SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-L-P-01"

Model: 50 (Side Ported), Connector Type: P (Flat Ribbon Cable, 26 Pins), Connector Entry Direction: 1 (Upward), Wiring Specification: All Double Wiring, Valve Stations: 12 Stations, P, E Port Location: B (Both Sides), A, B Port Size: 01 (1/8), Thread: T (NPTF)

Model: 50 (Side Ported), Connector Type: P (Flat Ribbon Cable, 26 Pins), Connector Entry Direction: 1 (Upward), Wiring Specification: All Double Wiring, Valve Stations: 10 Stations, P, E Port Location: B (Both Sides), A, B Port Size: 01 (1/8), Thread: T (NPTF)

Please contact us for the latest version.sales@ocaire.com, E/P REGULATOR, VALVE, VY1 E/P REGULATOR, DA, VY1 BODY PORT 1/8, .66138 lb, ModelPort size RcWeight (kg) (1)Hysteresis (2)?Sensitivity ?Repeatability ?Response time ?

10%, Ripple (p-p) 10% or less (with power supply polarity protection)40 mA or lessNPN or PNP open collector 1 output, NPN or PNP open collector 2 outputs (selectable)80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms or less (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: 01 (R 1/8)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: 01 (R 1/8), Option 1: w/o Lead Wire, Option 2: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: 01 (R 1/8)

Please contact us for the latest version.sales@ocaire.com, E/P REGULATOR, VALVE, VY1 E/P REGULATOR, DA, VY1 BODY PORT 1/8, .00000 lb, ModelPort size RcWeight (kg) (1)Hysteresis (2)?Sensitivity ?Repeatability ?Response time ?

10%, Ripple (p-p) 10% or less (with power supply polarity protection)40 mA or lessNPN or PNP open collector 1 output, NPN or PNP open collector 2 outputs (selectable)80 mA28 V (at NPN output)1 V or less (with load current of 80 mA)2.5 ms or less (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?

Using the VVEXB/2/4 series, a maximum 10 station manifold is possible.Electro pneumatic regulator, Step-less control through electric signals, Simple circuit configuration, Internal or external pilot available, Base mounted or body ported styles, E/P REGULATOR, VALVE, VY1 E/P REGULATOR, MA, VY1 BASE MT Weight: tab 9

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: 01 (R 1/8), Option 1: w/o Lead Wire, Option 2: A1 (Bracket A, Vertical Mounting), Option 3: K (Operation Manual, Calibration Certificate)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: 01 (R 1/8), Option 1: w/o Lead Wire, Option 2: A1 (Bracket A, Vertical Mounting)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: 01 (R 1/8), Option 1: w/o Lead Wire, Option 2: None, Option 3: T (w/o Operation Manual, Calibration Certificate)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: 01 (R 1/8), Option 1: w/o Lead Wire, Option 2: B (Panel Mount Adapter)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: 01 (R 1/8), Option 1: w/o Lead Wire, Option 2: A2 (Bracket B, Horizontal Mounting)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: 01 (R 1/8), Option 1: w/o Lead Wire, Option 2: None, Option 3: K (Operation Manual, Calibration Certificate)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: 01 (R 1/8)

Please contact us for the latest version.sales@ocaire.com, E/P REGULATOR, VALVE, VY1 E/P REGULATOR, CA, VY1 BODY PORT 1/8 NPT, .59400 lb, ModelPort size RcWeight (kg) (1)Hysteresis (2)?Sensitivity ?Repeatability ?Response time ?

10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)0.6 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 2.4 to 20 mA ?2.5% F.S.?

Manifold with Stainless Steel Plate: S, Model: 51S (EX260), SI Unit: EAN (Negative Common, PNP; EtherNet/IPâ„¢; 32 Outputs; M12 Connector), Wiring Type: All Double Wiring, Valve Stations: 16 (16 Stations, All Double Wiring), Port Size: 01 [4(A)/2(B) Port: 1/8; 1(P)/3(EB), 5(EA) Port: 1/4], Thread Type: N (NPT), Option: P (Trim Plate)