Magnet: None, Mounting: E (Front screw clearance hole), Overall Length: Standard, Bore Size: 250 (2 1/2"), Stroke: 200 (2"), Body Option: C (Rubber Bumper)
Magnet: None, Mounting: E (Front screw clearance hole), Overall Length: Standard, Bore Size: 250 (2 1/2"), Stroke: 200 (2"), Body Option: C (Rubber Bumper), Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m)
Magnet: None, Mounting: E (Front screw clearance hole), Overall Length: Standard, Bore Size: 250 (2 1/2"), Stroke: 400 (4")
Magnet: None, Mounting: E (Front screw clearance hole), Overall Length: Standard, Bore Size: 400 (4"), Stroke: 250 (2 1/2")
10%, 12 to 15 VDCPower supply voltage 24 VDC type: 0.12 A or less Power supply voltage 12 to 15 VDC type: 0.18 A or less0 to 5 VDC, 0 to 10 VDC4 to 20 mA DC, 0 to 20 mA DCApproximately 10 k Approximately 250 1 to 5 VDC (Load impedance: 1 k or more) Output accuracy: Within ?6% (Full span)Within ?1% (Full span)Within 0.5% (Full span)Within ?0.5% (Full span)Within 0.2% (Full span)Within ?
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 14 (1 1/2), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 14 (1 1/2), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 14 (1 1/2), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: A (Calibration
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 12 (1 1/4), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
10%, 12 to 15 VDCPower supply voltage 24 VDC type: 0.12 A or less Power supply voltage 12 to 15 VDC type: 0.18 A or less0 to 5 VDC, 0 to 10 VDC4 to 20 mA DC, 0 to 20 mA DCApproximately 10 k Approximately 250 1 to 5 VDC (Load impedance: 1 k or more) Output accuracy: Within ?6% (Full span)Within ?1% (Full span)Within 0.5% (Full span)Within ?0.5% (Full span)Within 0.2% (Full span)Within ?
Maximum Load Weight (g) Weight (g) Cylinder stroke (mm) 5 Maximum load weight Model Model 10 15 20 25 30 MXU6 MXU10 MXU16 MXU6 MXU10 MXU16 100 66 72 81 88 97 103 200 115 124 138 147 166 174 400 216 215 251 250 285 300 8-3-3 4 Series MXU Allowable Moment Precautions Allowable moment (Nm) Correction value of moment center position distance (mm) Model Stroke Be sure to read before handling.
type) Min. bending radius Note 1) (mm) 8 15 15 22 29 Operating temperature 20 to +60C Material Polyurethane Tube drawing strength (N) (Using One-touch fitting) KK130 DM One-touch fitting Model Model Applicable tubing model Length TJ-0425 TUS0425 18 TJ-0604 TUS0604 19 TJ-0805 TUS0805 20.5 TJ-1065 TUS1065 23 TJ-1208 TUS1208 24 KDM Without inner sleeve 15 60 60 85 110 With inner sleeve 80 230 250
10%, 12 to 15 VDCPower supply voltage 24 VDC type: 0.12 A or less Power supply voltage 12 to 15 VDC type: 0.18 A or less0 to 5 VDC, 0 to 10 VDC4 to 20 mA DC, 0 to 20 mA DCApproximately 10 k Approximately 250 1 to 5 VDC (Load impedance: 1 k or more) Output accuracy: Within ?6% (Full span)Within ?1% (Full span)Within 0.5% (Full span)Within ?0.5% (Full span)Within 0.2% (Full span)Within ?
10%, 12 to 15 VDCPower supply voltage 24 VDC type: 0.12 A or less Power supply voltage 12 to 15 VDC type: 0.18 A or less0 to 5 VDC, 0 to 10 VDC4 to 20 mA DC, 0 to 20 mA DCApproximately 10 k Approximately 250 1 to 5 VDC (Load impedance: 1 k or more) Output accuracy: Within ?6% (Full span)Within ?1% (Full span)Within 0.5% (Full span)Within ?0.5% (Full span)Within 0.2% (Full span)Within ?
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 14 (1 1/2), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 14 (1 1/2), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None, Calibration Certificate: A (Calibration
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 14 (1 1/2), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 14 (1 1/2), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 14 (1 1/2), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 14 (1 1/2), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None, Calibration Certificate: A (Calibration