Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator Both Sides Shaft Outputs, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 100,
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 100, Valves: Provided
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 100, Valves
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 100, Valves
Oscillation Angle A: 190°, Torque (Range)(N⋅m): 10 to Less than 20 / 20 to Less than 50 / 50 to Less than 100 / 100 or More, Type: Rotary Actuator Both Sides Shaft Outputs, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Tube Nominal Diameter: 100, Valves:
Bore sizes: 6, 10, 15, 20, 25, 32, 40, 50, 63; Stroke lengths: 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1500, 3000, 5000 mm; Minimum operating pressure: 0.12 ~0.16 MPa (17 ~ 23 psi); Speed: 50 ~ 500 mm/sec.; Fluorine grease; ISO Class 5 (Class 100)
Bore sizes: 6, 10, 15, 20, 25, 32, 40, 50, 63 mm; Stroke lengths: 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1300 mm; Direct mount type; Speed: 50 ~ 400 mm/sec.; Fluorine grease; ISO Class 5 (Class 100); Auto switch capable
.cat-top-box{display: inline-flex;} .cat-image-holder{ width: 40%; } .cat-image-holder img{ width: 100%; } .cat-description-holder{ width: 50%; } table.specifications-table { border: 2px solid #B6B6B6; width: 100%; margin:30px 0; } .specifications-table td { padding: 8px 4px; margin: 3px; border: 1px solid #b6b6b6; text-align: center; } .specifications-table
.cat-top-box{display: inline-flex;} .cat-image-holder{ width: 40%; } .cat-image-holder img{ width: 100%; } .cat-description-holder{ width: 50%; } table.specifications-table { border: 2px solid #B6B6B6; width: 100%; margin:30px 0; } .specifications-table td { padding: 8px 4px; margin: 3px; border: 1px solid #b6b6b6; text-align: center; } .specifications-table
.cat-top-box{display: inline-flex;} .cat-image-holder{ width: 40%; } .cat-image-holder img{ width: 100%; } .cat-description-holder{ width: 50%; } table.specifications-table { border: 2px solid #B6B6B6; width: 100%; margin:30px 0; } .specifications-table td { padding: 8px 4px; margin: 3px; border: 1px solid #b6b6b6; text-align: center; } .specifications-table
Refer to back page 50 for Safety Instructions, pages 543 to 546 for Flow Control Equipment Precautions, and pages 599 to 601 for Specific Product Precautions.
Specications [mm] Table 1 Cylinder Strokes Bore size Stroke 16 15, 20, 25, 30 20, 25 15, 20, 25, 30, 35, 40, 45, 50 32 to 63 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Ambient and uid temperature range 32 to 302F [0 to 150C] Seal material Fluororubber Grease Heat resistant grease Standard stroke See Table 1. Dimensions See below.
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC
Please contact us for the latest version.sales@ocaire.com, ZSE40/50/60 1/4 PORTED, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, KC, ZSE40/50/60 1/4 PORTED, 0.35638 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog outputAuto-shift inputDisplayDisplay
Please contact us for the latest version.sales@ocaire.com, ISE40/50/60 1/4 NPT VERSION, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, DB, ISE40/50/60 1/4 NPT VERSION, 0.19841 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureWetted parts materialApplicable fluidPort sizePower supply voltageCurrent consumption--Switch outputRepeatabilityHysteresisAnalog outputAuto-shift
Standard stroke 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate strokes are available in 1 mm increments without stroke adjustment with a spacer.
Ambient temperature 50-140'F (10.60'C) . Proiection structure lEC529 spec.lP67, waierproot (JlSC0920), oilproof . Sutfix L for the model with a 3lhlong lead wire. (Exampl6) D-A731 Solid. State Sutitch Specifieatians I Ro;il Mounted.
IDFA4E15E1 L N PE M3 6.5mm 1.25mm 2 1-1 IDFA Series 1 4 IDX-OM-W017 2 2 , 2 1 IDFA4E15E 20kg 2 2 2 2 2 1 2000m 240 050 600mm 600mm 600mm ( 600mm ) 600mm 2-1 IDFA Series 2 1 IDX-OM-W017 2 2 2 2 6 6-2 IDFA4E15E 2 2 3 50 50 2 2 4 10mm 2-2-2 IDFA Series 2 2 IDX-OM-W017 2 ( 2 2 5 6-1 IEC AC230V 30mA 5A 216AWG,3 ,812 1.25 0.1m 30m M3 1.25-3 6.5mm ()M3 0.61Nm
No.PS-OMU0008CN-D // ZSE20C(F) ISE20C(H) 2 9 11 12 16 16 19 21 [] 24 25 3 26 28 30 30 30 F0 32 F1 OUT1 33 F2 OUT2 36 F3 38 F4 39 F5 FUNC 41 F6 43 F10 44 F11 50 F80 51 F81 52 F82 54 F90 55 F96 57 F97 58 F98 60 F99 62 63 67 67 68 77 77 79 -1No.PS-OMU0008CN-D 1 (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC