: Vertical upward When a value has been displayed, it will be automatically reset when the pump is stopped.
A quick recovery time indicates little liquid pool.
L1 L2 L3 L4 M d Effective orifice (mm 2) Weight (g) A O.D.
Series VMG Conditions: Working condition Impact pressure of 0.02 MPa is ensured at a distance of 50 mm. Supply pressure VMG: 0.3 MPa Nozzle size Conventional model: 4 VMG: 2 Proposal for energy saving pneumatic system P/A supports innovation of the production system based on energy saving as a key word.
Refer to CAT.E824-A "Pressure Switch" for details on switches.
The mist then coagulates to form a large drop, becomes separated from the compressed air, accumulates in case r , and is discharged through the drain valve. Meanwhile, the clean compressed air in housing w passes through flow hole A of body q , it is reduced to a specified pressure by the pressure reducing valve, and is discharged from the OUT. !
Able to control and set a constant speed easily.
SOL.b SOL.a Digital vacuum pressure switch SOL.c 2 indicates the dimension when spacer A is mounted.
IN side, OUT side 4 10 22 20 22 30 30 50 30 75 39 75 39 Recommended air flow Tubing size Model ZFB100-04 ZFB100-06 ZFB200-06 ZFB200-08 ZFB300-08 ZFB300-10 6 6 8 8 10 Unrestricted 360 piping tube mounting. The connector for the IN side is a universal joint type that enables a tube to be connected in any direction within 360.
L4 L4 L5 A L5 D3 D3 T T D2 L1 D2 L1 L2 L2 AS ASP Metric Size ASN A M1 L5 Max.
Although the body of the sensor may not be damaged, the inside of the sensor could be damaged and lead to a malfunction. 2. The tensile strength of the cord is 20 N. Applying a greater pulling force on it can cause a malfunction. When handling, hold the body of the sensor do not dangle it from the cord. 3. Do not exceed the screw-in torque of 3.5 Nm when installing piping.
The element can be replaced with a single touch.
Bore sizes: 6, 10, 15, 20, 25, 32, 40, 50, 63; Stroke lengths: 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1500, 3000, 5000 mm; Minimum operating pressure: 0.12 ~ 0.16 MPa (17 ~ 23 psi); Speed: 50 ~ 500 mm/sec.; Options include: Heat Resistance 150°C (XB6), Low Speed, 15 ~50 mm/sec (XB9), Ultra Low Speed, 7 ~ 50 mm/sec (XB13), High Speed, 1500 mm/sec (X160),
Bore sizes: 6, 10, 15, 20, 25, 32, 40, 50, 63; Stroke lengths: 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1500, 3000, 5000 mm; Minimum operating pressure: 0.12 ~ 0.16 MPa (17 ~ 23 psi); Speed: 50 ~ 500 mm/sec.; Options include: Heat Resistance 150°C (XB6), Low Speed, 15 ~50 mm/sec (XB9), Ultra Low Speed, 7 ~ 50 mm/sec (XB13), High Speed, 1500 mm/sec (X160),
Note 2) -X138 has a stroke adjustable range of 12.5 mm on one side. Table (1) Air-hydro/Piston Speed Plate mounting Housing mounting Model CX2H15 CX2H25 Refer to the below. Note 1) 5 to 50 mm/s 5 to 40 mm/s 5 to 100 mm/s Note 1) Consult with SMC when the air-hydro type is mounted on a plate.
Resin Body SYJ (A) 2 Aluminum/NBR Spool valve w Pilot valve VK e 1 (P) 3 (R) VQZ100-12A Resin/Aluminum P, R plate r r VZ VT VQZ200/300 VT Metal seal Rubber seal VP r e w q r e w q VG VP VQ VQZ N.C. N.C. VZ (A) 2 (A) 2 VS 3 (R) 1 (P) 3 (R) 1 (P) r e w q r e w q N.O. N.O. (A) 2 (A) 2 3 (R) 1 (P) 3 (R) 1 (P) Component Parts Material Description Notes No.
Auto Switch Proper Mounting Position (Detection at Stroke End) A B Proper Mounting Position (mm) Bore size A B 40 63 100 32.5 0 16 0 27.5 0 Note) The above mentioned values are indicated as a guide for auto switch mounting positions for stroke end detection.
Select the point of contact A of inlet pressure and max. air capacity in the graph. 2. AME650 is obtained when the max. flow line is above the point of intersection A in the graph. Note) Make sure to select a model that has the maximum flow rate line above the obtained intersecting point.
(2) Model d T Weight (g) H D1 D2 L1 L2 L3 L5 (1) A (2) D3 L4 Max.
Runoff space 2 mm or more Mounting bracket , Note) Use a watchmaker s screwdriver with a grip diameter of 5 to 6 mm to tighten the set screws (M2.5). The tightening torque should be 0.05 to 0.1 Nm. As a rule, it should be turned about 90 beyond the point at which tightening can be felt. Auto Switch Mounting Bracket Part No. Auto switch part no.