Type 40 Easy manual operation Since manual overrides are located in 2 directions, on the top and on the side of the valve, manual override operation is possible unaffected by mounting space and piping direction, etc. Ozone resistant (Series 80-) FKM (fluororubber) is used for the fluidcontact rubber materials, allowing use even in ozone environments.
ZSE50F / ISE50 1 x 10 -5Pam3/s ZSE60F / ISE60 1 x 10 -10Pam3/s IP65 Enclosure Panel mount With bracket Option Panel mount + Front side protection cover To confirm working pressure of hydraulic cylinder Application examples To confirm adsorption of work pieces containing water To confirm primary pressure of cleaning line Features 1 High precision and high resolution 1/2000 (0.1kPa) Positive
How to Find the Flow Rate (At air temperature of 20C) Choke flow: (P2 + 0.1)/(P1 + 0.1) ) 0.5 293 273 + t Q = 120 x S x (P1 + 0.1) x Subsonic flow: when (P2 + 0.1)/(P1 + 0.1) > 0.5 Q = 240 x S x (P1 P2)(P2 + 0.1) x 293 273 + t Q: Air flow rate [ /min (ANR)] S: Effective area (mm2) P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] t: Air temperature [C] Note 1) Formulas above are
(mm) Connection thread R(PT) S (Width across flats) Weight (g) Bracket ass'y No.
Fl 20 stafrons r (Not mounled) Base mounted / Type 40 (A porl: bottom porting) NVV3KF3-40-OD.01T stations^ --'11--t -o Applicable valves NVKF334O OOO Applicable blank plate ass'y vK300-42-1A 2 stations oplional accessory .
Valve r opens through the stem, and the outlet pressure is released to the inlet side (Figure 2). 707 Series ARP20/30/40 Dimensions 2 x P1 (Port size) A Pressure gauge (Option) Q C OUT IN K V P2 (Pressure gauge port size) B R Bleed port F S U D N Bracket (Option) J M T Panel fitting dimension Y W Plate thickness ARP20(K), ARP30(K): Max. 3.5 ARP40(K): Max. 5 OUT IN Z Pressure Gauge Option
Valve r opens through the stem, and the outlet pressure is released to the inlet side (Figure 2). 765 ARP20/30/40 Series Dimensions 2 x P1 (Port size) A Pressure gauge (Option) Q C OUT IN K V P2 (Pressure gauge port size) B R Bleed port F S U D N Bracket (Option) J M T Panel fitting dimension Y W Plate thickness ARP20(K), ARP30(K): Max. 3.5 ARP40(K): Max. 5 OUT IN Z Pressure Gauge Option
Type L Type S Type L Type S/Type L 5 8 13 12 20 23 6/Rc 6/Rc 24 34 46 40 70 78 8/Rc 10/Rc 5 8 13 12 20 23 24 34 46 40 70 78 55 75 95 65 110 150 85 135 185 SUP VAC EXH 28 28 33 66 11 12 16 27 43 55 95 ZH ZH07B ZH10B ZH13B ZH05D ZH07D ZH10D ZH13D ZH15D ZH18D ZH20D 1 8 1 8 Box type (Built-in silencer) 0.7 1.0 1.3 0.5 0.7 88 48 1 4 1 8 ZU Courtesy of Steven Engineering, Inc.-230 Ryan Way, South
Example) 10-ARP30K-03BE-1RY Clean room compliant, copperfree, fluorine-free, silicon-free Clean room compliant Copper-free, fluorine-free Symbol 20 30 40 Body size Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without
XLH-16 XLH-25 XLH-40 XLH-50 16 25 40 50 5150 -6 Pa (abs) 110 l/s 1 5 14 45 80 10 FKM1.310 3/s Pam -11 FKM1.310 KFNW SUS316L,FKM Nm 0.1 0.15 0.35 0.5 5 7 10 13 0.23 0.41 1.05 1.62 1) 3-2.
(Not including sensor accuracy), Response time: 150 ms or less Accuracy (To display value) (25C) 1.0% F .S. or less 1.5% F .S. or less 2.0% F .S. or less PF2 0.5% F .S.
Heater specifications Item XL-25 XL-40 Rated voltage of the heater 90 to 240 ACV Heater assembly number XLA25-60S-1 No. of heater assemblies 1 pc. H 4 S y m b o l consumption (W) 100 VAC 200/40 Initial power / Power 200 VAC 800/40 Heater assembly number XLA25-60S-1 XLA25-60S-2 No. of heater assemblies 1 pc. 1 pc.
180 Angular Type Air Gripper Rack & Pinion Type MHW2 Series 20, 25, 32, 40, 50 How to Order M9BW 20 MHW2 D 1 Made to Order Refer to page 712 for details. 2 fingers Number of fingers 2 Number of auto switches Bore size 20 25 32 40 50 Nil 2 pcs. 20 mm 25 mm 32 mm 40 mm 50 mm S 1 pc. n n pc.
Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. 16 Series PB1000 Process Pump Built-in Solenoid Valve Type/Air Operated Type Performance Curves/Built-in Solenoid Type/Air Operated Type 1l/min = 0.035SCFM 1MPa = 145psi Cycle 1Hz Cycle 5Hz Cycle 10Hz 70 70 70 60 60 60 50 50 50 40 40 40 Total lifting range m Total lifting
Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. 16 Series PB1000 Performance Curves/Built-in Solenoid Type/Air Operated Type Cycle 1Hz Cycle 5Hz Cycle 10Hz 70 70 70 60 60 60 50 50 50 40 40 40 Total lifting range m Total lifting range m Total lifting range m SUP=0.7MPa SUP=0.7MPa SUP=0.7MPa SUP=0.5MPa SUP=0.5MPa SUP=0.5MPa
Nil C 0.4 to 4 L/min 1.8 to 20 L/min 4 to 40 L/min The cable and connector are shipped unassembled.
The value of the effective area S, like that of sonic conductance C, expresses the ease of flow. (3) Formula for flow rate When P2 + 0.1 0.5, choked flow P1 + 0.1 293 Q = 120 x S (P1 + 0.1) (3) 273 + t When P2 + 0.1 > 0.5, subsonic flow P1 + 0.1 293 Q = 240 x S (P2 + 0.1) (P1 P2) (4) 273 + t Conversion with sonic conductance C: S = 5.0 x C(5) Q : Air flow rate [dm3/min (ANR)], dm3
to 100 mm2/s Hydraulic fluid 40 to 100 mm2/s DIN terminal DIN terminal with light/surge voltage suppressor Caution CE-compliant This product cannot be used for water application.
SRF 1 07 11 0 S S 1 With nut Body size 1 3 5 Fitting type Pilot port thread type Made to Order (Refer to page 887 for details.)
(Ms) Tgpe 40 Manifold,/ Bottom Ported(External Pilot) inch (mm) Grommet (c), (H) (ln case ol lo-3zNorn, (M5)) L type plug connector(L) 13.78 (s50) 13.,13 (s41) r3.19 (35) Symbol (internal pilot tpe) N.C. N.O. slJrb s-zrJh P R P R w (external pilot type) N.C. N.O. A A , $TJ-b SZI;TF P R P B Model '.6NPTF 0.26 (130) 0 4 8 .,6. ].