Pressure gauge indication range GC3-4A-X2102 0 to 0.4 MPa MPa GC3-10A-X2102 0 to 1.0 MPa End block Option GC3-P4A-X2102 0 to 60 PSI PSI Nil 3 None GC3-P10A-X2102 0 to 150 PSI End block type Oil-free Specifications Mounting position Symbol L R Note 1) Since the L side end block is oil-free, leave the field blank for it.
Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 170 0.5 1.0 0.6 0.2 0.1 1.0 0.6 0.2 0.1 0.1 4.5 15 0.61 2.5 10.45 0.75 1 4 250 (8A) 26 41 46 15 26 41 58 58 1.1 1.7 1.9 0.61 1.1 1.7 2.4 2.4 3.3 6.4 8.8 2.5 3.3 6.4 11 11 0.50 0.40 0.40 0.45 0.50 0.40 0.38 0.38 1.1 1.8 2.3 0.75 1.1 1.8 2.8 2.8 6 8 1.5 0.4 340 10 4.5 6 8 250 1.0 3 8 (10A
VVFS4000-10A 1 pc. 3.2-23 VFRA4000 Dimensions 2 position single: VFRA4111-03 04 2 position double: VFRA421103 04 SlA VlA SlA VlA VM/VR VH 03 04 03 04 03 04 3 position closed center: VFRA43113 position exhaust center: VFRA44113 position pressure center: VFRA45113.2-24
mm2) Model IN 2 0 VXA2132 0 VXA2122 0 VXA2132 0 VXA2232 0 VXA2242 0 VXA2252 0 VXA2262 0 VXA2232 0 VXA2242 0 VXA2252 0 VXA2262 0 VXA2262 0 6 1.0 0.5 1.0 1.0 0.33 0.61 0.33 3 4.5 3 VXA212 1 8 (6A) 11 6 170 Construction/Components 0.5 1.0 0.6 0.2 0.1 1.0 0.6 0.2 0.1 0.1 0.61 4.5 11 1 4 250 Normally closed (N.C.) (8A) 6 1.05 19 8 1.7 31 1.5 0.4 340 10 1.9 34 4.5 0.61 11 250 1.0 6 1.05 19 3 8 (10A
ModelMax. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Note)Weight (g) COM.Av x 10-6m2Cv converted3/8 (10A)3/8 (10A)4VX3244-030.2120.501.0530
ModelMax. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Note)Weight (g) COM.Av x 10-6m2Cv converted3/8 (10A)3/8 (10A)4VX3244-030.2120.501.0530
ModelMax. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Note)Weight (g) COM.Av x 10-6m2Cv converted3/8 (10A)3/8 (10A)2.2VX3324-0314.60.191.0730
ModelMax. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Note)Weight (g) COM.Av x 10-6m2Cv converted3/8 (10A)3/8 (10A)2.2VX3324-0314.60.191.0730
ModelMax. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Note)Weight (g) COM.Av x 10-6m2Cv converted3/8 (10A)3/8 (10A)3VX3334-030.67.90.331.0730
ModelMax. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Note)Weight (g) COM.Av x 10-6m2Cv converted3/8 (10A)3/8 (10A)3VX3334-030.67.90.331.0730
ModelMax. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Note)Weight (g) COM.Av x 10-6m2Cv converted3/8 (10A)3/8 (10A)4VX3344-030.3120.501.0730
ModelMax. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Note)Weight (g) COM.Av x 10-6m2Cv converted3/8 (10A)3/8 (10A)4VX3344-030.3120.501.0730
ModelMax. operating pressure differential (MPa)Flow characteristicsMax. system pressure (MPa)Note)Weight (g) COM.Av x 10-6m2Cv converted3/8 (10A)3/8 (10A)3VX3334-030.67.90.331.0730
Solenoid: No.1 Solenoid, Body Option: 3 (10A), Style: 0 (Energized Open/N.C.), Option: K (Stainless Steel Body & Shading Coil, PTFE Seal, Class B Coil), Port Size: 02 [1/4 (10A)], Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Lead Wire: G (Grommet), Surge Suppressor: S (Surge Suppressor)
Size: 2 [ø15(ø11)], Valve Type: 1 [NC (Operating Pressure 0.5MPa)], Sealant: NBR Seal, Body Material: Standard, Pilot System Option: Standard, Thread: NPT, Port Size: 3/8, Voltage: 24VDC, Lead Wire: Conduit Terminal w/Light & Surge Voltage Suppressor, Manual Override: Locking Style Slotted, Bracket: Bracket
Size: 2 [ø15(ø11)], Valve Type: 1 [NC (Operating Pressure 0.5MPa)], Sealant: NBR Seal, Body Material: Standard, Pilot System Option: Standard, Thread: NPT, Port Size: 1/2, Voltage: 110VAC 50/60HZ, Lead Wire: Conduit Terminal, Manual Override: Non-locking Push Style, Bracket: Bracket
Size: 2 [ø15(ø11)], Valve Type: 1 [NC (Operating Pressure 0.5MPa)], Sealant: NBR Seal, Body Material: Standard, Pilot System Option: Standard, Thread: Rc(PT), Port Size: 1/2, Voltage: 24VDC, Lead Wire: Conduit Terminal w/Light & Surge Voltage Suppressor, Manual Override: Non-locking Push Style, Bracket: Bracket
Size: 2 [ø15(ø11)], Valve Type: 1 [NC (Operating Pressure 0.5MPa)], Sealant: NBR Seal, Body Material: Standard, Pilot System Option: Standard, Thread: NPTF, Port Size: 1/2, Voltage: 110VAC 50/60HZ, Lead Wire: Conduit Terminal w/Light & Surge Voltage Suppressor, Manual Override: Non-locking Push Style, Bracket: Bracket
Size: 2 [ø15(ø11)], Valve Type: 1 [NC (Operating Pressure 0.5MPa)], Sealant: NBR Seal, Body Material: Standard, Pilot System Option: Standard, Thread: NPTF, Port Size: 3/8, Voltage: 12VDC, Lead Wire: DIN Terminal, Manual Override: Non-locking Push Style, Bracket: Bracket, X200: -, CE Compliance: -
Size: 2 [ø15(ø11)], Valve Type: 1 [NC (Operating Pressure 0.5MPa)], Sealant: NBR Seal, Body Material: Standard, Pilot System Option: Standard, Thread: NPT, Port Size: 3/8, Voltage: 24VDC, Lead Wire: DIN Terminal w/Light & Surge Voltage Suppressor, Manual Override: Non-locking Push Style, Bracket: Bracket, X200: -, CE Compliance: -