Max Operating Pressure: 3.5 MPa, Construction: Element Upward Removal, Threaded, Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: Differential Press. Indication Switch, Construction 42 Only, Relief Valve: Relief Valve, Fluid: Water-glycol, Emulsion, Element: Micromesh, Filtration: 10μm, Fluid Direction: IN Right, Made to Order: Non-standard Filtration
Construction: Common w/L-type Thread & Flange, Port Size: 2, Pressure Indicator: Differential Pressure Indication Switch, Relief Valve: Relief Valve, Fluid: Water-glycol, Emulsion, Filtration: 105μm, Flange: -
Type: -, Type: Line filter, Hydraulic fluid: Water/glycol series, emulsion series, Connection Port Size: 3/4B, Nominal filtration(μm): 10, Differential pressure display: Differential pressure display switch, Relief valve: With Relief valve, O-ring nominal size: N/A, Structure / connection method: Screw-in, Operating pressure (max.)(MPa): 3.5, Element: Micro-mesh, Flow Direction: IN left,
Type: -, Type: Line filter, Hydraulic fluid: Water/glycol series, emulsion series, Connection Port Size: 3/4B, Nominal filtration(μm): 20, Differential pressure display: Differential pressure display switch, Relief valve: With Relief valve, O-ring nominal size: N/A, Structure / connection method: Screw-in, Operating pressure (max.)(MPa): 3.5, Element: Micro-mesh, Flow Direction: IN left,
Type: -, Type: Line filter, Hydraulic fluid: Water/glycol series, emulsion series, Connection Port Size: 3/4B, Nominal filtration(μm): 40, Differential pressure display: Differential pressure display switch, Relief valve: With Relief valve, O-ring nominal size: N/A, Structure / connection method: Screw-in, Operating pressure (max.)(MPa): 3.5, Element: Micro-mesh, Flow Direction: IN left,
Type: -, Type: Suction filter, Hydraulic fluid: Water/glycol series, emulsion series, Connection Port Size: 1 1/2B, Nominal filtration(μm): 105, Differential pressure display: Differential pressure display switch, Relief valve: With Relief valve, O-ring nominal size: N/A, Structure / connection method: L type screw-in / flange dual use, Companion flange: N/A, Related component type: N/A
Max Operating Pressure: 3 (3.5 MPa), Construction: 42 (Element Upward Removal, Threaded), Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: 5 (Differential Press. Indication Switch, Construction 42 Only), Relief Valve: 0 (Relief Valve), Fluid: 1 (Water-glycol, Emulsion), Element: M (Micromesh), Filtration: 105μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard
Max Operating Pressure: 3 (3.5 MPa), Construction: 42 (Element Upward Removal, Threaded), Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: 5 (Differential Press. Indication Switch, Construction 42 Only), Relief Valve: 0 (Relief Valve), Fluid: 1 (Water-glycol, Emulsion), Element: M (Micromesh), Filtration: 10μm, Fluid Direction: L (IN Right), Made to Order: X0 (Non-standard
Max Operating Pressure: 3 (3.5 MPa), Construction: 42 (Element Upward Removal, Threaded), Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: 5 (Differential Press. Indication Switch, Construction 42 Only), Relief Valve: 0 (Relief Valve), Fluid: 1 (Water-glycol, Emulsion), Element: M (Micromesh), Filtration: 10μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard
Max Operating Pressure: 3 (3.5 MPa), Construction: 42 (Element Upward Removal, Threaded), Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: 5 (Differential Press. Indication Switch, Construction 42 Only), Relief Valve: 0 (Relief Valve), Fluid: 1 (Water-glycol, Emulsion), Element: M (Micromesh), Filtration: 20μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard
Max Operating Pressure: 3 (3.5 MPa), Construction: 42 (Element Upward Removal, Threaded), Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: 5 (Differential Press. Indication Switch, Construction 42 Only), Relief Valve: 0 (Relief Valve), Fluid: 1 (Water-glycol, Emulsion), Element: M (Micromesh), Filtration: 40μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard
Construction: 90 (Common w/L-type Thread & Flange), Port Size: 16 (2), Pressure Indicator: 5 (Differential Pressure Indication Switch), Relief Valve: 0 (Relief Valve), Fluid: 1 (Water-glycol, Emulsion), Filtration: 105μm
Construction: 90 (Common w/L-type Thread & Flange), Port Size: 12 (1 1/2), Pressure Indicator: 5 (Differential Pressure Indication Switch), Relief Valve: 0 (Relief Valve), Fluid: 1 (Water-glycol, Emulsion), Filtration: 105μm
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Port Size: -, Differential Pressure Indication: -, Relief Valve: -, Hydraulic Fluid: -, Element: -, Filtration: -, Made to Order: -
pressure: 0.5 MPa Inlet pressure: 0.5 MPa 100 200 3 400 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 6 Effective area (mm2) Effective area (mm2) Effective area (mm2) 06, 08 08, 10 1.0 300 06 04 2 4 50 100 200 0.5 1 2 100 0.0 0 0 0 0 0 0 5 10 0 5 10 0 5 10 Number of needle rotations (turns) Number of needle rotations (turns) Number of needle rotations (turns) ASG520F
cF , 06, a8 010 0 10 012 rv,iIljme:tersi~e 06 08 08 01 /4" Tube out&ide . Inch' size I0 1/4" 03/8' 05/16" 05/16" diameter . . 03/S' 051160 1/2" Flbw."rate tlin\~ 330 750 350 C ,oP/rolled flow . (A,MR~~N '(lmjQ' . 180 600 1100 1190 [Ereo flaw) Effettive ~IOnal 11.6 17 2.9 5.2 18.4 5.4 9.3 'ttrea mm 2 .
Note) 1/2 standard Metric size 23 04 06 08 10 12 Inch size Made to Order Refer to page 608 for details. 3.2 01 03 05 07 09 11 13 1/8" With One-touch fittings 4 5/32" Caution 6 3/16" 8 1/4" Be sure to read before handling.
With One-touch fitting Port size U01 Uni 1/8 U02 Uni 1/4 U03 Uni 3/8 U04 Uni 1/2 Needle Valve/Flow Rate Characteristics AS2201F-U02, AS2211F-U02 AS2301F-U02, AS2311F-U02 AS2201F-U01, AS2211F-U01 AS2301F-U01, AS2311F-U01 600 300 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 06, 07, 08, 09, 10 500 08, 09, 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) 03, 04 06, 07 200 400 01, 23 300