a) (52) b) 28 c) (52) c) (16) e) (16) f) (/) g) () h) () i) j) k) l) m) -19No.EX-OML0010CN-C 4.
Output impedance: 1 k DS: Analogue output 4 to 20 mA Max. load impedance 600 Min. load impedance: 50 NPN (1 output) + External input type PF3A7##H-CS/DS#-##-# Maximum applied voltage: 28 VDC Maximum load current: 80 mA Internal voltage drop 1 V max. External input: Input voltage of 0.4 V max.
Power and output cable (ZS-26-A) Sensor connector ZS-28-C ZS-28-CA-42No.PF-OMH0003-F Revision history A: Full scale revision due to the change of the format and addition of items. B: Content is changed due to the change of the format. C: Contents revised in several places. D: Contents are added. E: Contents revised in several places. [July 2018] F: Contents revised in several places.
NPN + Analogue voltage output type NPN + Analogue current output type LFE0C LFE0D Max.28 V, 80 mA Internal voltage drop 1 V max. Analogue output 1 to 5 V Output impedance 1k Max.28 V, 80 mA Internal voltage drop 1 V max.
water inlet *3 Rc1/2 28 to 30Nm 1.0MPa or more.
Table 3-10 Piping port size Description Port Recommended Recommended piping size*1 tightening torque specifications Circulating fluid outlet port Rc1/2 28 to 30Nm 1.0MPa or more Circulating fluid return port Rc1/2 28 to 30Nm 1.0MPa or more Facility water inlet port *2 Rc3/8 22 to 24Nm 1.0MPa or more (Supply puressure: 0.3 to 0.5MPa) Facility water outlet port *2 Rc3/8 22 to 24Nm 1 For NPT
MRQB32,40 18 1 17 2 16 2 34 2 15 1 33 O 1 14 1 32 4 13 2 31 2 12 O 1 30 1 11 2 29 1 10 1 28 S 1 9 1 27 S 1 8 O 2 26 1 7 1 25 2 6 1 24 4 5 1 23 4 4 1 22 4 3 1 21 O 3 2 1 20 O 1 1 1 19 1 12 14 2 28 1 13 2 27 1 12 4 26 1 11 1 25 R 1 10 1 32 24 2 9 2 23 2 8 4 22 8 7 1 21 2 6 2 20 2 5 1 19 2 4 1 18 O 4 3 1 17 O 4 2 1 16 4 1 1 15
Refer to Accessories (page 28). Fieldbus interface connector layout BUS OUT: M12 5-pin socket, A-coded (SPEEDCON) No. Designation Description 1 SLD Shield 2 DB Communication wire DB 3 DG Communication wire DG 4 DA Communication wire DA 5 Unused : Recommended mating M12 4-pin plug, part no. PCA-1567717. (Refer to page 28) BUS IN: M12 4-pin plug, A-coded (SPEEDCON) No.
D-M9NW D-M9NWV D-M9PW D-M9PWV D-M9BW D-M9BWV Wiring 3-wire 2-wire Output NPN PNP Lead wire orientation In line Perpendicular In line Perpendicular In line Perpendicular Applicable load IC circuit/Relay/PLC 24 VDC Relay/PLC Power supply voltage 5/12/24 VDC (4.5 to 28 VDC) Current consumption 10 mA or less Load voltage 28 VDC or less 24 VDC (10 to 28 VDC) Load current 40 mA or less 2.5 to 40
(Refer to page 28) 2. Re Register The structure memory information of the unit is updated. (Refer to page 29) 3. Hold/Clear This mode is used to select whether the Hold/Clear function is set by the switch on the SI unit or by the Handheld Terminal. (Refer to page 30) 4. Clr Counter Value The ON/OFF counter value of each unit is cleared. (Refer to page 31) 5.
