SY NO SIZE RATING. .14283 lb. 2D.
VFR5000 NO SIZE RATING. 1.95475 lb. 2D.
SY7000 NO SIZE RATING. 1.40447 lb. 2D.
VQ1000 NO SIZE RATING. .17636 lb. 2D.
VQ4000 NO SIZE RATING. 0.50028 lb. 2D.
SY NO SIZE RATING. .12259 lb. 2D.
SY NO SIZE RATING. .13271 lb. 2D.
SV2000 NO SIZE RATING. .44092 lb. 2D.
SY7000 NO SIZE RATING. 0.67229 lb. 2D.
The straight piping length shall be 5 times (5D) or more of the piping size to achieve the stable measurement. 3 Accuracy change [% F.S.] 2 [mm] 1 Model Straight piping length D 5D LFE1 11 55 LFE2 21 105 LFE3 27 135 [Port size] [Measurement conditions] Fluid: Tap water Pressure: 0.2 MPa 0 D 2D 3D 4D 5D LFE1: 3/8 inch LFE2: 3/4 inch LFE3: 1 inch 0 Straight piping length Operating Pressure
(d = Screw O.D.) 2d or more Caution 1. Use cylinders within the piston speed range. An orifice is set for this cylinder, but the piston speed may exceed the operating range if the speed controller is not used. If the cylinder is used outside the operating speed range, it may cause damage to the cylinder and shorten the service life.
Bottom of cylinder For bottom mounting, make a hole to the mounting base of the customer for hexagon socket head cap screws. 2d or more (d = Screw O.D.) Caution 1. Use cylinders within the piston speed range. An orifice is set for this cylinder, but the piston speed may exceed the operating range if the speed controller is not used.
Test range Thermometer Test equipment Pressure tap Pressure tap Throttle valve on the Flow meter Throttle valve on the downstream side 2d 6d upstream side 20d 7d Fig. (3) Test circuit based on IEC 60534-2-3, JIS B 2005-2-3 100 100 Saturated steam flow rate Q0 [kg/h] (when Kv = 1) Upstream pressure Water flow rate Q0 [L/min] (When Kv = 1) 50 40 40 50 P1 = 1 MPa P1 = 0.8 MPa P1 = 0.6 MPa
Sealant tape Tube deformation ratio at the minimum bending radius = L D 2d 1 x 100 Here, : Deformation ratio [%] d : Tubing diameter [mm] L : Measured length [mm] D : Mandrel diameter [mm] (Twice against the minimum bending radius) Test temperature: 20 5C Relative humidity: 65 5% Mandrel 3. Do not use fluids other than listed on the specifications.
Note 3) Surface treatment No. 2D applies to the external surface of the vessel. (Scratches, scrapes, blotches and uneven color may be present as long as they do not interfere with function or performance.) The symbol refers to surface finishing of JIS G 4305 cold rolled stainless steel sheet.
NEW SY5000 NO SIZE RATING. 0.25768 lb. 2D.
ARM NO SIZE RASTANDARD (NPT). 0.55115 lb. 2D.
SY7000 NO SIZE RATING. 0.60813 lb. 2D.