SMC Corporation of America
Elite Part Number Search
Search Results "11-CDA2F63TN-100"

No code 0 V3 L 1 H 2 4 No gauge port No pressure gauge Ports -30 in.Hg to 30 psig -30 in.Hg to 60 psig -30 in.Hg to 100 psig -30 in.Hg to 160 psig 0 to 200 psig 0 to 400 psig -0.1 to 0.2 MPa -0.1 to 0.4 MPa -0.1 to 0.7 MPa -0.1 to 1.1 MPa 0 to 1.4 MPa 0 to 3 MPa Code Ports 2 ports 3 ports 2PW 3PW Porting Configuration e w q w q 1) Other range available.

8.2 115 2 60 3.1 80 5.6 100 8.2 115 2 60 3.1 80 5.6 100 8.2 115 2 60 Equivalent size Note 1) No freezing Note 2) This product cannot be used for water applications.

N.O. 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz Note) N.O. valve operates properly only when appropriate pressure is applied to the pilot.

Max. operating frequency 10 Hz Lubrication Manual override Non-locking push type Mounting orientation Unrestricted 150/50 m/s2 Impact/Vibration resistance (2) Dustproof Enclosure Grommet, Conduit, Conduit terminal, DIN terminal 100, 200, 110 , 220 , 240 Electrical entry DC AC (50/60 Hz) Coil rated voltage (V) 24, 12 15 to +10% of rated voltage 19 VA (50 Hz), 16 VA (60 Hz) 11 VA (50 Hz),

Note: AMG does not remove water vapour & air leaving AMG is 100% saturated. Where dehumified air (ie. RH<100%) is required an SMC dryer is recommended. Heavy Duty Auto Drain Model ADH 4000-N04 Minimum operating pressure 8psi. Maximum operating pressure 145psi. Maximum discharge 400cc/operation.

Stainless Steel Cylinder Series CJ5-S/Series CG5-S 10, 16 20, 25, 32, 40, 50, 63, 80, 100 For use in environments with water spray such as food processing machines Stainless Steel Cylinder Series CJ5-S/Series CG5-S Series CJ5-S/Series CG5-S Series CJ5-S/Series CG5-S 10, 16 20, 25, 32, 40, 50, 63, 80, 100 Uses grease for food processing machines that meets FDA (U.S.

Ol5 (M5) o.z 0r5 -oz -Body ported {wjth bracket} NVKF332Y {Low watlaqe: 2WDC) NVKF332V {Vacuum) l Ton-100 PSI (-100 KPa-o.7 MPa) NVKF332W tLow wattaoe + Vacuuml 0.181 lbs (80 s0 NVKF333 0-100 PSI {0-0.7 MPa) NVKF333Y ilow waltaqe: 2WDC) NVKF333V (Vacuum) 1 Torr"100 PSI (-100 KPa-0.7 MPa) NVKF333W ilow wattaoe + Vacuuml 2 position srngre solenoid (for maniiold) 0r5 NVKF334 0 ' 1 0 0 P S I

Supply: PneuAlpha accepts 100-240 VAC or 24 VDC Power Supply for use anywhere in the World. High Current Relay Outputs: Switch currents up to 10 amps with PneuAlphas heavy duty relays. Transistor Outputs: Fast switching, long life Outputs. 100-Hr Capacitor Backup for memory and RTC: PneuAlpha can retain its memory for 100 hours after a power outage.

Ol5 (M5) o.z 0r5 -oz -Body ported {wjth bracket} NVKF332Y {Low watlaqe: 2WDC) NVKF332V {Vacuum) l Ton-100 PSI (-100 KPa-o.7 MPa) NVKF332W tLow wattaoe + Vacuuml 0.181 lbs (80 s0 NVKF333 0-100 PSI {0-0.7 MPa) NVKF333Y ilow waltaqe: 2WDC) NVKF333V (Vacuum) 1 Torr"100 PSI (-100 KPa-0.7 MPa) NVKF333W ilow wattaoe + Vacuuml 2 position srngre solenoid (for maniiold) 0r5 NVKF334 0 ' 1 0 0 P S I

mm2/s Hydraulic fluid 40 to 100 mm2/s DIN terminal DIN terminal with light/surge voltage suppressor Caution CE-compliant This product cannot be used for water application.

