3 Port Solenoid Valve Series VV100/D-sub Connector Plug-in Connector Type Manifold How to Order Manifold U 1 VV100 10F C6 05 D A 2 D-sub connector type Mounting option Symbol A B Number of poles Symbol Mounting Connector block mounting position: D side 15 26 Manifold direct mounting type Nil Connector entry direction Upward Valve stations A: D-sub connector 15 pins With mounting nut M3 x
How to Order Symbol 2 1 01 06 2 AS 1 F E S K JIS Symbol Hexagonal lock nut Body size 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard With seal Applicable tubing O.D.
Type: -, Connection Method: -, Compressed Air Quality: General Dry Air, Connection Type: [NPT] NPT, Plumbing Thread Nominal: 1/4, Filtration Level: 0.3μm, Operating Environment: Standard, Operating Pressure Range(MPa): -, Flow Direction: [Left] Right→Left, Drain Cock: -, Bowl Material: [Resin] Polycarbonate Case, Bowl Guard: No, Size of Body: 20, Accessory: None, O-Ring, Gasket Material:
Type: -, Connection Method: -, Compressed Air Quality: General Dry Air, Connection Type: [NPT] NPT, Plumbing Thread Nominal: 1/4, Filtration Level: 0.3μm, Operating Environment: Standard, Operating Pressure Range(MPa): -, Flow Direction: [Right] From Left to Right, Drain Cock: [Auto Float Type] N.C. Automatic Drain, Bowl Material: [Resin] Polycarbonate Case, Bowl Guard: No, Size of Body:
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: C (N.C., Float Type Auto Drain), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F), Made to Order: X2141 (w/Element Service Indicator)
Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: C (N.C., Float Type Auto Drain), Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F), Made to Order: X2141 (w/Element Service Indicator)
Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: R (Flow Direction Right to Left), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F), Made to Order: X2141 (w/Element Service Indicator)
Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F), Made to Order: X2141 (w/Element Service Indicator)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: C (N.C., Float Type Auto Drain), Semi-Standard 1: R (Flow Direction Right to Left), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F), Made to Order: X2141 (w/Element Service Indicator)
Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: C (N.C., Float Type Auto Drain), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F), Made to Order: X2141 (w/Element Service Indicator)
Body Size: 20, Thread: NPT, Port Size: 1/8, Option: N.C., Float Type Auto Drain, Semi-Standard 1: Standard, Semi-Standard 2: Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F, Made to Order: w/Element Service Indicator
Body Size: 20, Thread: NPT, Port Size: 1/4, Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: Standard, Semi-Standard 2: Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F, Made to Order: w/Element Service Indicator
Body Size: 20, Thread: NPT, Port Size: 1/8, Option: N.C., Float Type Auto Drain, Semi-Standard 1: Flow Direction Right to Left, Semi-Standard 2: Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F, Made to Order: w/Element Service Indicator
Body Size: 20, Thread: NPT, Port Size: 1/4, Option: N.C., Float Type Auto Drain, Semi-Standard 1: Bowl Guard, Semi-Standard 2: Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F, Made to Order: w/Element Service Indicator
5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS1000 How to Order 01 VFS1 1 20 1 G Symbol Option 2 position single F: With foot bracket Thread type 1 Nil N Rc NPT NPTF G T Port size 01 F Rc 1 8 2 position double SJ Option 2 Mountable only for VFS1120.
Model Pressure range *1 Indication unit Connection thread Note MPa Port size 01 Rc1/8 02 Rc1/4 R1/8 R1/4 G46-7-02-SRB 0 to 0.7 R1/4 G46-10-02-SRB 0 to 1.0 G46-4-01 to 02-SRB 0 to 0.4 MPa Set pressure range: 0.05 to 0.69 MPa 02 WR110 X215 *1: Do not apply more pressure than the max. pressure displayed. It may cause a malfunction.
Body size Port size KKA3 S-01 M KKA3 P-01 M R1 / 8 R1 / 8 1 / 8 KKA3 S-02M 1 / 8 KKA3 P-02M R1 / 4 R1 / 4 KKA3 S-03 M KKA3 P-03 M R3 / 8 R3 / 8 KKA4 S-02M KKA4 P-02M R1 / 4 R1 / 4 KKA4 S-03 M 1 / 4 KKA4 P-03 M 1 / 4 R3 / 8 R3 / 8 KKA4 S-04 M KKA4 P-04 M R1 / 2 R1 / 2 KKA6S-03 M KKA6P-03 M R3 / 8 R3 / 8 KKA6S-04 M KKA6P-04 M 1 / 2 1 / 2 R1 / 2 R1 / 2 KKA6S-06M KKA6P-06M R3 / 4 R3 / 4 Built-in
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: 01 (Rc1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: V (Panel Mount Adapter for w/
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: 01 (Rc1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: V (Panel Mount Adapter for w