Standard Strokes Bore size [mm] Standard stroke [mm] Max. manufacturable stroke 32 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 45 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 56 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 63 25, 50, 75, 100, 125, 150
Copper extension nozzle/KNL (mm) Model Nozzle size D Outside diameter L1 Weight (g) KNL3-06-150 KNL3-06-200 KNL3-08-200 KNL3-08-250 KNL3-10-250 KNL3-10-300 KNL6-06-150 KNL6-06-200 KNL6-08-200 KNL6-08-250 KNL6-10-250 KNL6-10-300 1.5 2 2 2.5 2.5 3 1.5 2 2 2.5 2.5 3 6 6 8 8 10 10 6 6 8 8 10 10 300 300 300 300 300 300 600 600 600 600 600 600 43 43 61 61 94 94 84 84 117 117 183 183 O.D.
Port size For sub-plate, manifold type 40, 41, 42, 43 Nil: Without sub-plate R port P, E port 3: Common exhaust type for main and pilot valve D: Push-turn locking slotted type R port P, E port (With gasket and screws) 01: 1/8 With sub-plate Electrical entry 24, 12, 6, 5, 3 VDC M8 connector 24, 12, 6, 5, 3 VDC 100,110, 200, 220 VAC 24,12 VDC 100,110, 200, 220 VAC Grommet L plug connector M
, 250, 300, 350, 400, 450, 500, 600, 700, 800 25 4000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 32 5000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 40 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 6000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 63 Note1) Contact P/A in case of a stroke length beyond the maximum.
5 Port Solenoid Valve Series VQC Lateral Plug-In Manifold Style Wide Range of Electrical Entries Manifold Options Conforming to 1P67 NEW CONCEPT Connector Type Manifold Series VQC1000/2000/4000 Outstanding response times and long life Conforming to IP67 for protection from dust and moisture (Metal seal: Single type with light and surge suppressor) VQC1100: 10ms 2ms; 200 million cycles VQC2100
Configuration Minimum equipment and wiring requirements to get started 1 Provided by customer Ex) 200 V AC (*1) 7 Provided 6 1 by customer 8 2 3 N PC 1 2 5 9 C D 11 21 10 4 (*2) U 2 Electric Actuators Ex) LEF V W Provided by customer 3 PLC (CC-Link master unit) 11 (*1) Refer to LECSC Operation Manual, Chapter 4 for further details if the power supply voltage is 100VAC. (*2) When wiring to
Cylinder Speed Chart Bore size Series CS1/CS2 Pressure 0.5 MPa, Load factor 50% Cylinder stroke 300 mm Average velocity (mm/s) System 125 140 160 180 200 250 300 1000 Vertically upward movement Horizontal movement 900 800 700 600 500 400 300 200 100 0 A 800 900 1000 700 600 500 400 300 200 100 0 B 900 1000 800 700 600 500 400 300 200 100 0 C 800 900 1000 700 600 500 400 300 200 100 0 D 800
Next, the viscosity of 15 mPas and the discharge rate of 200 l/min in the required specification example are converted to the discharge rate for fresh water. Since 48% of the fresh water discharge rate is equivalent to 200 ml/min in the required specifications, 200 ml/min 0.48 = approximately 420 ml/min, indicating that a discharge rate of 420 ml/min is required for fresh water. 3.
CAT.ES11-80 A 5-Port Solenoid Valve Series VQC NEW CONCEPT Connector Type Manifold Series VQC1000/2000/4000 Outstanding response times and long life Conforming to IP67 for protection from dust and moisture (Metal seal: Single type with light and surge suppressor) VQC1100: 10ms 2ms; 200 million cycles VQC2100: 20ms 2ms; 200 million cycles VQC4100: 17ms 3ms; 100 million cycles (Based on IEC529
" SO, "63 a.5 25, 50, 75, 100,125, 150, 175, 200, 250.300, 350. 400. 450, 500 40 " !
