Do not operate with the magnetic coupling out of position. If the magnetic coupling is out of position, push the external slider by hand (or the position slider with air pressure) back to the proper position at the stroke end. 3. Do not apply a lateral load to the external slider.
Graph (4) v = 150 mm/s or less v = 200 mm/s or less Graph (7) Graph (8) 20 300 300 200 200 MGF100 MGF100 20 100 100 MGF100 MGF100 10 MGF100 MGF100 50 40 50 40 MGF63 Load weight m0 (kg) Load weight m0 (kg) MGF63 Load weight m (kg) Load weight m (kg) 30 30 MGF63 10 20 20 MGF63 5 10 10 MGF40 5 4 3 5 4 3 MGF40 MGF40 MGF40 5 MGF40 2 2 3 5 2 1 1 10 20 30 40 50 100 200 300 400 10 20 30 40 50 100
Do not use in an environment where flammable gas or explosive gas exists. Usage may cause a fire or explosion. The products do not have an explosion proof construction. 3. Do not use in a place subject to heavy vibration and/or shock. 1. Drain flushing Remove drainage from the air filters regularly. 2. Lubrication Once lubrication has been started, it must be continued.
Symbol Stations 02 20 20 2 stations 20 stations Specify the valve stations not exceeding the maximum stations. SUP/EXH block fitting spec.
Do not allow humans or objects to touch the ionizer while power is being supplied. Otherwise, the offset voltage may change or the HV LED may turn ON. 14. Do not make a rapid pressure change while power is being supplied to the ionizer. It will cause the NDL LED to turn ON. 15. Do not use this product in an enclosed space. This product utilizes the corona discharge phenomenon.
Refer to section [12.Dimensions] (p. 28 and p. 30) for necessary space. (3) Do not drop or apply impact during transportation or installation. Damage of products or pressure gauge can result in malfunction. (4) Do not install in areas with high humidity or high temperature.
Installation Warning (1) Do not drop or apply impact during transportation or installation. It will cause damage to the product and result in operation failure. (2) Do not install in areas of high humidity or high temperature.
The output OUT1(1) set value input mode is selected. 1: The set value of P1 is -50 Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.
Do not use the product in an environment where corrosive gases or fluids could be splashed. Otherwise damage to the product and malfunction can result. Do not use in an area where surges are generated.
Do not use the product in an environment where corrosive gases or fluids could be splashed. Otherwise damage to the product and malfunction can result. Do not use in an area where surges are generated.
Do not use any form of sealant other than the tape type of sealant. 3Winding of sealant tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not enter the piping.
Note) Do not pull on the lead wires with excessive force. This can cause faulty and/or broken contacts.
Adjustment bolt 25 mm adjustment bolt 8-16-20 20 Series CY1F Specific Product Precautions 2 Be sure to read before handing. Piping Handling Caution Caution 1. Do not inadvertently move the guide adjusting unit. The guide is installed at the proper tightening torque. Do not loosen the mounting bolts of the guide. 2.
Adjustment bolt 25 mm adjustment bolt 8-16-20 20 Series CY1F Specific Product Precautions 2 Be sure to read before handing. Piping Handling Caution Caution 1. Do not inadvertently move the guide adjusting unit. The guide is installed at the proper tightening torque. Do not loosen the mounting bolts of the guide. 2.
IO-Link DI DO StandardIO StandardIO 2 0x00 . 9-4 X0 X1 X2 X3 IO-Link 1 2 3 4 IO-Link 2 (I/Q) Bit 1 Bit 3 Bit 5 Bit 7 EX245-LA1 (EX245-LB1 0) 4 (C/Q) Bit 0 Bit 2 Bit 4 Bit 6 DO 2 4 (C/Q) Bit 0 Bit 2 Bit 4 Bit 6 DI() 9.5.
Do not connect. Caution Use a 3 wire NPN type for each switch. 18 19 20 Caution If input is not provided as prescribed for the operation, this may cause malfunction or failure. 311 Series LC6C Point Movement Home Position Return Operation With this driver, a maximum of 28 point positions can be set by combining banks and points.
Applicable in the programming function with up to 20 steps. Step 1 Step 2 Step 3 Step 4 Step 20 Step 5 . . . . . . . . . . . . .
3.13.6 Circulating fluid set temperature . 3-20 3.13.7 Operation instruction . 3-20 3.13.8 Data instruction . 3-21 Chapter 4 Communication alarm function . 4-1 4.1 COMMUNICATION ALARM OCCURS . 4-1 4.2 COMMUNICATION ALARM RESET . 4-2 4.3 SETTING METHOD . 4-2 HRLE Series HRX-OM-Z015 Chapter 1 Read before using Chapter 1 Read before using The communication of this product consists of contact
Do not operate in locations having an atmosphere of corrosive gases, chemicals, sea water, water or steam, or where there will be contact with the same. 2. Do not operate in locations where vibration or impact occurs. 3. In locations which receive direct sunlight, provide a protective cover, etc. 4. In locations near heat sources, block off any radiated heat. 5.