G MADE IN IDF100150F-W i.2 i-6 IDX-OM-Z004 i i.3 HFC IDF100150F-W i.3 i-7 IDX-OM-Z004 i i.4 / 1 1.5 () IDF100150F-W i.4 / i-8 IDX-OM-Z004 1 1 1.1 i.2.9 1 2 IDF100F-30-W C,RV IDF100F-30-CRVW4 IDF 100 F 30 W 4 C 5 G ) K 100kW 100 P 125kW 125 150kW 150 R ) V AC200V(50Hz) AC200/220V(60Hz) 30 1 4 5 C G K P R V 1.1 IDF100150F-W 1 1 IDX-OM-Z004 1 1.2 1.2.1 (C) 1.2.2 G 1.2.3
When 40 m is rquired: 1-40 2 If indicating 7 only, the filtration rate is 5 m. Optional filtration rate is required, indicate like 17-. Ex.) When requiring stainless steel and 40 m; 17-40 3 The bowl of series AL is used. 4 This symbol indicates the port size.
SW RESET RUN2 RUN1 OV INPUT 6 7 5 8 4 + 9 3 SET UP A 2 B 1 0 C D 1 E F 0 to 10V V R 1 OUTPUT SET UP BALANCE CONTROLLER VYU5-D 2 V R 2 OV ERR.
Flow Direction Symbols on Body Meter-out type Meter-in type Symbol JIS Symbol 15-9-57 2 Series AS-FM How to Order AS 2 2 0 1 F M 01 06 Body size Option 1 2 M5 standard 1/8, 1/4 standard Nil S None With seal M5 and U10/32 are not available with seal. Type 2 3 Elbow Universal Applicable tubing O.D.
Seal kit includes a grease pack (6, 10: 5 and 10 g, 15 to 40: 10 g). Order with the following part number when only the grease pack is needed. Grease pack part no. for 6, 10: GR-F-005 (5 g) for external sliding parts, GR-S-010 (10 g) for tube interior Grease pack part no. for 15 to 40: GR-S-010 (10 g) 113
GR-S-010(10g )GR-S-020(20g ) (XC85,X446)P25 1 2 3 4 8 1 100 83(g) L100mm 1 2 1mm 8. 8. g 20 25 32 40 100st 2 3 3 34 50st 0.5 0.5 0.5 1 20 3-2-4. 1) 8, 9 2 ( 8,) 10 3( 8,) 1mm 9. 10. 3-3. CG1/CG1*A 3-3-1. 20 25 32 40 CG1N20Z-PS CG1N25Z-PS CG1N32Z-PS CG1N40Z-PS GR-S-010(10g) (10g) 1 GR-S-010 (10g) GR-S-020 (20g) 1 21 3-3-2. 22 3-4. 1.
3.4 . 14 (1) . 14 (2) . 14 4. . 15 4.1GW (B RATE) . 15 4.2 (CN2SW) . 16 4.3LEC . 16 4.4GW EtherNet/IP . 22 5. . 26 5.1 CN4 . 26 5.2 CN3 . 26 5.3 CN1CONT . 26 5.4 CN2PC/TB . 27 6.CN4 . 28 1 - 6.1 . 28 6.2 . 29 6.3 . 30 . 30 7.CN1(CONT) . 31 7.1 . 31 7.2 . 33 8.CNTB/PC . 34 8.1 . 34 9.LED . 35 9.1LED . 35 9.2 LED . 35 10. . 36 10.1 . 36 10.2 . 37 10.3 . 37 11.4 . 39 11. . 40
Free flow Controlled flow Model Applicable cylinder bore size (mm) Effective area (mm2) Weight (g) Port size Flow rate (/min (ANR)) Flow rate (/min (ANR)) Flow rate (/min (ANR)) AS2000E-01 AS2000E-02 AS3000E-02 AS3000E-03 AS4000E-02 AS4000E-03 AS4000E-04 90 1/8 1/4 1/4 3/8 1/4 3/8 1/2 340 5.2 250 3.8 20, 25, 32, 40 115 32, 40, 50, 63 810 12.3 810 12.3 130 40, 50, 63 80, 100 1670 25.5 1670
32, 40, 50, 63 124 AS3000-03 3/8 810 12.3 810 12.3 221 AS4000-02 1/4 1,670 25.5 1,670 25.5 40, 50, 63 80, 100 214 AS4000-03 3/8 1,670 25.5 1,670 25.5 205 AS4000-04 1/2 1,670 25.5 1,670 25.5 242 AS5000-02 1/4 2,840 44 2,840 44 40, 50, 63 80, 100 233 AS5000-03 3/8 4,270 66 4,270 66 224 AS5000-04 1/2 4,270 66 4,270 66 AS4000 Note) Flow rate values are measured at 0.5 Mpa and 20C.
