SMC Corporation of America
Elite Part Number Search
Search Results "JXCL18-LEKFS40REB-200"

) Discharge pressure (MPa) Discharge pressure (MPa) SUP = 0.5MPa 0.4 0.4 0.3 SUP = 0.5MPa SUP = 0.5MPa 0.4MPa 0.3 0.3 0.4MPa 0.4MPa 0.2 0.3MPa 0.2 0.2 0.3MPa 0.3MPa 0.1 0.1 0.1 0.2MPa 0.2MPa 0.2MPa 00 5 10 15 00 5 10 15 00 5 10 15 Flow rate (l/min) Flow rate (l/min) Flow rate (l/min) PAP3313-T13: Flow rate characteristics (10Hz)* PAP3313-T13: Air consumption PAP3310-T13: Air consumption 200

lines, the pilot air pressure for this point is approximately 0.25MPa. 40 20 1 0 2 3 4 5 6 7 Cycle (Hz) PA513 Air consumption 400 350 Air consumption l/min (ANR) SUP=0.5MPa Note 1) Even when switching cycles are changed for PA3000 with SUP=0.2MPa or PA5000 with SUP=0.2MPa or 0.3MPa, there is almost no change in the lifting height. 300 250 SUP=0.3MPa Calculating air consumption (for PA3000) 200

osi Within 1% for each 1.5 DSi Within 0.5% for each 1.5 psi Within 0.3% for each 1.5 psi Within 0.5% for each 7.5 osi *Fof 1/2 split range add 1.5% to these values Use clean, dry, oil free air Recommended for air preparation: NAC 2030"N02 or NAC 2040-N02 filter, coalescer, regulator combination Rel. catalog N5-Gl l\,lodular type FFL Combinalion Recommended for control of pilot signal: NIT 200

Repetition Supply pressure: 1.0MPa Set pressure: 0.45MPa Pressure characteristics Flow characteristics 1000 1 900kPa 900 800kPa 800 Output deviation factor % F.S. 0.5 700kPa 700 Set pressure kPa 600kPa 600 Out 500kPa 500 0 400kPa 400 Return 300kPa 300 -0.5 200kPa 200 100kPa 100 50kPa 0.4 0.6 0.8 1.0 -1 0 1 2 3 4 5 6 0 7 1.2 Flow rate l/min (ANR) Supply pressure MPa Series ITV009 Repeatability

SA Y59B MF 200 32 Straight Type Number of auto switches 3-dimensional transfer single unit Bore size 2pcs. 1pc. "n" pcs. Nil S n Auto switch type 15 32 15mm 32mm Nil Without auto switch Refer to the table below for auto switch part numbers. Straight type Stroke Air supply unit Note 1) 200 250 300 350 400 450 500 600 1000 200mm 250mm 300mm 350mm 400mm 450mm 500mm 600mm 1000mm Qty.

Auto switch capable Pressure control Simple motion controlextension and retraction Extended end Retracted end Thrust: Up to 196N Stroke: 25 to 200 mm Speed: Up to 200 mm/s Series LZB Series LZC Series LZ/LC3F Suitable for an environment where an air supply is not available. Suitable for an environment where an air supply is not available.

VQC1100 10ms2ms: 200 million cycles VQC2100 20ms2ms: 200 million cycles VQC4100 17ms3ms: 100 million cycles SV VQC Refer to catalog for details.

P(SUP) port For top ports 4 4 4 4 4 4 4 4 R 3 2 2 2 2 2 2 2 2 P 1 13 29.5 26 2n-C3, C4, C6 A, B port 43.5 58 P = 11.5 Dimensions Formulae L1 = 11.5n + 55.5 L2 = 11.5n + 73 n: Stations (max. 16 stations) L n 1 67 84.5 112.5 123 2 78.5 96 125 135.5 3 90 107.5 137.5 148 4 101.5 119 150 160.5 5 113 130.5 150 160.5 6 124.5 142 162.5 173 7 136 153.5 175 185.5 8 147.5 165 187.5 198 9 159 176.5 200

Important 40% A manufacturer of automobile parts Example reduction Electricity: 10,000 kW 6,000 kW Cost: Reduction of 200 million yen/year Financial loss due to air leakage Hole diameter mm Leakage per year m3/year (ANR) Annual financial loss yen/year 12 50 200 449 799 1,248 Air leakage l/min (ANR) 0.5 1 2 3 4 5 6k 22k 90k 202k 359k 561k 1.910 3 7.510 3 29.910 3 67.410 3 12010 3 18710 3 Unit

