Electronic gear ratio setting range: 0.001 Electronic gear ratio (B/A) 4000 If the electronic gear ratio is outside this range, a parameter setting error 1 (A.040) will be output. 25 - 4.4.1 List of the electronic gear setting for each actuator The recommended the electronic gear for each actuator. Please change the electronic gear by use of the customer.
Electronic gear ratio setting range: 0.001 Electronic gear ratio (B/A) 4000 If the electronic gear ratio is outside this range, a parameter setting error 1 (A.040) will be output. 24 - 4.4.1 List of the electronic gear setting for each actuator The recommended the electronic gear for each actuator. Please change the electronic gear by use of the customer.
Pr = a (PD) + b (PD) = (Pr b) / a Pr PD a b [] a b MPa 0.00025 -0.25 kPa 0.25 -250 kgf/cm 2 0.002549 -2.549 ISE70 bar 0.0025 -2.5 psi 0.03626 -36.26 MPa 0.0004 -0.4 kPa 0.4 -400 kgf/cm 2 0.004079 -4.079 ISE71 bar 0.004 -4 psi 0.05802 -58.02 [] (ISE70 MPaPD=2000 ) Pr = a (PD) + b = 0.00025 2000 0.25 = 0.25[MPa] (ISE70 MPaPr=0.75[MPa]) (PD) = (Pr b) / a = [0.75 (-0.25)]/0.00025 = 4000
0.00125 -1.25 kgf/cm 2 0.0127475 -12.7475 ISE76G bar 0.0125 -12.5 psi 0.1813 -181.3 MPa 0.0025 -2.5 kgf/cm 2 0.0254925 -25.4925 ISE77G bar 0.025 -25 psi 0.3626 -362.6 MPa 0.004 -4 kgf/cm 2 0.0407875 -40.7875 ISE78G bar 0.04 -40 psi 0.58015 -580.15 [] (ISE70GMPaPD=2000 ) Pr = a (PD) + b = 0.00025 2000 0.25 = 0.25[MPa] (ISE70GMPaPr=0.75[MPa]) (PD) = (Pr b) / a = [0.75 (-0.25)]/0.00025 = 4000
This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000, S0700 and the new SY series valves.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Dedicated output serial wiring, Tie rod base, 4000 series, Series EX120, Number of outputs: 16, Maximum number of stations: 16 (over 8 requires manifold spec. form), SS5V 08 Station Manifold, Tie-Rod Base, 4/5 PORT SOLENOID VALVE, VVM, 1.12 lb
MHS, Parrallel Style Air Gripper, GRIPPER, C40, 4000 lb
EX260 compact serial interface unit is applicable to the SY3000/5000, SV1000/2000/3000, VQC1000/2000/4000 and S0700 series valves. The EX260 module is an output only SI unit that can be connected to any manifold designed for the EX250 series. Available protocols are PROFIBUS DP, DeviceNet and EtherCAT., SI UNIT, VALVE, EX300 SERIAL INTERFACE UNIT, 22, EX300, .44092 lb
Model: 4000, Output Pressure: 0.7MPa, Terminals: DIN Connector, Thread: NPT, Input Signal: 4~20mA, Port Size: 2 [1/4" (2000,4000)], Accessory: Bracket, Pressure Gauge: -
Model: 4000, Output Pressure: 0.5MPa, Terminals: DIN Connector, Thread: NPT, Input Signal: 0~10VDC, Port Size: 3 [3/8" (2000,4000)], Accessory: Bracket, Pressure Gauge: Indication of k and psi
Model: 4000, Output Pressure: 0.5MPa, Terminals: DIN Connector, Thread: Rc(PT), Input Signal: 0~10VDC, Port Size: 3 [3/8" (2000,4000)], Accessory: Bracket, Pressure Gauge: Indication of k and psi
Model: 4000, Output Pressure: 0.7MPa, Terminals: DIN Connector, Thread: NPT, Input Signal: 0~5VDC, Port Size: 2 [1/4" (2000,4000)], Accessory: Bracket, Pressure Gauge: Indication of psi and k
Model: 4000, Output Pressure: 0.7MPa, Terminals: DIN Connector, Thread: NPT, Input Signal: 0~10VDC, Port Size: 3 [3/8" (2000,4000)], Accessory: Bracket, Pressure Gauge: Indication of psi and k
Model: 4000, Output Pressure: 0.35MPa, Terminals: Conduit, Thread: NPT, Input Signal: 4~20mA, Port Size: 2 [1/4" (2000,4000)], Accessory: Bracket, Pressure Gauge: -
Model: 4000, Output Pressure: 0.35MPa, Terminals: DIN Connector, Thread: NPT, Input Signal: 0~10VDC, Port Size: 2 [1/4" (2000,4000)], Accessory: -, Pressure Gauge: -
Model: 4000, Output Pressure: 0.5MPa, Terminals: DIN Connector, Thread: Rc(PT), Input Signal: 0~10VDC, Port Size: 3 [3/8" (2000,4000)], Accessory: -, Pressure Gauge: -
Model: 4000, Output Pressure: 0.9MPa, Terminals: DIN Connector, Thread: NPT, Input Signal: 0~10VDC, Port Size: 3 [3/8" (2000,4000)], Accessory: -, Pressure Gauge: -
Model: 4000, Output Pressure: 0.1MPa, Terminals: DIN Connector, Thread: NPT, Input Signal: 0~10VDC, Port Size: 3 [3/8" (2000,4000)], Accessory: Bracket, Pressure Gauge: Indication of psi and k
Model: 4000, Output Pressure: 0.1MPa, Terminals: Conduit, Thread: NPT, Input Signal: 4~20mA, Port Size: 3 [3/8" (2000,4000)], Accessory: -, Pressure Gauge: -
Model: 4000, Output Pressure: 0.1MPa, Terminals: Conduit, Thread: NPT, Input Signal: 0~10VDC, Port Size: 3 [3/8" (2000,4000)], Accessory: -, Pressure Gauge: -