Function: 1 (2 Position Single), Body Option: 4 (Non plug-in, Individual Electrical Entry), Option: 1 (Direct Manual Override), Pilot: R (External Pilot), Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: B (Locking Slotted Style), Piping: Side, Port Size: 04 (Sub-plate 1/2), Thread: T (NPTF)
Series: AF, Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Mounting: Standard, Float Type Auto Drain: w/o Auto Drain, Bowl Type: 2 (Metal Bowl), Bowl Guard: None, Drain Port: J (Drain Guide 1/8: Body Size 20; Drain Guide 1/4: Body Size 30, 40), Indicator: without Indicator, Flow Direction: R (Right to Left), Drain Cock w/Barb Fitting: None, Pressure Unit: Z (Pressure Unit: psi; Temp
Size 20; Drain Guide 1/4: Body Size 30, 40), Exhaust Mechanism: Relieving Type, Flow Direction: R (Right to Left), Drain Cock w/Barb Fitting: None, Pressure Unit: Z [Product: psi, °C; Pressure Gauge: psi (and MPa)]
Port: J (Drain Guide 1/8: Body Size 20; Drain Guide 1/4: Body Size 30, 40), Exhaust Mechanism: Relieving Type, Flow Direction: R (Right to Left), Drain Cock w/Barb Fitting: None, Pressure Unit: Z [Product: psi, °C; Pressure Gauge: psi (and MPa)]
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT) Speed controller standard in-line style; Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2; Port sizes: M3, M5, 01, 02, 03, 04
Function: 1 (2 Position Single), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: R (External Pilot), Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: F (Plug-in), Surge Suppressor: None, Manual Override: C (Locking Knob Style), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 04 (Sub-plate Plug-in Terminal 1/2, Non Plug-in Standard 1/2), Thread
Function: 1 (2 Position Single), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: R (External Pilot), Voltage: 5 (24VDC), Lead Wire: F (Plug-in), Surge Suppressor: None, Manual Override: C (Locking Knob Style), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 04 (Sub-plate Plug-in Terminal 1/2, Non Plug-in Standard 1/2), Thread: T (NPTF)
Rated Flow Range: 501 (5 to 500 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: M (SI Unit Only), Option 2: R (w/Bracket)
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04 FLOW CONTROL. SPEED CONTROLLER. 105.00000 lb. SVD.
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: JT (OUT1: Analogue 1 to 5 V - OUT2: Analogue 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket: R
Actuation Type: 1 (2 Position Single), Sealant: 0 (Metal Seal), Function: R (External Pilot), Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 04 (Rc1/2), Thread: T (NPTF)
Actuation Type: 3 (3 Position Closed Center), Sealant: 1 (Rubber Seal), Function: R (External Pilot), Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 04 (Rc1/2), Thread: N (NPT)
Flow Rate Range: 501 (5 to 500 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: C (NPN; Analog 1 to 5 V), Option 1: w/Lead Wire w/Connector, Unit Specifications: M (SI Unit Only), Option 2: R (With Bracket), Calibration Certificate: A (With Calibration Certificate)
Function: 1 (2 Position Single), Body Option: 0 (Base Mounted Plug-in), Direct Manual Override: 0 (Standard), Pilot: R (External Pilot), Voltage: 5 (24VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 04 (Sub-plate Plug-in Terminal 1/2, Non Plug-in
Body Size: 40, Thread: N (NPT), Port: 04 (1/2), Option: CE (C + E), Attachment: S (Pressure Switch), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: RZ (R + Z)
Rated Flow Range: 501 (5 to 500 L/min), Thread Type: Rc, Port Size: 04 (1/2), Output Specifications: A (Out 1: NPN; Out 2: NPN), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: M (SI Unit Only), Option 2: R (w/Bracket)
Flow Rate Range: 102 (10 to 1000 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: C (NPN; Analog 1 to 5 V), Option 1: w/Lead Wire w/Connector, Unit Specifications: Unit Selection Function, Option 2: R (With Bracket)
Flow Rate Range: 102 (10 to 1000 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: C (NPN; Analog 1 to 5 V), Option 1: W (w/Lead Wire w/Connecter + Connector Cover), Unit Specifications: Unit Selection Function, Option 2: R (With Bracket), Calibration Certificate: A (With Calibration Certificate)
Flow Rate Range: 102 (10 to 1000 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: E (PNP; Analog 1 to 5 V), Option 1: W (w/Lead Wire w/Connecter + Connector Cover), Unit Specifications: Unit Selection Function, Option 2: R (With Bracket), Calibration Certificate: A (With Calibration Certificate)
Flow Rate Range: 102 (10 to 1000 L/min), Thread Type: Rc, Port Size: 04 (1/2), Output Specifications: E (PNP; Analog 1 to 5 V), Option 1: W (w/Lead Wire w/Connecter + Connector Cover), Unit Specifications: M (SI Unit Only), Option 2: R (With Bracket)