Description Note 11 Additional air blow pulse operation time set switch Continuous (no pulse)/50 ms/100 ms 12 Cover for valve maintenance Used when replacing the built-in valve 13 Terminal block Signal output/External input/COM+/COM14 AC adapter (DC plug) entry 15 ON/OFF switch for dust collector 3 Regulator for adjusting supply pressure to the dust collector With pressure gauge 4 Regulator

T0604 How to Order T 0604 B 20 Max. operating pressure Max. operating pressure Color Length per roll Nylon tubing 20 20 m 100 m roll (Black, white only) Symbol Color B W R BU Y G Operating temperature (C) Black White Red Blue Yellow Green 100 Tube size Maximum operating pressure is 1/3 max. of burst pressure at 60C, considering the safety ratio.

Smooth Cylinder Minimum 0.01 to 0.03 MPa operating pressure Minimum Minimum 0.01 to 0.03 MPa operating pressure 0.04 Minimum operating pressure MPa 12 16 0.03 20 25 32 40 0.02 50 63 80 100 0.01 0 0 10 20 30 40 60 50 70 80 90 100 Bore size mm (Measurement based on JIS B8377) Series CQSY/CQ2Y/CM2Y/CG1Y/CA2Y 12 to 25 32 to 100 20 to 40 20 to 100 40 to 100 Stable operation possible even at a

S o.o t o.t 0.0 25 50 75 Inpul signal (%F.S.) o 25 50 75 100 InPUt signa ("/.F.S.)

The start-up of the power-saving type unit is set to take 100 msec. This valve should be in the ON position after the energizing time of 100 msec. or longer. Solenoid valve part number Allowable voltage range [Ambient and fluid temperatures: 5C or higher and 40C or lower] LPV21-mm-T4 LPV21-6mm-T6(A) LPV22-mmm-T4A LPV22-mmm-T6A 7.

Metric sizes 6 8 10 12 ASS Flow rate l/min (ANR) Controlled 100 180 230 260 390 460 660 790 920 1580 1710 ASR (free) flow Effective area mm2 1.5 2.7 3.5 4 6 7 10 12 14 24 26 Note) Flow rate values are at a pressure of 0.5MPa, and temperature of 20C.

200 3 400 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 6 Effective area (mm2) Effective area (mm2) Effective area (mm2) 06, 08 08, 10 1.0 300 06 04 2 4 50 100 200 0.5 1 2 100 0.0 0 0 0 0 0 0 5 10 0 5 10 0 5 10 Number of needle rotations (turns) Number of needle rotations (turns) Number of needle rotations (turns) ASG520F-03 ASG521F-03 ASG620F-04 ASG621F-04 Inlet

Lock keys ( ref er t o P11) M i ni m um pressure ( F_1) adj ust i ng range M axi m um pressure ( F_2) adj ust i ng range 100% 100% 50% 0% 10% 0% 20m A 20m A 5V 10V 20m A 20m A 5V 10V 4 0 0 0 12 10 2. 5 5 4 0 0 0 12 10 2. 5 5 ( N ot e 1) : F_1 i s adj ust abl e i n a range f rom 0 t o 50% of t he rat ed val ue. ( N ot e 2) : F_2 i s adj ust abl e i n a range f rom 10 t o 100% of t he rat ed

Lock keys ( ref er t o P11) M i ni m um pressure ( F_1) adj ust i ng range M axi m um pressure ( F_2) adj ust i ng range 100% 100% 50% 0% 10% 0% 20m A 20m A 5V 10V 20m A 20m A 5V 10V 4 0 0 0 12 10 2. 5 5 4 0 0 0 12 10 2. 5 5 ( N ot e 1) : F_1 i s adj ust abl e i n a range f rom 0 t o 50% of t he rat ed val ue. ( N ot e 2) : F_2 i s adj ust abl e i n a range f rom 10 t o 100% of t he rat ed

, 125 140, 160, (180, 200) Basic, Foot, Flange Hydraulic cylinder 3.5 MPa or less 20, 25, 32, 40, 50, 63, 80, 100, 125 140, 160, (180, 200) JAH Series (Heavy load) Hydraulic cylinder 7 MPa or less 40, 50, 63, 80, 100 Basic, Foot, Flange Refer to the Web Catalog or Best Pneumatics.