This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
SMC's VP300/500/700 series solenoid valve, offers high flow capacity and reduced power consumption (1.55W standard, 0.55W with power saving circuit). The VP series may be used as either a selector valve, or a divider valve. It is available in a normally closed or a normally open style. The series is vacuum applicable up to –101.2kPa. 3 PORT SOLENOID VALVE. VP valve manifold. 1850.00000
SMC's VP300/500/700 series solenoid valve, offers high flow capacity and reduced power consumption (1.55W standard, 0.55W with power saving circuit). The VP series may be used as either a selector valve, or a divider valve. It is available in a normally closed or a normally open style. The series is vacuum applicable up to –101.2kPa. 3 PORT SOLENOID VALVE. VP valve manifold. 2070.00000
SMC's VP300/500/700 series solenoid valve, offers high flow capacity and reduced power consumption (1.55W standard, 0.55W with power saving circuit). The VP series may be used as either a selector valve, or a divider valve. It is available in a normally closed or a normally open style. The series is vacuum applicable up to –101.2kPa., VP valve manifold, 3 PORT SOLENOID VALVE
SMC's VP300/500/700 series solenoid valve, offers high flow capacity and reduced power consumption (1.55W standard, 0.55W with power saving circuit). The VP series may be used as either a selector valve, or a divider valve. It is available in a normally closed or a normally open style. The series is vacuum applicable up to –101.2kPa., VP valve manifold, 3 PORT SOLENOID VALVE, 1080 lb
SMC's VP300/500/700 series solenoid valve, offers high flow capacity and reduced power consumption (1.55W standard, 0.55W with power saving circuit). The VP series may be used as either a selector valve, or a divider valve. It is available in a normally closed or a normally open style. The series is vacuum applicable up to –101.2kPa., VP valve manifold, 3 PORT SOLENOID VALVE, 2290 lb
SMC's VP300/500/700 series solenoid valve, offers high flow capacity and reduced power consumption (1.55W standard, 0.55W with power saving circuit). The VP series may be used as either a selector valve, or a divider valve. It is available in a normally closed or a normally open style. The series is vacuum applicable up to –101.2kPa., VP valve manifold, 3 PORT SOLENOID VALVE, J31,
SMC's VP300/500/700 series solenoid valve, offers high flow capacity and reduced power consumption (1.55W standard, 0.55W with power saving circuit). The VP series may be used as either a selector valve, or a divider valve. It is available in a normally closed or a normally open style. The series is vacuum applicable up to –101.2kPa., VP valve manifold, 3 PORT SOLENOID VALVE, J31,
SMC's VP300/500/700 series solenoid valve, offers high flow capacity and reduced power consumption (1.55W standard, 0.55W with power saving circuit). The VP series may be used as either a selector valve, or a divider valve. It is available in a normally closed or a normally open style. The series is vacuum applicable up to –101.2kPa., MANIFOLD ASS'Y, 3 PORT SOLENOID VALVE, J31, 750
SMC's VP300/500/700 series solenoid valve, offers high flow capacity and reduced power consumption (1.55W standard, 0.55W with power saving circuit). The VP series may be used as either a selector valve, or a divider valve. It is available in a normally closed or a normally open style. The series is vacuum applicable up to –101.2kPa., VP valve manifold, 3 PORT SOLENOID VALVE, J31,
