Symbol Nil N F Option Option Symbol Applicable actuation Built-in solenoid valve Air Operated PB1013A Air operated Port size Port size 1/8 Nil B N None With foot With silencer Symbol 01 When option is more than one, suffix in alphabetical order.
How to Order Integrated Display Type M PF2A7 10 01 27 Flow rate range 1 to 10 l/min 5 to 50 l/min 10 to 100 l/min 20 to 200 l/min 50 to 500 l/min 10 50 11 21 51 Thread type Unit specification Nil M With unit switching function Fixed SI unit Note) Nil N F Lead wire (Refer to page 35.)
Panel mount adapter ZS-46-B Panel mount adapter + Front protection cover ZS-46-D Lead wire with connector ZS-46-3L 3-core, 2 m, Non-waterproof (Without waterproof cover) Front protection cover ZS-27-01 D Panel mount adapter + Front protection cover ZS-46-D R1/8 Piping adapter ZS-46-N1 NPT1/8 Piping adapter ZS-46-N2 9
AR425 to 935 ARX q Body size 1 2 3 Symbol Description AMR w Set pressure range 0 0.005 to 0.2 MPa V V 0.01 to 0.2 MPa V 1 0.01 to 0.4 MPa V V V 2 0.01 to 0.8 MPa V V V + ARM ARP IR-A IR-A e Exhaust direction 0 Bottom exhaust V V V 1 Front exhaust V 2 Rear exhaust V + IR IRV r Pipe thread type Nil Rc V V V N NPT V V V F G V V V + VEX 01 1/8 V 02 1/4 V V 03 3/8 V 04 1/2 V + SRH
AR425 to 935 ARX q Body size 1 2 3 Symbol Description AMR w Set pressure range 0 0.02 to 0.2 MPa V V V 1 0.02 to 0.4 MPa V V V 2 0.02 to 0.8 MPa V V V + ARM ARP e Exhaust direction 0 Bottom exhaust V V V 1 Front exhaust V 2 Rear exhaust V + IR-A IR-A IR r Pipe thread type Nil Rc V V V N NPT V V V F G V V V + IRV VEX 01 1/8 V 02 1/4 V V 03 3/8 V 04 1/2 V + SRH t Port size SRP a
VM100F Series How to Order VM1 3 R 1 F 06 30 Bracket option Number of ports Nil None B With bracket (included) Sufx for indicator 2 2-port 3 3-port Nil None Applicable only to side ported Twist selector (3-position), plunger (straight, roller, cross roller), toggle lever type cannot be mounted. These are only for panel mount type.
Nil T F N Rc NPTF G NPT Refer to page 43 for ordering coil only. Suffix Oil-free Nil Z Electrical entry Select Nil because the solenoid valve V, M options are oil-free treatment. G-Grommet C-Conduit Port size Refer to Table (1) shown below for availability.
Panel mount adapter ZS-46-B Panel mount adapter + Front protection cover ZS-46-D Lead wire with connector ZS-46-3L 3-core, 2 m, Non-waterproof (Without waterproof cover) Front protection cover ZS-27-01 D Panel mount adapter + Front protection cover ZS-46-D R1/8 piping adapter ZS-46-N1 NPT1/8 piping adapter ZS-46-N2 7
Size: 01 (Size 01), Passage Symbol: FG (2 Position Double), Number of Solenoids: S (Single), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: R (Rubber Seal), Port Size: A02 (Side Ported, 1/4), Thread: F (G)
Size: 01 (Size 01), Passage Symbol: FG (2 Position Double), Number of Solenoids: S (Single), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: Metal Seal, Port Size: A02 (Side Ported, 1/4), Thread: F (G)
Size: 01 (Size 01), Passage Symbol: FIG (3 Position Pressure Center), Number of Solenoids: D (Double), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: Metal Seal, Port Size: A01 (Side Ported, 1/8), Thread: F (G)
Size: 01 (Size 01), Passage Symbol: FG (2 Position Double), Number of Solenoids: S (Single), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: Metal Seal, Port Size: A01 (Side Ported, 1/8), Thread: F (G)
Size: 01 (Size 01), Passage Symbol: FJG (3 Position Exhaust Center), Number of Solenoids: D (Double), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: Metal Seal, Port Size: A02 (Side Ported, 1/4), Thread: F (G)
Size: 01 (Size 01), Passage Symbol: FJG (3 Position Exhaust Center), Number of Solenoids: D (Double), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: R (Rubber Seal), Port Size: A02 (Side Ported, 1/4), Thread: F (G)
Size: 01 (Size 01), Passage Symbol: FG (2 Position Double), Number of Solenoids: D (Double), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: Metal Seal, Port Size: A02 (Side Ported, 1/4), Thread: F (G)
Size: 01 (Size 01), Passage Symbol: FJG (3 Position Exhaust Center), Number of Solenoids: D (Double), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: R (Rubber Seal), Port Size: w/o Sub-plate, Thread: F (G)
Size: 01 (Size 01), Passage Symbol: FHG (3 Position Closed Center), Number of Solenoids: D (Double), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: Metal Seal, Port Size: A01 (Side Ported, 1/8), Thread: F (G)
Size: 01 (Size 01), Passage Symbol: FHG (3 Position Closed Center), Number of Solenoids: D (Double), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: Metal Seal, Port Size: A02 (Side Ported, 1/4), Thread: F (G)
Size: 01 (Size 01), Passage Symbol: FG (2 Position Double), Number of Solenoids: D (Double), Rated Voltage: 3 (24 VDC), Light/Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor), Sealing Type: R (Rubber Seal), Port Size: A02 (Side Ported, 1/4), Thread: F (G)
Size: 01 (Size 01), Port Size: A01 (Side-ported 1/8), Thread: F (G)