The vacuum aspiration fluence shows the fluence immediately before piping in the actuator. 5 - 3.How to Order 11LEJS 40 A 500 S2 1 10 9 8 7 4 5 3 2 6 *1 (2) Motor type (3) Lead [mm] (1) Size 40 LEJS40 LEJS63 Output [W] Actuator size Compatible controller Type 63 16 A 20 AC servo motor (incremental encoder) S2 10 8 B LECSA-S1 40 100 (5) Motor option AC servo motor (incremental encoder) S3
,B RATE) . 15 4.2(CN2SW) . 15 4.3(LEC) . 16 5. . 18 5.2 CN3 . 18 5.3 CN1CONT . 18 5.4 CN2PC/TB . 19 .CN4 . 20 6.1 . 20 6.2 . 20 6.3 . 21 1 - . 22 7.CN3 . 23 8.CN1IF(CONT) . 24 8.1 . 24 8.2 . 26 9.CN2TB/PC . 27 9.1 . 27 10.LED . 28 10.1 LED . 28 10.2IFLED . 28 11. . 29 11.1 . 29 11.2 . 29 11.3 . 29 11.4 . 31 12. . 32 12.1 . 32 12.2 IF(IN Data) . 38 12.3 (IN Data) . 38 12.4(OUT Data) . 40
INFORMATION Compact Guide Cylinder With Flange 12, 16, 20, 25, 32, 40, 50, 63, 80, 100 Plate side flange type added.
Float style auto-drain (N.O.) 8 93 Thread Rc(PT) NPT G(PF) N F Port size 1 4 12 14 20 1 1 1 2 Indicate the required filtration rate after the symbol "1". Ex.) When 40m is required: 1-40 If indicating "7" only, the filtration rate is 5m. Optional filtration rate is required, indicate like 17-l. Ex.)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L2 (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C
, Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)
Output pressure (kPa) 40 0 0 Out 60 0.5 0.5 80 1.0 1 0 2 4 6 8 10 0 25 50 75 100 0 25 50 75 100 Input signal (%F.S.) Count Input signal (%F.S.)
Actuator operation from host . 40 8.1 CiA 402 drive profile . 40 8.1.1 FSA state . 40 8.1.2 Controlword / Statusword . 41 8.1.3 Control mode . 42 8.2 Parameter setting . 43 8.3 Servo-on and Homing . 44 8.4 Positioning operation (Profile position mode) . 45 9.
at 40 mA) Current leakage 100 A or less at 24 VDC Indicator LED Red LED illuminates when turned ON.
MADE IN G IDF100150F i-2 i-6 IDX-OM-U021 i i-3 HFC IDF100150F i-3 i-7 IDX-OM-U021 i i-4 / 1 1.5 () IDF100150F i-4 / i-8 IDX-OM-U021 1 1 1-1 i.2.9 1 2 IDF100F-30 C.RV IDF100F-30-CRV1 IDF 100 F 30 C 1 2 G 3 K 100 125 150 ) 100kW 125kW P 150kW ) R V 30 AC200V(50Hz) AC200/220V(60Hz) 1 C 1 G 2 K 3 P R V 1-1 IDF100150F 1 1 IDX-OM-U021 1 1-2 1-2-1 (C) 1-2-2 G 1-2-3 K
Compact Cylinder with Solenoid Valve/ Guide Rod Type 32, 40, 50, 63 Series CVQM How to Order CVQM 32 30 M9BW 5 M Port thread type 32 40 M5 x 0.8 Bore size 32 40 50 63 Nil 32 mm 40 mm 50 mm 63 mm Rc G NPT 50 63 F N Piping Nil P Standard Axial Cylinder stroke (mm) Refer to the next page for Standard Stroke and Intermediate Stroke.