Metric size Type (recommended flow rate) Symbol Tubing size Applicable model 04 ZFC100 ZFC100 ZFC200 ZFC200 4 Flow rate l/min (ANR) (SCFM) Symbol Tubing size 100 200 101 201 Max. 20 (0.70) Max. 50 (1.75) Max. 20 (0.70) Max. 50 (1.75) Metric size (release button: light gray) 06 6 08 8 Inch size (release button: orange) Inch size Symbol 03 Applicable model ZFC101 ZFC101 ZFC201 ZFC201 Tubing

Multistage Ejector Series ZL112/212 Energy saving, large flow rate, 3 stage diffuser construction Series ZL112/212 Suction flow rate increased 250% and air consumption reduced 20% with 3 stage diffuser construction (Versus 1.3, one stage model) 1 stage performance Maximum suction flow rate l/min (ANR) Air consumption l/min (ANR) Vacuum pressure Q1 Q2 Q3 ZL112 100 200 ZL212 63 126 Q1 Q2 Q3

40 X X Silicon rubber X X X X 0 to 60 60 X Urethane rubber X 0 to 250 60 Fluoro rubber X X 0 to 100 50 X X Conductive NBR Conductive silicon rubber 10 to 200 50 X X X X X The characteristics shown above represent the general properties of the rubber materials.

This wiring is common in each mode. (1) Using 3-phase 200 V AC to 240 V AC power supply for LECSN2-T Note 1. Between P3 and P4 is connected by default. 2. Always connect between P+ and D terminals. (Factory-wired) 4.

Power supply is AC200V single phase (Note 4) Controller Forced Alarm forced stop stop ON OFF RA1 RA2 MC MC SK Driver Servo amplifier Servo motor NFB MC CNP1 L1 1-phase 200 to 230VAC CNP3 (Note 6) U 2 L2 U Motor [1] V 3 L3 V M N W 4 W 1 P1 (Note 1) P2 PE CNP2 P (Note 2) C [3] [2] D (Note 3) Encoder CN2 Encoder cable L11 L21 CN3 CN3 24VDC Forced stop EM1 DOCOM (Note 5) DOCOM DICOM (Note 5)

Power supply is AC200V single phase (Note 4) Malfunction RA1 OFF ON MC MC SK EMG stop switch Driver Servo amplifier Servo motor MC (Note 7) MCCB CNP1 1-phase 200 V AC to 240 V AC (Note 11) L1 CNP3 (Note 6) U U L2 Motor V V L3 M [1] W NW P3 (Note 1) (Note 10) P4 CNP2 P+ [2] (Note 2) C [3] D (Note 11) (Note 3) Encoder CN2 Encoder L11 cable L21 (Note 8) Main circuit power supply CN3 EM2 24 V

Setup software (SigmaWin+) is necessary for the setting of the parameter. 1 Please download setup software via our website. 2 Prepare USB cable (LEC-JZ-CVUSB) separately. 4.1 power supply specifications When using the DRIVER with single-phase, 200 V power input, set parameter Pn00B.2 to 1.

Setup software (SigmaWin+) is necessary for the setting of the parameter. 1 Please download setup software via our website. 2 Prepare USB cable (LEC-JZ-CVUSB) separately. 4.1 power supply specifications When using the DRIVER with single-phase, 200 V power input, set parameter Pn00B.2 to 1.

(50/60Hz) AC230V (50Hz) PRS AC200/200,220 (50/60Hz) OLR C01 2 2 1 L C11 N TB PRS PE PC TB P FM C11 200V C11200V IDU6E-10 IDU6E-20/23 ILS ILS PTC AC200/200 (50/60Hz) AC230V (50Hz) PTC AC200/200,220 (50/60Hz) AC100/100,110 (50/60Hz) C01 L CM CM PC N OLR OLR PE TB PRS PRS FM P P FM C11 6-5 6 2 IDU Series 6-4 6 4 IDX-OM-W014 7 C 7 C 7-1 7-2 1) 2) IDU Series 7-1 71 IDX-OM-W014

Drain piping is long, or I.D. of Tube I.D. should be 6.5 (1/4 the piping is small. inch) or more and its length should (Back pressure is applied.) be within 5m (200 inch). Riser pipework should be avoided. Drain exhaust and bowl seat Replace the auto drain. were broken.