 15 to 74st 10st or more 10st or more 75st or more 75st or more D-B59W 20 to 74st 20 to 74st 15st or more 15st or more 14 Series CNG Cylinder with Lock Auto Switch Specifications Auto Switches/Proper Mounting Position and Mounting Height for Stroke End Detection
Auto Switch Proper Mounting Position for Stroke End Detection MY1CW 16, 20 MY1MW 16, 20 B A Reed switch D-A90(V), D-A93(V), D-A96(V) Solid state switch D-F9N(V), D-F9P(V), D-F9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) Mounting position 16 20 20 16 20 Mounting position Mounting position 16 A 70 90 93 73 94 A A 74 B 90 110 107 87 106 B B 86 Operating range Note) 11 7.5 6.5 8.5 6.5 Operating range
) D-F7/J79 D-F7V/F79F/J79C D-F7W/F7WV D-F79F/F7BAL/F7BAVL/F7NTL 20 to 63 Without indicator light 6.5 5.5 5 6 6 6 Reed switch 12, 16 32 to 63 4.5 4.5 5 5 D-M9/M9V D-F9W/F9WV D-F9BAL Solid state switch 5.5 5.5 5.5 6 20 to 63 With timer D-F7NTL Grommet (In-line) 5 5 5 D-P5DWL With pre-wire connector is available for D-F7NTL type, too.
D across flats D across flats NCA D-X Stroke A Stroke B SN + Stroke (A + B) 4-NT Depth ND 20LD + Stroke (A + B) Data ZZ + Stroke (A + B) Bore size (in) MM KK A AA B C D DD E EA EE G K R WF Y LD P PC ZZ SN 150 (1.5") 5/8 7/16-20 3/4 2.02 1 1/8 3/8 9/16 1/4-28 2 0.3 3/8 1.26 9/32 1.43 1 1.71 7.44 2.36 1.30 9.44 5.56 200 (2") 5/8 7/16-20 3/4 2.60 1 1/8 3/8 9/16 5/16-24 2 1/2 0.3 3/8 1.26 11
flats AA D across flats 4-NT Depth ND d + Adjustable range SN + Stroke ZZ + Stroke + Adjustable range Bore size (in) MM KK A AA B C D DD E EA EE G J JA K R WF Y LF P ZZ TN XT SN d mm 150 (1.5") 5/8 7/16-20 3/4 2.02 1 1/8 3/8 9/16 1/4-28 2 0.3 3/8 1.26 1.10 11/32 9/32 1.43 1 1.71 3 5/8 2.36 6.44 5/8 1 15/16 2 1/4 1.81 M16x1.5 200 (2") 5/8 7/16-20 3/4 2.6 1 1/8 3/8 9/16 5/16-24 2 1/2 0.3 3
/A6 D-A3/A44 D-G39/K39 D-A59W D-F59F D-B59W D-G5/K59 D-G5W/K59W D-G5BAL/G5NTL D-F5/J5 D-F5W/J59W D-F5BAL D-B5/B64 D-G59F D-F5NTL Bore size (mm) A A A A A A A A 32 15 19 21.5 25.5 26.5 17 15.5 18.5 Note) 40 16 20 22.5 26.5 27.5 18 16.5 19.5 50 16 20 22.5 26.5 27.5 18 16.5 19.5 63 19 23 25.5 29.5 30.5 21 19.5 22.5 80 23 27 29.5 33.5 34.5 25 23.5 26.5 100 26 30 32.5 36.5 37.5 28 26.5 29.5 Note
CDU Double Acting, Single Rod D-A9, D-A9V D-M9, D-F9W D-M9V, D-F9WV Bore size (mm) B W A W W B B A A 6 10 16 20 25 32 3.5 4.5 17.5 6.5 0.5 3.5 13.5 17.5 2.5(5) 7.5 0.5 16.5 2.5 3.5 7.5 12.5 16.5 1.5(1) 8 0.5 20 1.5 4 8 16 20 2(0.5) 10 2 24 0 6 10 20 24 4(1.5) 11 3.5 26.5 1.5 7 11 22.5 26.5 5.5(3) 12.5 4.5 27.5 2.5 8.5 12.5 23.5 27.5 6.5(4) Note 1) Figures in the table above are used as a
Minimum Auto Switch Mounting Stroke (mm) D-A9V D-A7 D-A80 D-A73C D-A80C D-F7W D-J79W D-F7BA D-F79F D-F7NT D-M9WV D-M9AV D-F7WV D-F7BAVL D-M9V D-F7V D-J79C D-M9 D-F7 D-J79 No. of auto switches mounted D-M9W D-M9A D-A7H D-A80H D-A79W D-A9 10 (5) 15 (10) 15 (5) 1 pc. 5 5 10 15 (5) 15 20 (10) 10 15 15 (10) 2 pcs. 5 10 15 15 (5) 20 20 (15) Note) The dimensions stated in ( ) shows the minimum stroke
1 Single Axis Electric Actuator High Rigidity Direct Acting Guide Series LJ1H Series LJ1H LJ1 LG1 LC1 LX LC6D/LC6C Switches Lead screw lead mm Mounting orientation Series Page Model Motor type Guide type Ground ball screw Rolled ball screw Slide screw 12 10 20 12 10 20 20 20 40 LJ1H10 LJ1H20 LJ1H30 LJ1H10 LJ1H20 LJ1H30 LJ1H10 LJ1H20 LJ1H30 LJ1H10 LJ1H20 LJ1H30 2 Horizontal 8 25 25 18 Standard
Auto Switches: Proper Mounting Positions and Mounting Heights for Stroke End Detection D-M9 D-M9W D-M9AL D-A9 D-M9V D-M9WV D-M9AVL D-A9V CHQ CHQ CHK 32 to 100 20 CHN Approx. U CHM 25 CHS CH2 Approx. U B A CHA B A Related Products D-F7 D-F7W D-J79 D-J79W D-A7 D-A7H D-A8 D-A8H D-F7V D-F7WV D-F7BA D-F7BAV D-F7NT D-F79F D-J79C D-A73C D-A80C 32 to 100 DApprox. U B A Approx.
D-F5BAL/F59F D-F5W/J59W CP95 ~ = NCM ~ = ~ = NCA D-X 20Proper Auto Switch Mounting Position Auto Switch Mounting Height Data D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL Auto switch model D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F59F D-A5 D-A6 D-A3 D-A44 D-G39 D-K39 D-A3 D-G39 D-K39 D-A44 D-A5 D-A6 D-A59W D-A59W D-F5NTL Bore size (mm) A B A B A B A B Hs Hs Hs Ht Hs Ht 74.5 125 0 0 2 2 4.5 4.5 9.5
D-F9P D-F9G D-F9H D-F9GL D-F9HL D-F9B D-F9NL D-F9PL D-F9BL N.O.