SMC Corporation of America
Elite Part Number Search
Search Results "VVEX4-2-6-B"

How to Order AS 2 2 0 1F G 01 06 W2D Flame resistant flat head screwdriver adjustable Body size 2 1/8, 1/4 standard 3 3/8 standard 4 1/2 standard Applicable tubing O.D.*1 Metric size 06 6 08 8 10 10 12 12 Elbow Control method 0 Meter-out 1 Meter-in *1 For selecting applicable tubing O.D., refer to the Model shown above.

IS2761-1103L2 220 VAC IS2761-1103L9 24 VDC 4 5 3 6 Dimensions 1.3: Power supply for neon light 4: Common 5: Normally closed 6: Normally open b point (4-5) becomes OFF. a point (4-6) becomes ON.

Example: Nut for JS40 2 Series JS Dimensions JS10, 16 M M U D J U F B G H C E P A Use a 4mm precision watch wrench to attach the JS10 male threads.

Start up procedure / Connecting to a computer . 5 2. 1 Preparation . 5 (1) Confirmation of product . 5 (2) Wiring . 5 (3) Installation of the Card Motor . 6 (4) Prepared and wired by the user. . 7 (5) Software installation . 7 2. 2 Controller settings . 8 (1) Start the setup software . 8 (2) Basic Parameter Setup . 9 (3) Step data setting . 9 3Start up procedureTest operation using a computer

Set t i ng at t he t i m e of shi pm ent i s 01. 6 4 6 4 5 5 Set t i ng t he t erm i nat or Set PRO FI BU S com m uni cat i on l i ne t erm i nat or.

VQZ Model Weight Weight (g) VFN200N/Flow Characteristics VZ Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) VFN212N-5D-02F 240 380 VS C 2.68 2.68 b 0.40 0.40 Cv 0.72 0.72 C 5.41 5.41 b 0.31 0.31 Cv 1.38 1.38 VFN212N-5D-02F-D 2 position Single solenoid VFN Double solenoid How to Order VFN212 5 D N 02 F Z NAMUR Interface Solenoid Voltage Nil D Single solenoid Double solenoid Thread

Contents Bore size (mm) CY3R6-PS 6 CY3R6-PS Set of left nos. @4, @6, @7, @8 @4 @5 @6 @7 @8 @9 #0 Cylinder tube gasket NBR Set of left nos. @4, @6, @7, @8, @9, #0 Wear ring A 6, 10: Not available Special resin CY3R10-PS 10 CY3R10-PS Wear ring B Special resin CY3R15-PS 15 20 25 32 40 50 63 CY3R15-PS CY3R20-PS CY3R25-PS CY3R32-PS CY3R40-PS CY3R50-PS CY3R63-PS Wear ring C Special resin CY3R20

Example: In case of 6 stations of air suction filter ZFA (single) ZFA100-01 6 pcs. (Brackets for 6 stations) ZZFA1-06 1 pc. ZFA200 Both left and right brackets.

Contents Bore size (mm) REAH20-PS REAH25-PS REAH20-PS REAH25-PS 20 25 Set of left nos. #0, #1, #2, #3, #4, #5, #6 #0 #1 #2 #3 #4 #5 #6 Wear ring A Special resin Wear ring B Special resin Note) Seal kit includes #0 to #6. Order the seal kit, based on each bore size. Note) It may be difficult to replace the cushion seal #6. Seal kit includes a grease pack (10 g).

B 8370: JIS B 8361: JIS B 9960-1: 1 JIS B 8433-1993: *2) 1.. 2. 3. 1. 2. 3. 4. 2 VT301-0MP0001 / / / / 1 1 1 1 1 1 1 1.5 .5 .5 .5 *3) *3) *3) *3) 1 1 1 1 1 1 1 1 () 3 VT301-0MP0001 VTA301 VTA301 VTA301 VTA301 3 3 3 3 / / / / / / / / -10 1 Nm Rc1/8 79 Rc1/4 1214 1224 1/8 1 21 ISO VG32 MSDS 2 ISO VG32 4 VT301-OMP0001 VTA301 VTA301 VTA301 VTA301 3 3 3 3 / / / / 30 1 1 ISO VG32 2 ISO

CAT.ES100-42 B 2-Color Display Type High-Precision Digital Pressure Switch Series ZSE30/ISE30 Improved, easy-to-read 2-color display 2-Color Display Type High-Precision Digital Pressure Switch Series ZSE30/ISE30 Series ZSE30/ISE30 2-color digital display allows you to choose the setting according to your application requirements. 4 different display settings are available.

T IDK Cover Cover installation latch 249 DMK Series Dimensions DMK6 36 0.1 36 0.1 44 37 (Socket side: With a cover) Panel mounting hole Panel mounting hole 4 x 4.3 M4 round head screw 40.5 59.5 SMC 6 1 19 26 36 2 5 3 4 11 36 45 38 DMK12 43 0.1 43 0.1 47 53 Panel mounting hole (Socket side: With a cover) Panel mounting hole 4 x 4.3 M4 round head screw 50.5 69.5 SMC 6 1 8 2 3 9 10 46 25

BLEED 2 x 1/8 Pressure gauge port 141 43 91.7 76.1 65.3 22 48.1 EXH OUT IN 2 x 1/4 to 1/2 Port size 2 x 1/2 Port size 66 With digital pressure switch: IR30l1 2-0llEl-A 76 48 72.5 53 16 M12 x 1 Mounting hole 2.3 M28 x 1.5 BLEED 30 141 91.7 76.1 65.3 22 48.1 2 x 1/8 Pressure gauge port EXH OUT IN 66 2 x 1/2 Port size 2 x 1/4 to 1/2 Port size 804 IR1000-A/2000-A/3000-A Series Specific Product

PF-OMK0003CN-E () * ,UL UL1310 2 UL15852 30[Vrms] (42.4[V ])(2 ) UL JIS B 8392-1 1.1.21.6.2 -5No. PF-OMK0003CN-E * (1 /) FG 49N ) 1 () -6No. PF-OMK0003CN-E *() 6 33 2 () () 10m DC(-)() () -7No. PF-OMK0003CN-E * ( ) () CE 050 -8No. PF-OMK0003CN-E * 523 * -9No. PF-OMK0003CN-E (11 ) -10No.

JFA connector J4000 series SC02B-J42SK-GHXR 2 24 VDC (1000) 1 RS-485 BUS + 2 RS-232C RD 1 2 3 4 5 3 RS-232C SD 4 RUN/STOP signal input Alarm, RUN/STOP , Communication connector 5 SG 6 Output cutoff alarm (open when alarm occurs) 9 8 7 6 7 Common for output cutoff alarm D-sub 9 pin (socket type) Holding screw: M2.6 8 RUN/STOP signal input 9 RS-485 BUS 8 HEF Series Operation Display Panel

VR VH VHS Construction VHS20/30 VHS40/40-06/50 6 8 7 2 2 5 5 1 4 IN OUT OUT IN 1 9 3 EXH. EXH. Component Parts No.

6 t Zinc chromated w Electroless nickel plated Black zinc chromated Accessory Accessory IN 2 Series ARJ310 Dimensions ARJ310-01 ARJ310F-01 Approx. 31 Approx. 56 Approx. 56 Approx. 35 32 22 M12 x 1 Panel fitting dimensions 12.5/Panel thickness: 4 or less Approx. 27 19 2 2 -5.5 Approx. 57.2 8.5 Approx. 82.5 15 Applicable tube O.D. 4, 6, 5/32, 1/4 Port size Rc, NPT 1/8 2 2 1 1 Pressure gauge