SMC Corporation of America
Elite Part Number Search
Search Results "VEX3500-10-B"

Body Size: 60, Back Flow: w/o Backflow, Thread: Rc, Port Size: 1, Options: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: Metal Bowl, Bowl Guard: None, Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving Type, Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Units: Product: MPa, °C; Pressure Gauge: MPa, Made to Order: -

Body Size: 60, Back Flow: w/Backflow, Thread: Rc, Port Size: 1, Options: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: Metal Bowl w/Level Gauge, Bowl Guard: None, Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving Type, Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Units: Product: MPa, °C; Pressure Gauge: MPa, Made to Order

Body Size: 60, Back Flow: w/o Backflow, Thread: Rc, Port Size: 1, Options: w/o Mounting Option, Set Pressure: 0.02 to 0.2 MPa Setting, Bowl: Metal Bowl w/Level Gauge, Bowl Guard: None, Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving Type, Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Units: Product: MPa, °C; Pressure Gauge: MPa, Made to Order

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.14 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.14 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Air cushion, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches:

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, Cushion: Rubber cushion, Operating Pressure(MPa): 0.08 to 0.7, Specification: Built-in magnet, Auto Switches: Without