CN2 11 15 14 2 12 PF SG CR PP PG NP NG SD V24 SON LSN LSP ALM SG 3 12 13 9 10 7 8 20 17 11 LG 19 P5 4 OP 1 V+ 20 12 7 6 P5 LG MR MRR MD MDR SD SG 7 8 1 2 4 5 9 P5 LG MR MRR MD MDR SHD 7 8 1 2 4 9 P5 LG MR MRR MD MDR SHD Note 3) Detector 17 16 Plate 5 Note 2) Note 6) Be sure to connect the shielding wires to the ground plate inside the connector.
Heat treatment 1 Stainless steel Body Heat treatment 2 Stainless steel Table 7 1 2 8 9 6 13 12 11 3 Resin Cover 4 Resin Return guide 5 Scraper Electroless nickel plated 6 Brass Piston Electroless nickel plated 7 Carbon steel Joint shaft Electroless nickel plated 8 Brass End cap 9 Polyurethane Rod bumper 10 Steel ball High carbon chrome bearing steel Electroless nickel plated 11 Plug Brass
View A Terminal block number 4 3 2 1 1 2 3 4 5 6 7 8 8 7 6 5 Series PF2D For Deionized Water and Chemicals Digital Flow Switch Functions/PF2D Refer to the operation manual how to set and to operate. Output types Flow rate measurement selection Real-time flow rate and accumulated flow rate can be selected.
View A PFA3-B DIN rail type Sensor Blue Brown Black Analog output 1 2 3 4 3 x 7.2 (= 21.6) 8-M3 36 15 6.4 2 3.4 5 6 7 8 OUT1 N.C. Load Load 2 1 3 4 6.5 12 to 24VDC + 26 SMC FLOW SWITCH PFA312-(-M) 35.5 30 15.2 56 (4.5) 44 UNIT RESET SET Sensor Blue Brown Black Analog output 1 2 3 4 5 6 7 8 5 6 7 8 29 OUT1 N.C.
D. 7 to 9:P368010-26 Applicable cable O.
I.D. 40.9 40.3 27.6 27 15.5 15.2 1.5 1.6 13 17 23 22 KFH04-00 KFH06-00 KFH08U-00 KFH08N-00 KFH10U-00 KFH10N-00 KFH12U-00 KFH12N-00 2.5 4 5 6 6.5 7.5 8 9 4 6 8 10 10 12 6 11 17 21 30 35 45 3 4 5 5.5 6.5 7 8 8 16.2 41.3 28 12 14 36 10 18.8 17 17 44.6 30 42 41 12 19.3 17 19 45.5 32 Male elbow: KFL Applicable tube (mm) Thread R(PT) Part No. H1 (Hex.) H2 (Hex.)
Prefix it to the part nos. of the solenoid valve, etc. 7 Series SYJ300 Combinations of Solenoid Valve, Manifold Gasket and Manifold Base Blanking Plate Assembly Body ported (Type SYJ32(R)) Base mounted (Type SYJ34(R)) Model no.: SYJ300-10-1A Model no.: SYJ300-10-2A Round head combination screw SY100-33-2 (M1.7 x 7, Matt nickel plated) Blanking plate SYJ300-10-1 Round head combination screw
Terms Meaning 7 Display type where each individual display character consists of up to 7 separate sections (called segments) (The figure 8 uses all 7 segments) 7-segment indication A Adsorption directive signal Indicate the command signal which generate vacuum.
ON (/ /) ON 1 OFF OFF DC(+) DC(-) 2 ON DC(+) DC(-) NPN PNP ( ) 3 OFF ( ) () DC(+) DC(-) () 4 -68No.PS-OMU0002CN-D No. () 5 (A/D ) ( ) 6 1015 10 -69No.PS-OMU0002CN-D No. 80 mA (Er1,2) () (Er1,2) ( ) (Er0,4,6,7,8,9) DC1224 V (Er0,4,6,7,8,9) 10% DC1224 V10 (Er13) No.18 7 (Er13) HHH (HHH) LLL (Er3) (LLL) (Er3) 7 F.S.(3.5F.S.) -70No.PS-OMU0002CN-D No.