SMC's VP300/500/700 series solenoid valve, offers high flow capacity and reduced power consumption (1.55W standard, 0.55W with power saving circuit). The VP series may be used as either a selector valve, or a divider valve. It is available in a normally closed or a normally open style. The series is vacuum applicable up to –101.2kPa., VP valve manifold, 3 PORT SOLENOID VALVE, J31,
SMC's VP300/500/700 series solenoid valve, offers high flow capacity and reduced power consumption (1.55W standard, 0.55W with power saving circuit). The VP series may be used as either a selector valve, or a divider valve. It is available in a normally closed or a normally open style. The series is vacuum applicable up to –101.2kPa., MANIFOLD, 15-STA., 3 PORT SOLENOID VALVE, J31,
Type: 41 (Feedback Sensor Type), Bar Length: 580mm, Electrode Cartridge, Needle Material: High Speed De-Ionizing Cartridge, Tungsten, Input/Output Specifications: NPN (or N/A for Type 40), Power Supply Cable: Z (10m), One-Touch Fitting: ø8, Bracket: B (Bracket), Sensor: F (Feedback Sensor for Type 41)
Type: 41 (Feedback Sensor Type), Bar Length: 1720mm, Electrode Cartridge, Needle Material: High Speed De-Ionizing Cartridge, Tungsten, Input/Output Specifications: P (PNP), Power Supply Cable: 3m, One-Touch Fitting: ø10, Bracket: B (Bracket), Sensor: Type 40: N/A; Type 41 & 42: Built-in Auto Balance Sensor, Option: X10 [Non-standard Bar Length (Not Required with Electrode Cartridge Drop Prevention
03-10W2 AS321F-03-12W2 AS421F-04-10W2 AS421F-04-12W2 11.6 6 9 13.5 22.9 11.7 28.8 26 25.2 22.4 18.1 8 6 9.6 M5 x 0.8 13.2 6 19 17 31 23.9 13.4 15.2 R 1/8 8 21 18.5 32.4 36.4 31.4 33.3 28.3 25.3 12 10 14.2 18.5 10 23 21 39.2 15.2 32.1 13.2 6 34 17 34.4 25.2 17.7 15.2 17 8 36 12 18.5 36.4 41.1 36.1 35.6 30.6 27.2 18.5 18.5 10 38 21 18.3 44.5 35.3 13.2 6 R 1/4 63 17 39.3 27.8 15.2 8 65 18.5 41
AS3002F-10 AS3002F-12 AS4002F-10 AS4002F-12 D2 D3 D4 L1 L2 L3 L5 L6 L7 L8 M1 MIN. 18.4 21 21.7 22.7 25.4 26.5 28.2 29.5 33.6 34.4 36 37.1 44.1 45.1 3.2 5 6 25.4 36 37 39.5 40.7 42.5 53.2 57.2 59 65 70.8 76 76.9 81.3 3.4 4.4 5.1 6.1 5.2 6.3 6.7 8 7.4 8.2 9.8 10.9 10.3 11.3 7.9 11.1 11.8 12.8 12.3 13.4 16.3 17.6 19.3 20.1 21.7 22.8 22.7 23.7 20.9 23.8 24.5 25.5 28.9 30 33.2 34.5 38.6 39.4 41
Nil M5 x 0.8 Rc1/8 Rc1/8 Rc1/8 Rc1/4 TN NPT1/8 NPT1/8 NPT1/8 NPT1/4 TF G1/8 G1/8 G1/8 G1/4 12-CY3B15 12-CY3B20 12-CY3B25 12-CY3B32 12-CY3B40 d b C H B H 4 8 8 10 d M10 x 1.0 M20 x 1.5 M26 x 1.5 M32 x 2.0 B 14 26 32 41 C 16.2 30 37 47.3 Part number SNJ-016B SN-020B SN-032B SN-040B Applicable bore size (mm) 15 20 25, 32 40 161 Specific Product Precautions Be sure to read before handling.
F (C) Correction factor 1.41 41 to 86 (5 to 30) Air ow capacity scfm (m3/min) (ANR) 50 Hz 565 (16) 709.8 (20.1) 882.8 (25) 50 (10) 1 1.21 95 (35) 60 Hz 663.8 (18.8) 836.9 (23.7) 953.4 (27) 59 (15) 1.4 1 104 (40) 61 (16) or more 1.5 0.92 113 (45) The maximum coefficient value is 1.5 due to the drainage separation performance. 0.75 122 (50) 0.63 131 (55) Data D: Inlet Air Pressure 0.53 140
Bore (mm) -Stroke (mm) 5~50, 75, 100, 125, 150 63-50, 75, 100, 125, 150 1 4~50, 75, 100, 125, 150, Additional symbol B-With limit switch mounting bracket D-With cam K-With special bracket N-Different rod end length Rod attachment No mark-No attachment I-Single knuckle jOint Y-Double knuckle joint 41) Construction/Parts List.