RS Q G RS H A Relation of Liquid Entry and Sliding Distance Amount of liquid entry (g) x 15 RZQ 10 Standard cylinder MI W S Stainless steel cylinder 5 CEP1 0 50 100 150 200 Sliding distance (km) 250 300 CE1 Conditions Working fluid Air Pressure 0.5 MPa Liquid Water-soluble coolant Piston speed 200 mm/sec (60 cpm) CE2 ML2B Special scraper C J G5-S Exterior configuration reduces residual
M5 x 0.8 12-CY3B10 10 500 50, 100, 150, 200, 250, 300 12-CY3B15 15 1000 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 12-CY3B20 20 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Rc1/8 NPT1/8 G1/8 12-CY3B25 25 (Both sides) Non-lube 12-CY3B32 32 1300 Rc1/4 NPT1/4 G1/4 12-CY3B40 40 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 12-CY3B50 50 12-CY3B63 63
RS Q G RS H A Relation of Liquid Entry and Sliding Distance Amount of liquid entry (g) x 15 RZQ 10 Standard cylinder MI W S Stainless steel cylinder 5 CEP1 0 50 100 150 200 Sliding distance (km) 250 300 CE1 Conditions Working fluid Air Pressure 0.5 MPa Liquid Water-soluble coolant Piston speed 200 mm/sec (60 cpm) CE2 ML2B Special scraper C J G5-S Exterior configuration reduces residual
Cylinder stroke [mm] Bore size Standard stroke [mm] 12 (10 x 2) 16 (12 x 2) 10, 20, 30, 50, 100 20 (16 x 2) 25 (20 x 2) 20, 30, 50, 100, 150 Port thread type Nil M thread 12 to 32 Rc 32 (25 x 2) 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) 80 (56 x 2) 100 (71 x 2) 40 to 100 TN NPT TF G 25, 50, 100, 150, 200 Refer to page 4 for intermediate strokes.
Current consumption 55 mA or less Protection Polarity protection Power supply voltage for sensor 1 Power supply voltage: 1.5 V Power supply current for sensor 2 Max.110 mA (However, the total power supply current of 4 input is 440 mA or less maximum) The total power supply current when used as an IO-Link device is 200 mA or less maximum Display accuracy (Linearity) 5.0%F.S.
Rated Rated Sensitivity voltage x size voltage current of leak [V] [A] current [mA] HRS012--10 HRS018--10 1-phase 100V AC(50Hz) 100 200 15 15 or 30 HRS01--10-T 1-phase 3 cores x Sharing 100V to 115V 14AWG (High pump head AC(60Hz) [Optional]) (3 cores x 2.0mm2) HRS012--20 HRS018--20 HRS024--20 1-phase 10 30 (including ground) 200, 200-230V AC 230 HRS0--20-T (50/60Hz) 15 30 (High pump head
Basic setting mode Main menu Alarm display menu Maintenance notif Power supply ON Circulating fluid outlet temperature Circulating fluid set temperature 200 ALm mANT 200 XXALM MENU MENU MENU / / / M no (N M circulating fluid return temp AL01 mT01 212 Alarm number (Alarm number minimum RET TEMP / / / M n mT02 AL02 014 Alarm number Circulating fluid outlet pressure PRESS / 79 Circulating fluid
Surface finish Ra max 10 in. (0.25 m) Standard 7 in. (0.18 m) 5 in. (0.13 m) Code 0 M V X Specification Standard Sub-atmospheric Code V3 L 1 H 2 4 10 40 -30 in.Hg to 30 psig -30 in.Hg to 60 psig -30 in.Hg to 100 psig -30 in.Hg to 160 psig 0 to 200 psig 0 to 400 psig 0 to 1000 psig 0 to 4000 psig -0.1 to 0.2 MPa -0.1 to 0.4 MPa -0.1 to 0.7 MPa -0.1 to 1.1 MPa 0 to 1.4 MPa 0 to 3 MPa 0 to 7
Q[l/min(ANR)] = X X 60 X C X D2 X W 4 X 106 (P2 + 0.101) 0.101 Q[l/min(ANR)] = X X 60 X 1 = 841 X 1002 X 200 4 X 106 (0.8 + 0.101) 0.101 Refer to p.1.13-2 for flow rate characteristics table. Select booster regulator size from flow characteristic stable.
Male thread Suitable screw torque (Nm) Hexagonal width (mm) Adjustable spanner nominal (mm) 1/4 4.5 M3 M5 10/32-UNF 100 1/6 8 150 7 to 9 14 1/8 200 12 to 14 17 1/4 200 22 to 24 21 3/8 200 28 to 30 24 1/2 1Nm=10.2kgf/cm Tightening torque for lock nuts Caution qSuitable screw torque for a hexagon lock nut is shown in the table below.