PFMC7--CNPN (1 output) + Analogue (4 to 20 mA) output type PFMC7--DMaximum applied voltage: 28 V Maximum load current: 80 mA Internal voltage drop: 1 V or less C: Analogue output: 1 to 5 V Output impedance: 1 k D: Analogue output: 4 to 20 mA Maximum load impedance: 600 Minimum load impedance: 50 NPN (1 output) + External input type PFMC7--GMaximum applied voltage: 28 V Maximum load current
with double knuckle joint. +0.058 0 +0.058 0 +0.070 0 +0.084 0 +0.084 0 0.10 0.30 0.10 0.30 0.10 0.30 0.10 0.30 0.10 0.30 14 19 24 26 26 20 22 28 40 40 30 40 50 60 60 M10 x 1.25 16 19 24 34 34 M10 x 1.25 10 11 14 20 20 16 19 24 34 34 40 50 64 80 80 10 10 14 22 22 14 14 20 30 30 28 28 40 60 60 10 10 14 22 22 14 14 20 30 30 12 M14 x 1.5 M14 x 1.5 12.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 M18 x 1.5
finish Ra max 10 in. (0.25 m) Standard 7 in. (0.18 m) 5 in. (0.13 m) Code 0 M V X Specification Standard Sub-atmospheric Code V3 L 1 H 2 4 10 40 -30 in.Hg to 30 psig -30 in.Hg to 60 psig -30 in.Hg to 100 psig -30 in.Hg to 160 psig 0 to 200 psig 0 to 400 psig 0 to 1000 psig 0 to 4000 psig -0.1 to 0.2 MPa -0.1 to 0.4 MPa -0.1 to 0.7 MPa -0.1 to 1.1 MPa 0 to 1.4 MPa 0 to 3 MPa 0 to 7 MPa 0 to 28
CDQSK Bore size Bore size SCQS , #7 (#7+#11) 2.2-28 Compact Cylinder/Non-rotating Rod: Double Acting Single Rod Series CQSK Foot (All dimensions are common between standard stroke and long stroke except "A", "B" and "LS".)
8 42 With filter (80 mesh) Series SYJA700 Base mounted: SYJA74-01 02 Body ported: SYJA72-01 (-F) 2-3.2 25 25.5 (For manifold mounting) 12 1.5 13 A 18 1 23.5 11 M5 x 0.8 48.7 (Bracket) (Pilot port) (Pilot port) 2-3.2 M5 x 0.8 (For mounting) 2-4.5 Manual override (Non-locking) Manual override (Non-locking) (External pilot port) (For mounting) (For solenoid valve) 12 23.5 11 A (44) (36) 21 28
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 34.5 (For AC) 3-M3 x 0.5 (Piping port) 28 (For DC) + G: 300 H: 600 (Lead wire length) P 15.6 11.5 12 6 2.8 9 A R 3 1.5 1 19.5 L plug connector (L): SY1 3(A)-L-PM3(F) 1 2 M plug connector (M): SY1 3(A)-M-PM3(-F) 1 2 + (Light/Surge voltage suppressor
1/43/8 1/8 38.4 AW40K-B 70 147.1 91.7 37.3 80 37.3 1.5 28 42.5 75.7 42.5 1/43/81/2 1/8 1/8 44.3 38.4 80.8 75.7 AW40K-06-B 75 149.1 93.2 37.3 80 37.3 1.2 28 42.5 75.7 42.5 3/4 AW60K-B 95 234.1 175.5 47.5 30 47.5 3.2 28 42.5 80.8 42.5 1 1/8 Optional Bracket mount dimensions Panel mount dimensions Model Q S T U AW20K-B 30 34 43.9 5.4 15.4 55 2.3 24.7 28.5 14 6 AW30K-B 41 40 45.8 6.5 8 53
(Red Green Red) PLC: Programmable Logic Controller D-P4DWL/Z (With indicator light) D-P4DWL D-P4DWZ Auto switch model 24 VDC relay, PLC Applicable load 24 VDC (20 to 28 VDC) Load voltage 6 to 40 mA or less Load current 5 V or less Internal voltage drop 1 mA or less at 24 VDC Leakage current 40 ms or less Operating time Operating position . Red LED illuminates.
Barb one-touch Reducer 3.2, 4 Port size 3 5 32 04 M3 x 0.5 M5 x 0.8 3.2 4 15-6-28 5 Miniature Fittings Series M Barb fitting: M-3AU-2, M-5AU-2 Applicable tubing O.D. x I.D.
40 28 40 33 50 33 50 0.7 0.5 1 2 VC 3 4 1.0 0.8 VDW 1.4 1.2 1 VQ 1 4 1 2.4 2.2 VX2 5.2 5.0 32 VX Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1 2 1 3.8 3.6 VX3 7.0 6.8 40 JIS Symbol Valve type Operation N.C.