Copper extension nozzle/KNL (mm) Model Nozzle size D Outside diameter L1 Weight (g) KNL3-06-150 KNL3-06-200 KNL3-08-200 KNL3-08-250 KNL3-10-250 KNL3-10-300 KNL6-06-150 KNL6-06-200 KNL6-08-200 KNL6-08-250 KNL6-10-250 KNL6-10-300 1.5 2 2 2.5 2.5 3 1.5 2 2 2.5 2.5 3 6 6 8 8 10 10 6 6 8 8 10 10 300 300 300 300 300 300 600 600 600 600 600 600 43 43 61 61 94 94 84 84 117 117 183 183 O.D.
When washing the micromesh element, do not wipe it using a stiff brush or rag. 0.03 12 08 20 24 10 16 Pressure drop (MPa) 06 0.01 0.005 COM. N.O.
Metric size Inch size 3.2 01 03 05 07 09 11 23 04 06 08 10 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" Control type 4 6 8 10 0 1 Meter-out Meter-in Use 1/8" tube.
Max. 3.2 4 6 3.2 4 6 8 4 6 8 10 22.1 22.1 22.9 27.5 27.5 27.5 32.4 34.4 34.4 36.4 43.2 8.4 9.3 11.6 9.3 9.3 11.6 15.2 10.4 12.8 15.2 18.5 17.3 17.3 18.1 20.4 20.4 20.4 25.3 25.2 25.2 27.2 33.9 AS121FM-M5-23 AS121FM-M5-04 AS121FM-M5-06 AS221FM-01-23 AS221FM-01-04 AS221FM-01-06 AS221FM-01-08 AS221FM-02-04 AS221FM-02-06 AS221FM-02-08 AS221FM-02-10 12.7 12.3 7 25 25.8 22.2 9.6 28.6 M5 x 0.8 8
Note) Available for the rubber seal type only. 23 Manifold Specification Sheet Series VQC2000: Base-Mounted Type/Plug-in Unit How to order manifolds VV5QC 2 1 08 FD1 B C8 F P T Kit / / 1 2 3 8 VV5QC 2 1 08 SDQ B C8 S Kit Fill out for I/O serial kit only.
Dept. code 24 Manifold Specification Sheet Series VQC2000: Base-Mounted Type/Plug-in Unit q How to order manifolds VV5QC 2 1 08 FD1 B C8 F P T Kit / / 1 2 3 8 VV5QC 2 1 08 SDQ B C8 S Kit Fill out for I/O serial kit only.
ZFB100, ZFB101 ZFB200, ZFB201 ZFB300, ZFB301 ZFB401 16 x 14 x L60 rZFB200-08 tZFB300-08, -10 ZFB301-11, ZFB401-13 I-34S-A 10 x 6 x L33 12 x 8 x L42 14 x 10 x L45 I-35S-A I-36S-A I-39S-A 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. 10 pcs. yZFB401-13 Note) Elements and O-rings for the cover are sold in sets of 10 pieces each. 10 pcs.
-196H-V 06 to 08 AL-197H-V 10 to 12 FKM-70 or EPDM-70 AL-198H-V Phosphoric ester 16 AL-199H-V 20 to 24 AL-200H-V 28 to 32 AL-201H-V Note) The material of seals (AL-196H-V to AL-201H-V) is EPDM-70.
Model K VCKL0604-02F H KFN-06-X2 K VCKL0806-02F H KFN-08-X2 K VCKL1075-02F H L Union nut C3604BD + Ni plated 1 1 set unit KFN-10-X2 K VCKL1008-02F H K VCKL1209-02F H KFN-12-X2 K VCKL-02F H K VCKL0604-02F H KFS-06 K VCKL0806-02F H KFS-08 K VCKL1075-02F H M Sleeve Nylon 1 1 set unit KFS-10 K VCKL1008-02F H VNA VNB K VCKL1209-02F H KFS-12 SGC SGH N Gasket VCKK-4-1 Nylon 1 10 set unit VNC VNH
ZR ZM Symbol 1 Pad dia. 02 to 08 ZH 2 10 to 16 3 20 to 32 4 40, 50 ZU ZL T 1 ZP A5 [qAdaptor] ZF ZP With Buffer ZCU Vacuum related T ZP 16 K20 A10 06 UGN [Pad model no.] Symbol Thread dia. 1 A8 Buffer connection thread Symbol Pad dia. 2 A10 2 10 to 16 B5 3 20 to 32 3 A14 4 40, 50 B8 T 2 ZP B5 [qAdaptor] Not used for 02 to 08 diameter.
