VER VEA 5 (R1) 4 (A) 1 (P) 2 (B) VY2 OFF state VBA VBAT F1 < F2 condition: See figure q. 2 (B) 3 (R2) AP100 4 (A) ON state Immediately after turning on F1 > F2: See figure e.
(q 85 l/min., e 93 l/min.) Condition 2. P1 = 0.7 MPa, P2 = 0.2 MPa Refer to curve B when P is 0.5 MPa. Ex) At increasing current, the flow rate when 150 mA current is applied is 65 l/min. (See r.) If the outlet pressure P2 increases by 0.15 MPa, P decreases by 0.15 MPa and becomes 0.35 MPa (See curve C), and the flow rate when the same current is applied is 40 l/min. (See t.)
Example) 10-ARP30K-03BG-1RY Clean room compliant, copperfree, fluorine-free, silicone-free Clean room compliant Symbol Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without mounting option With bracket With set nut (For
Example) 10-ARP30K-03BG-1RY Clean room compliant, copperfree, fluorine-free, silicone-free Clean room compliant Symbol Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without mounting option With bracket With set nut (For
For Deionized Water and Chemical Liquids Digital Flow Switch PF2D Series RoHS How to Order Remote Type Sensor Unit PF2D5 13 20 1 C Flow rate range Option (Refer to page 391.) 04 20 40 None e-con connector x 1 pc. Nil C 0.4 to 4 L/min 1.8 to 20 L/min 4 to 40 L/min The cable and connector are shipped unassembled.
T Y Applicable tubing O.D. 2 U R E ) Plug: KJP 02 Variation Male connector Extended male elbow Different diameter union "Y" KJH KJW KJU Male branch tee Plug-in reducer Hexagon socket head male connector KJT KJR KJS Union tee Bulkhead union Straight union KJT KJE KJH Male run tee Plug Different diameter straight KJY KJP KJH Union "Y" Male elbow KJU KJL 1
None Thread type Nil Rc F G N NPT T NPTF Body size Port size B Bracket (VEX312 only) Body size Port size Port 1(P), 2(A), 3(R) 12 01 1/8 02 1/4 Rated voltage VEX312 VEX332 1 100 VAC (50/60 Hz) 2 200 VAC (50/60 Hz) 3 110 VAC (50/60 Hz) 4 220 VAC (50/60 Hz) 5 24 VDC 6 12 VDC V 6 VDC S 5 VDC R 3 VDC * DC specification of type D and DO is only available with 12 and 24 VDC. 32 02 1/4 03 3/8 04
VEA 5 (R1) 4 (A) 1 (P) 2 (B) VY2 OFF state VBA VBAT F1 < F2 condition: See figure q. 2 (B) 3 (R2) AP100 4 (A) ON state Immediately after turning on F1 > F2: See figure e. Thereafter F1 = F2: See figure w. 4 (A) 1 (P) 2 (B) 3 (R2) Inw, port 3(R) is half open. 705
DC 5 6 24 VDC 12 VDC Port size AC (50/60 Hz) Symbol Port size VP300 1/8 1/4 3/8 1/2 VP500 VP700 1 2 3 4 7 B 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] 240 VAC 24 VAC 01 02 03 04 Made to Order Nil Electrical entry Pilot exhaust port with piping thread (M3) specification (Refer to page 24).
Pilot valve symbol 1 2 3 4 5 6 100 AC 200 AC 110 AC 220 AC 24 DC 12 DC q w e r t y u i Nil Y Nil Y Nil Nil Nil Nil K1 K1 J1 J1 Q1 Q2 N1 N2 Combinations (1) to (8) in the above table are the only possible options. 850
Material: E (Aluminum Cover, SPCD Case, NBR Gasket/O-ring, Nylon/Fluororesin Seal), Element Length: A (ℓ250), Port Size: 04 (1/2 Rc), Element Type: M (Micromesh, Stainless Steel 304/Epoxy Material), Nominal Filtration Accuracy: 5 μm, Element Seal Material: N (NBR), Accessory: B (Bracket)
Size: 4 (40), Body Material: S (Stainless Steel), Seal Material: E (EPDM), Port Size: 04 (1/2), Thread Type: N (NPT), Rated Voltage: 5 (24 VDC), Electrical Entry: DZ (DIN Terminal w/Light, w/Surge Voltage Suppressor), Oil Free Option: None, Bracket: B (with Bracket)
Body Size: 40, Back Flow: K (w/Backflow), Thread: F (G), Port Size: 04 (1/2), Mounting Option: Without Mounting, Float Type Auto Drain Option: D (N.O.
Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Mounting: None, Float Type Auto Drain: D (N.O.
Body Size: 40, Backflow: K (w/Backflow Function), Thread: N (NPT), IN Port Size: 04 (1/2), OUT Port Size: 03 (3/8), Options: E (Square Embedded Type Pressure Gauge, w/Limit Indicator), Set Pressure: 1 (0.02 to 0.2 MPa Setting, Exhaust Mechanism: Relieving Type, Knob: Downward, Pressure Unit: Z (Unit on Product Label: psi, Pressure Gauge: MPa/psi Dual Scale)
Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: VA (CC-Link - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP), Valve Stations: 04 Stations, P, E Port Location: D (D Side), SUP/EXH Block: Internal Pilot, A, B Port Size: C6 (ø6 One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate, w/o Station Number)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Stations: 04 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: E (Vacuum Break Flow Adjusting Needle, Screwdriver Operation
Stations: 04 (Stations), Wiring: L (Individual Wiring or None), Manifold Options: D [with Common Release Pressure Supply (PD) Port], Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: K (Pressure Switch for Vacuum w/Energy Saving Function, -100 to 100, NPN 2 Outputs, with Unit Selection Function), Leadwire: W (Energy Saving), Unit Options: E (Vacuum Break Flow
Stations: 04 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: E (Digital Pressure Switch for Vacuum, -100 to 100, NPN 2 Outputs, with Unit Selection Function), Leadwire: without Leadwire, Unit Options: without Option, 1st Nominal Nozzle Size: 4 (ø1.5), 1st Selection Supply Valve and