A 67 G1/2 [3(R) port] (25.5) Type E 66.9 LOCK PUSH 5
Attach the ionizer body and brackets with M5 screws. (5) Adjust the angle of the ionizer body to make the static neutralization effective, and fix with the rotating set screws (M5) of each bracket. (6) Make sure to ground with the ground resistance of 100 ohms or less by connecting DC1(-) lead wire [blue] M5 M5 screws of the power supply cable.
The connection M5 thread. Tighten thread to recommended torque value. 3. After installation, check internal leakage (leakage across seat) with inert gases. Perform a helium leak test depending on applications. Maintenance Warning 1.
Relief port M5 thread The body material has been changed to aluminum. ITVH X234 SRH Standard model no.
(M5) 01T r/ NPTF {A port onl ' Special order Notel) Indicale in parentheses al end of parl # Ex.
x 0.8 Weight (kg) 0.5 Dimensions 40 Not available to mount 40 Holding screw for main air supply (M2.5) 16 Main air suppy flow adjustment screw Initial air supply flow adjustment nut 11 Holding screw for initial air supply (M5) 82.5 9 MODEL M port M5 x 0.8 PRESS. 0.2MPa~10Pa 0.4~0.7MPa OPERATING PRESS IN Main air supply valve port TEMP. 5~60C S port M5 x 0.8 Initial air supply valve port
C E E (KF flange) Fd (K flange) Fn D H B A G A Unit: mm Model A B C D E Fn Fd G H XLA-16-2 40 108 38 20 30 17 44 XLA-25-2 50 121 48 27 12 40 26 44 XLA-40-2 65 171 66 39 11 55 41 67 XLA-50-2 70 185 79 46 11 75 52 72 XLA-63-2 88 212 100 55 11 87 95 70 76 XLA-80-2 90 257 117 65 11 114 110 83 104 12 XL-OMS0001-B 6.
Heat exchanger Ventilation Circulating fluid Expansion E circuit valve A Expansion Inverter pump valve B Pump E Temp. sensor (Ref. discharge Ball tap Fluid level gauge TS Press. sensor Over flow port (Ref. low press.)
Please refer below for calculation of kinetic energy. 2 I 2 1 E E : Kinetic energy J I: Inertia moment kg/m2 : Angular speed rad/s Allowable kinetic energy for the rotary actuator is limited. The limit of rotation time is obtained by calculating inertia moment. Please refer following for obtaining inertia moment.
Check the product for the following points before operation. a) Damage to power supply line and signal line. b) Looseness of the connector to each power line and signal line. c) Looseness of the actuator /cylinder and controller /driver mounting. d) Abnormal operation. e) Emergency stop of the total system. 3.
Allowable kinetic energy (J) t Model Allowable kinetic energy (mJ) : Rotation angle [ rad ] : Rotation time [ s ] Basic type CRJB05 0.25 Kinetic energy E is obtained by: With external stopper CRJU05 1.0 Basic type CRJB1 0.40 Basic type CRJU1 2.0 E Therefore, the rotary table rotation time is: E: Allowable kinetic energy [ J ] : Rotation range [ rad ] I: Moment of inertia [ kgm2 ] During
Description Material Note 1 Body Aluminum alloy Anodized 2 Branch passage PPS 3 Gasket HNBR 4 Sensor base PPS 5 Gasket HNBR 6 Sensor Au, Pt, Al2O3 Dimensions A B 70 H F E D 1.5 OUT IN 4 x P L K 2 x Port size N Symbol Model Port size A B D E F H K L N P PF3A703H Rc1, NPT1, G1 130 45 79.1 55.3 22.5 25 35 60 30 M4 x 0.7 depth 7 PF3A706H Rc1 1/2, NPT1 1/2, G1 1/2 170 60 94.1 70.3 30 68 45
Weights Unit: g (oz) End boss type (symbol) Model H E M K MHZA2-6 28 (0.99) 28 (0.99) 28 (0.99) 28 (0.99) MHZAJ2-6 29 (1.02) 29 (1.02) 29 (1.02) 29 (1.02) 9
This lowers the pressure in the diaphragm chamber q and the force generated by the pressure regulator spring e pushes down the diaphragm.
Applicable manifold base Plug-in type With attachment plug lead wire: Type 51G Description Component parts Manifold block u, Junction box i, Lead wire assembly o Tie-rod y, O-ring e, r, Seal A q VVZS2000-1A-1-Port size (1) Manifold block assembly Manifold block u, Tie-rod y, O ring e, r, Seal A q Non plug-in type: Type 51 VVZS2000-1A-2-Port size (1) Plug-in type With D-sub connector: Type
Applicable manifold base Plug-in type With attachment plug lead wire: Type 51G Description Component parts Manifold block u, Junction box i, Lead wire assembly o Tie-rod y, O-ring e, r, Seal A q VVZS3000-4-1-Port size (1) Manifold block assembly Manifold block u, Tie-rod y, O-ring e, r, Seal A q Non plug-in base type: Type 51 VVZS3000-1A-2-Port size (1) Manifold block u, Junction box i, Lead
When error occurs Precautions W hen an e rror occurs,take the following steps. The tenSile strength of the cord is 49N (Skgf). Con t e nl~s___ __-+;;-:::-:::-:-~D~;S~~S~~ o ~n,-:-:cc_ ; I i Tensile strength greater than that will cause Set data is changed by some Influence Push the RESET key to set troubte.
Controller model Mounting screw Mounting bracket assembly LC1-1H-N3 M3 x 0.5 LC1-1-N3 Power terminal: TB LC1-1H-N5 M5 x 0.8 LC1-1-N5 LC1-1H-L3 M3 LC1-1-L3 LC1-1H-L5 M5 LC1-1-L5 Communication connector: CN3 Motor power line connector: CN5 Mounting with T-nuts Regenerative absorption unit connector: CN6 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main
Tubing length = (2E + X) E dimension E dimension X 1% of E-dimensions (as a guide). E-dimensions vary according to the fitting size. Please refer to the WEB catalog or the Best Pneumatics No. 7 for details. 2. Insufficient tubing length or use of the tubing under tensile stress may cause leakage or breakage of the fitting.