C 0.2 B 0.2 A 0.2 Hexagon socket head mounting screws D Bore size (mm) A (mm) B (mm) C (mm) MGPM MGPL W 20 12 54 14 M5 x 0.8 24 72 25 18 15 M6 x 1.0 64 82 30 B 32 22 18 M8 x 1.25 98 34 78 A A 40 18 22 40 86 M8 x 1.25 106 50 22 110 27 M10 x 1.5 46 130 B W 63 27 22 M10 x 1.5 124 142 58 B: Retraction locking F: Extension locking 80 33 28 M12 x 1.75 180 54 156 100 33 39 62 188 M14 x 2.0 210 23
C 0.2 B 0.2 A 0.2 Hexagon socket head mounting screws D Bore size (mm) A (mm) B (mm) C (mm) MGPM MGPL W 20 12 54 14 M5 x 0.8 24 72 25 18 15 M6 x 1.0 64 82 30 B 32 22 18 M8 x 1.25 98 34 78 A A 40 18 22 40 86 M8 x 1.25 106 50 22 110 27 M10 x 1.5 46 130 B W 63 27 22 M10 x 1.5 124 142 58 B: Retraction locking F: Extension locking 80 33 28 M12 x 1.75 180 54 156 100 33 39 62 188 M14 x 2.0 210 23
(Normally closed) A N.O.
7 N@4 CL1 A' A A' A MLGC CNG B MNB @5 !5 CNA CNS 20, 25: 50 stroke or less Over 100 stroke CLS CLQ Extension locking (Type F) Retraction locking (Type B) MLGP N#2 u #6 y @2 u #6 #2 y #5 @2 i i RLQ MLU ML1C D-X Section B-B' Section B-B' 20Section A-A' !6 !6 Section A-A' Data Component Parts Description Material Note No. !7 !8 !
When using as a stopper, select a model with 30 stroke or less for bore sizes 20 and 25, and 50 stroke or less for bore sizes 32 to 100. 2. When selecting a model with a longer l dimension, be sure to choose a bore size which is sufficiently large.
Hs D-A44 A A 49.5 Auto switch 376 Auto Switch Mounting CH2E/CH2F/CH2H Series Auto Switch Proper Mounting Positions CHQ D-G5/K59 D-G5W/K59W D-G59F/G5BA D-G5NT D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-F5/J59 D-F5W/J59W D-F59F/F5BA Note2) D-A9/A9V Bore size (mm) D-G39/K39 D-A5/A6 D-B5/B64 D-A3/A44 D-F5NT D-A59W D-B59W CHK CHN A A A A A A A A A A A 32 25 21.5 26.5 17 15 19 15.5 18.5 CHM 40 26 22.5
When air with high purity is required, please either mount the above separator on the outlet side or use a made-to-order product (refer to page 14-19-50), which is provided with a micro mist separator (Series AWD) instead of a regulator. 3.
A Station 1 1 SOL. A Station 2 14 SOL. A Station 3 2 VQD 1 SOL. A Station 4 14 15 2 SOL. A 15 3 3 4 5 6 7 8 9 10 11 12 13 Station 5 16 17 18 19 20 21 22 23 24 25 SOL. B 16 SOL. A 4 Station 6 SOL. B DIN rail mounting bracket [-D] VVQ1000-57A for {F, L, M, P, S (EX500) kit} VVQC1000-57A-S for {S (EX250) kit} VVQC1000-57A-T for {T, S (EX126) kit} 17 SOL. A 5 Station 7 SOL. B 18 SOL.
Diaphragm B moves to the right, and at the same time diaphragm A also moves to the right pushing pilot valve A. 3. When pilot valve A is pushed, air acts upon the switching valve, drive chamber A switches to a supply state, and the air which was in drive chamber B is exhausted to the outside. 4. When air enters drive chamber A, diaphragm B moves to the left pushing pilot valve B. 5.
Bulkhead female union P. 77 KCE Use for transit connection of a tube and a male screw for installation of panel. 74 Series KC Self-seal Fittings M5 Half union: KCH M5 Applicable tube O.D. (mm) Effective orifice(mm 2) Weight (g) A Thread R(PT) Part No. H (Hex.)
