Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket: R
Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 04 (0.5~4L/min), Return Unit: W (Flow Adjustment Valve + Stop Valve), Thread: Rc, Port Size: 03 (3/8), Flow Switch Output: AT (Integrated Display; Out 1: NPN; Out 2: (NPN) ⇔ NPN ; Temperature Sensor: Yes), Lead Wire: with Lead Wire with M8 Connector (3m), Flow Switch Unit: M (Integrated Display, IO-Link Campatible; Instantaneous
The VXZ series is a 2 port, pilot operated solenoid valve capable of operating at higher differential pressures by maintaining a zero differential pressure on the seat.
ModelMin. operating pressure differential (MPa)Max. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Weight (g) ACDCCbCv1/2 (15A)15VXZ2240-04--1.00.723.00.346.01.5760
Optimization of cushion timing and intensity reduces impact at the stroke end without the need to add and install shock absorber. Example application is to reduce impact when opening/closing machine door.
Optimization of cushion timing and intensity reduces impact at the stroke end without the need to add and install shock absorber. Example application is to reduce impact when opening/closing machine door.
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket: None,
Valve; Stop Valve: None), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: Flow Adj.
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: AT (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L;
The VXZ series is a 2 port, pilot operated solenoid valve capable of operating at higher differential pressures by maintaining a zero differential pressure on the seat.
The VXZ series is a 2 port, pilot operated solenoid valve capable of operating at higher differential pressures by maintaining a zero differential pressure on the seat.
The VXZ series is a 2 port, pilot operated solenoid valve capable of operating at higher differential pressures by maintaining a zero differential pressure on the seat.
(But, only the mounting bracket for the above models is assembled at the time of shipment.)
Note 3) Use at a speed within the absorption capacity range. Refer to page 1211.
Reference formula [Dynamic moment at impact] Use the following formulae to calculate dynamic moment when taking stopper impact into consideration. : Collision speed (mm/s) L1: Distance to the load,s center of gravity (m) ME: Dynamic moment (Nm) g: Gravitational acceleration (9.8 m/s2) m: Load mass (kg) F: Load (N) FE: Load equivalent to impact (at impact with stopper) (N) a: Average speed
If the mounting part of the body comes loose, tighten at the specified torque. For the recommended torque, please refer to the table below.
Therefore, if the cylinder's stroke is constrained by the use of an external stopper or the like, be aware that the cushion might not be applied at all.
Mount a switch at the center of the operating range. Adjust the mounting position of an auto switch so that the piston stops at the center of the operating range (the range in which a switch is ON). (The mounting positions shown in the catalog indicate the optimum position at stroke end.)
(page at left) Suffix -XB10 to the end of standard model no. (page at left) Rubber bumper is standard equipment for long stroke type. Part no. Mounting Bracket Part No. Intermediate strokes by the 1 mm interval are available by using spacers with standard stroke cylinders.
Calculation example Calculation for allowable external force (with moment load) When static load f = 10 N, which produces pitch moment to the point L = 30 mm from MRHQ16D guide, is applied. Operable condition requires that F be bigger than f.