) Ambient and operating temperatures*4 Body material Resin 5 to 40C (0 to 40C) Stainless steel 5 to 80C (0 to 50C) Grease Grease-free Aluminum 12 27 48 110 193 Weight [g]*5 Body material Resin 7 17 30 67 119 Stainless steel 34 77 139 323 568 Pressure sensor*6 PSE541-M5-X2 (Grease-free) Rated pressure range: 0 to 101 kPa *1 Lifting force of the basic type at the max. supply pressure Values
Outlet temperature = 38.5 1.35 = 28.5C Mounting Ambient temperature (C) Caution Outlet Air Temperature 50C 70C 100C Inlet air temperature (C) Correction factor Air flow (l/min (ANR)) 1. Do not interchange the connections to the compressed air inlet and the compressed air outlet.
Inlet air temperature 50C is saturated air. At 70C or more, it is humid air with dew point 67C. JIS Symbol 14-15-5 2 Series HAW How to Order Precautions HAW 22 14 D Be sure to read before handling.
Operating temperature range 0 to 50C (with no freezing and condensation) Environmental resistance Operating humidity range Operating, Storage: 35 to 85% R.H.
N.O. 101.2 kPa to 0.2 VPA344 544 744 Pilot pressure (MPa) Ambient and fluid temperature (C) Lubrication Mounting orientation Impact/Vibration resistance (m/s2) Note) Same as operating pressure (Min. 0.2 MPa) 10 to 50C (No freezing. Refer to page 5-11-4.) Not required (Use turbine oil Class 1 lSO VG32, if lubricated.)
OUT2: Lights up when ON) Hysteresis mode Window comparator mode Hysteresis Note 4) Response time Output short circuit protection Display Display accuracy Indication light Analog output Auto shift input Note 2) Output voltage: 1 to 5V 5% F.S. or less Output voltage: 1 to 5V 2.5% F.S. or less Note 3) No-voltage input (solid state switch or reed switch), input 5ms or more IP65 Operating: 0 to 50C
(No freezing, heat cycle not applied) 0 to 50C (No freezing, heat cycle not applied) 1 to 10 Hz FLUID IN Air operated 0.2 Note 3) 0.18 kg 0.11 kg FLUID OUT port upside General environment 100 mPas 24 VDC 0.35 W Each of the values above are for normal temperatures and clear water.
Water (1 to 50C), Air, Heated water (80C) Note 3), Low vacuum (133 Paabs) Quick fastener type Fluid Air, Water (1 to 40C) Note 5), Low vacuum (133 Paabs) One-touch fitting type Note 4) Withstand pressure 1.0 MPa Valve specifications Coil specifications 10 to 50C Ambient temperature 1 to 50C (No freezing) Fluid temperature Ambient humidity RH85% Environment Location without corrosive or explosive
Ambient and fluid temperature operation is as follows: Digital pressure switches: 0 to 50C Other pressure switches: 0 to 60C Take measures to prevent freezing moisture in circuits when below 5C, since this may cause damage to the O-ring and lead to a malfunction. The installation of an air dryer is recommended for eliminating condensate and moisture.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0 to 1 MPa 0 to 101 kPa 100 to 100 kPa 0 to 500 kPa 0 to 1 MPa 0 to 101 kPa 0 to 101 kPa 101 to 101 kPa 0 to 101 kPa 100 to 100 kPa Set pressure range 12 to 24 VDC (Ripple p-p 10% or less) Voltage 2% F.S. or less (0 to 50C: based on 25C) 3% F.S. or less
) Hysteresis mode Window comparator mode Hysteresis Note 4) ZSP Response time Output short circuit protection Display Display accuracy Indicator light Analog output Auto shift input ISA2 IS Note 2) Output voltage: 1 to 5 V 5% F .S. or less Output voltage: 1 to 5 V 2.5% F .S. or less ZSM Note 3) No-voltage input (Solid state switch or reed switch), input 5 ms or more IP65 Operating: 0 to 50C
nozzle design S u c t i o n f l o w r a t e 4 0 % h i g h e r than traditional designs Silencer and suction filter Optional air supply and vacuum release valve Optional diaphragm or solid state vacuum switch Manifold mountable version T E C H N I C A L SPECIFICATIONS S Y M B O L S Fluid Air Max Operating Pressure 7 Bar / 100PSI Supply Exhaust Operating Pressure 2 ~ 5.5 Bar / 30~80PSI 5 ~ 50C
) 2% F.S. or less (Total) (0 to 50C) 3% F.S. or less (0 to 50C) Total of controller and sensor Total of controller and sensor 0.5% F.S. or less (Total) Hysteresis mode: Variable Window comparator mode: Fixed (3 digits: ISE5B/6B) (2 digits: ZSE5B/6B) Digit is min. calibration unit.