(Pitch) P=19 1/8 (A port) 21 46 Series SYJ700 Type 21R Manifold: Top Ported (External Pilot Type)/SS3YJ7-21RStations (-00) [ ] for AC Grommet (G) M5 x 0.8 (X port) 63.5 L2 L1 30.5 21.5 6 1.5 14 22.5 9.5 6 21.5 49 (DIN 50.3) 26 X P A A A A 43 71.2 [73.4] 2-5.5 (For mounting) R 1/4 (P, R port) 1/8 (A port) (Pitch) P=19 21 Manual override Approx. 300 (Lead wire length) (Station n) (Station
fitting R1/8, M5 x 0.8 2 1 6 One-touch fitting 5/32" One-touch fitting NPT1/8, M5 x 0.8 1/4" One-touch fitting M5 x 0.8 female thread is cut inside the pipe.
U1 2 [With external pilot] (Pitch) P = 10.5 2n1-M5 x 0.8 [4(A), 2(B) port] 24 13.3 13.3 24 16.2 16.2 34 17 36.7 34 B 2 PE B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 R 3 R 3 P 1 1 P A 4 X A 4 A 4 A 4 A 4 4 A 4 A 4 A 4 A 4 A 2-One-touch fitting [1(P), 3(R) port] Applicable tube O.D.: 8 2-One-touch fitting (X, PE port) Applicable tube O.D.: 6 2n2-One-touch fitting [4(A), 2(B) port] Applicable tube
cable O.D.: 6.8 to 11.5) CE1 CE2 Proper Auto Switch Mounting Position D-H7 D-H7C D-H7NF D-H7W D-H7BAL D-C7 D-C80 D-C73C D-C80C ML2B D-G39 D-K39 D-A33/A34 D-A44 D-B5 D-B64 D-B59W D-G5NTL Bore size (mm) C J G5-S A B A B A B A B A B A B CV 20 56.0 31.5 50.0 25.5 55.0 30.5 51.5 27.0 53.0 28.5 49.5 25.0 25 MVGQ 56.0 31.5 50.0 25.5 55.0 30.5 51.5 27.0 53.0 28.5 49.5 25.0 32 59.5 36.5 53.5 30.5
To use a floating joint to connect the cylinder rod to a driven body, secure it in place by applying a torque that is appropriate for the thread size. Also, if there is a risk of loosening during operation, take measures to prevent loosening, such as using a locking pin or thread adhesive.
To use a floating joint to connect the cylinder rod to a driven body, secure it in place by applying a torque that is appropriate for the thread size. Also, if there is a risk of loosening during operation, take measures to prevent loosening, such as using a locking pin or thread adhesive.
Screw-in Piping M5 X 0.8 Relieving port size 50 to 500mm/s Piston speed Mounting Basic, Axial foot, Front flange, Rear flange *Auto switch attachable Dimensions REC B/Basic H2 2-Rc(PT)P Width across flats B2 2-NN G G H1 Width across flats B1 Relieving port M5 X 0.8 Standard port I Relieving port 2-Eh8 D MM AL K A N N F lNA S+Stroke H F ZZ+Stroke (mm) A AL B1 B2 D E F G H H1 H2 I K MM N NA
Clean appearance The flat cable provides wiring on a printed circuit board to the individual valves at the manifold base, enabling the consolidation of external wiring at a touch through a 26 pins MIL connector.
8 circuits 12 circuits 1 2 4 8 12 Options N/A Standard type FNote) Flange type Note: No flange type in 1 circuit system Options / Mounting bracket Number of circuits Flange part number 2 circuits MQR2-F 4 circuits MQR4-F 8 circuits MQR8-F 12 circuits MQR12-F Specifications Model MQR1-M5 MQR2-M5 MQR4-M5 MQR8-M5 MQR12-M5 Number of circuits 1 2 4 8 12 Operating fluid Air / Inert gas Seal structure