3.54 in / 90 mm, Width: 1.65 in / 42 mm, Height: 1.65 in / 42 mm, Net Weight: .55 lbs. / .25 Kg Series Configured Datasheet.
Specifications Air 1.5 MPa 1 MPa 0.05 MPa 5 to 60C (No freezing) Fluid Proof pressure Max. operating pressure Min. operating pressure Ambient and fluid temperature How to Order Symbol AS 42 0 02 Option Body size Nil None 42 50 60 80 90 1/2 standard 3/4 standard 1 standard 1 1/4 standard 1 1/2 standard High temperature (5 to 80C) Low temperature (30 to 60C) H (1) Bore size Bore size Applicable
Round head combination screw DXT199-23-4 M3 x 26 Round head combination screw M3 x 8 Round head combination screw VK300-33-3 Blanking plate VK3000-7-1 Manifold gasket VK3000-6-1 Manifold gasket VK3000-6-2 Manifold gasket for blanking plate VK3000-6-3 Applicable base Type VV5K3-20 Type VV5K3-21 Manifold base Applicable base VK3000-9-1 Sub-plate Type VV5K3-40 Type VV5K3-(S)41 Type VV5K3-(S)42
H 28 30 36 44 54 E 22 21 26 F 45 55 58 65 76 G 33 42 44 50 61 D 34 46 63 67 78 A 59 78 107 110 134 B 20 29 39 42 53 C 40 53 70 75 90 I 45 55 63 69 81 Model Piping port VHS20 VHS30 VHS40 VHS40-06 VHS50 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1938 Series VHS20/30/40/50 Specific Product Precautions Be sure to read before handling.
30.5 32.5 30 50 50 41 42 48 44.5 47.5 43.5 36.5 38.5 36 63 56.5 47.5 48.5 54.5 51 54 50 40 42 39.5 10-10-13 14 Series RZQ Mounting of Auto Switch Follow the procedures below to mount auto switches.
A + Stroke 20Data Common Dimensions: MVGPM/MVGPL B C DA FA FB G GA GB H HA IA IB Extension locking Retraction locking IC Standard stroke (mm) Bore size (mm) ID IE IF IG IH J K L 20 25 32 9.5 10 9 79.5 10 10 12 32.5 8.5 9 9 26.5 36 40 49 M5 x 0.8 6.5 7 8 21.2 18 21 24 10 12 16 36 42 48 10.5 37 83 93 112 6 7.5 9 24 30 34 M5 M5 M6 32 18 21 24 3 20, 30, 40, 50, 75, 100, 125 150, 175, 200,
17.5 42 62 M14 x 2 35 M12 x 1.75 Bore size OA OB OL P PD PE PW Q R S T U VA WA X YY YL Z Nil TN TF 80 (56 x 2) 10.6 17.5 10 Rc1/4 NPT1/4 G1/4 24.5 23 37 38 64 55 155 118 184 25.5 42 M12 x 1.75 18 9.5 100 (71 x 2) 12.5 20 12 Rc1/4 NPT1/4 G1/4 31.5 25 38 40 74 71 187 141.5 219 27.5 46 M14 x 2 21 11 9 JMGP Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at stroke
Thread NPT Hex Part Number Weight (grams) Bag/Box Quantity D1 D2 D3 D4 L1 L3 3/8 3/8-18 22.23 KV2KF11-36 17.9 21 5.4 42 100/200 18.1 17.9 18.2 26.2 28.2 52.4 8 Series KV2 Male Run Tee KV2Y_ _-_ _S D2 Applicable Tube A D1 L1 Applicable Tube B MA MB L3 D5 D6 A L2 Hex Thread D3 D4 A* MA Min. Flow Dia. App. A Tube OD (inch) App. B Tube OD (inch) Thread NPT Hex Part Number D1 Wt.
Dimensions AS420 AS500 AS600 67.5 74 90 1/4, 3/8, 1/2 3/4 1 38 42 55 122 115 158 112 105 148 50 50 62 L1 L2 L4 Min.
No.PF-OMM0004-D / / PF3W7## SMC 2 11 13 14 16 17 19 21 24 26 26 F1 OUT1 60 F2 OUT2 36 F3 42 F10 43 F20 47 F22 48 F30 50 F80 51 F81 52 F82 53 F90 54 F98 55 F99 56 57 61 61 65 65 71 79 81 88 -1No.PF-OMM0004-D (ISO/IEC) (JIS) 1 2 1) ISO 4414:Pneumatic fluid power -General rules relating to systems.