Metal seal Rubber seal Single 0.15MPa 0.1MPa 2 position double (double solenoid) Valve specifications Solenoid specifications Double (latching) 0.18MPa 0.18MPa (A) 4 (B) 2 (A) 4 (B) 2 Minimum operating pressure Double (double solenoid) 0.1MPa 0.1MPa 3 position 0.2MPa 0.1MPa 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) Metal seal Rubber seal 4 position 0.15MPa 3 position closed center 10 to 50C
style and/or special voltage, consult SMC. 1.12-34 VQZ1000/2000/3000 Base Mounted Standard Specifications Metal seal Seal Rubber seal Air, lnert gas Fluid Air, lnert gas 0.7MPa (High pressure type: 1.0MPa) Max. operationg pressure 0.15MPa Single Double 2 position Min. operating pressure 0.1MPa only for VQZ3000, 3 position 0.15MPa Valve specifications 0.1MPa 3 position 0.2MPa (1) (1) 10 to 50C
Effective oil level stroke (mm) Converter nominal size/stroke (mm) 50, 100, 200, 300, 400, 500 100, 200, 300, 400, 500, 600 200, 300, 400, 500, 600, 700, 800 63 100 160 Specifications Operating pressure 0 to 0.7 MPa Proof pressure 1.05 MPa 5 to 50C Ambient and fluid temperature Fluid Turbine oil (40 to 100 mm2/s) Converter Standard Effective Oil Level Stroke/Effective Volume (cm3) Converter
Note 2)) 5 to 50C Note 1) (Air operated type: 60C) Pressure range External pilot air Lubrication Temperature Unrestricted Note 3) Mounting orientation Note 1) No freezing Note 2) Lubrication is not allowed for use with EPR seal material. Note 3) For external pilot solenoid, it is recommended that the pilot solenoid valve be oriented either vertically upward or horizontally.
Air Operated only) Ambient temperature External pilot solenoid VNB0 B C 2 1 1 2 5 to 50C Note 1) (Air operated type: 60C) 1.5 MPa Low vacuum to 0.5 MPa Low vacuum to 1 MPa 0.25 to 0.7 MPa 0.1 + 0.25 x (Operating pressure) to 0.25 + 0.25 x (Operating pressure) MPa Note 3) Refer to Graph (1) on page 568. Not required (Use turbine oil Class 1 ISO VG32, if lubricated.
Lubrication Temperature Allowable voltage fluctuation Not required (Use turbine oil Class 1 ISO VG32, if lubricated.) 5 to 50C (Air operated type: 60C) Note 1) SGC 35C or less (when rated voltage is applied.) 50C or less (when rated voltage is applied.)
Pilot Operated Solenoid Valve Specifications VO307D DZ1(-Q) DIN terminal Pilot solenoid valve Electrical entry Coil rated voltage (V) AC (50/60 Hz) DC 100 V, 200 V, Other voltage (Semi-standard) 24 V, Other voltage (Semi-standard) 15 to +10% of the rated voltage Allowable voltage fluctuation Temperature rise 50C or less (When rated voltage is applied.)