(Er1,2) () ( ) (Er1,2) (Er0,4,6,7,8,9) DC1230 V DC1230 V (Er0,4,6,7,8,9 ) 6 "HHH" (HHH) "LLL" (Er3) (LLL) (Er3) 7 F.S.(3.5F.S.) DC1230 V DC1230 V DC(+) DC(-) 7 -76No.PS-OMV0003CN-G No.
(Er1,2) () ( ) (Er1,2) (Er0,4,6,7,8,9) DC1230 V DC1230 V (Er0,4,6,7,8,9) 6 HHH (HHH) LLL (Er3) (LLL) (Er3) 7 F.S.(3.5F.S.) DC1230 V DC1230 V DC(+) DC(-) 7 -80No.PS-OMV0008CN-E No.
"8"7 "-"()7 digit() 1digit=1kPa 1,2,3,,99,100 1kPa 1~5[V] F.S.=514[V] 1F.S.40.010.04[V] F.S. ( NPN()() NPN PNP()() PNP TSJ Tube Swage Joint Swagelok swagelok URJ Union Ring Joint Swagelok VCR ON OFF () (26 ) ON OFF Hysteresis ON-OFF / () () 25[]ON-OFF -11No.PS-OMM0002CN-F NPN () () ()()( ) () ON ON 0 (1k 1M A/D 5V A/D 5(V)1(M)/(1(k)+1(M))4.995(V)0.005V ) 26 ON-OFF ON (
Series VX Solenoid Coil Assembly How to Order VX021 C 001 01 B Rated voltage (1) VX solenoid coil assembly 02 =+4 7> 01 =+4 7> Electrical option Application 03 =+4 7> Nil # 04 =+4 7> > -/& S 5 % * ,* -05 ( ! 001 # ) # ) #' ) L 5 % ) / *% 06 ! ' 002 003 Z 5 % *%+ * ,* -07 ( =+4 7> 08 (?
Port size VCB2 VCW20-12-01A 34 40 25 30 12.8 12.8 5 4.5 6 13 1/8, 1/4 VCW30-12-02A 42 52 30 40 19 19 6 5.5 7 19 1/4, 3/8 VCB3 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-02A 42 52 30 40 23 23 6 5.5 7 19 1/4, 3/8 VCB4 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-06A 56 65 44 53 28.2 28.2 6 5.5 7 26 3/4 2 mounting screws (for mounting bracket) are included
B: Locking slotted type 4 1 6A 8A 10A 10A 15A 20A 25A 32A 40A 50A 1 8 1 4 3 8 3 8 1 2 3 4 220 VAC 50/60 Hz 10 5 6 24 VDC 12 VDC 240 VAC 50/60 Hz 7 15 2 9 Other Nil: Non-locking push type 20 3 Option Valve size 5 to 7 25 4 1 1 1 2 32 5 1 4 1 2 40 50 6 7 Note) Air operated only Electrical entry/ With light/surge voltage suppressor E GS G Grommet with surge voltage suppressor Grommet Grommet
14.7 19.5 3.8 Deep style (D) ZP10Dl to 40Dl Model Nom.size U02 A 2 B 2.6 C 1.2 D 7 E F 12 Y 0.8 _ _ _ _ ZP02Ul ZP04Ul ZP06Ul ZP08Ul ZP10Ul ZP13Ul ZP16Ul ZP20Ul ZP25Ul ZP32Ul ZP40Ul ZP50Ul U04 4 4.8 1.6 7 12 0.8 U06 6 7 2.5 7 12 0.8 U08 8 9 2.5 7 12 1 U10 10 12 4 13 7.7 12 3 U13 13 15 4 13 7.7 12 3 U16 16 18 4 13 8.2 12.5 3.5 U20 20 23 4 15 9.5 14 4 U25 25 28 4 15 9.5 14 4 U32 32 35 4 15
monilor oulplt 4 18 Nol avariable with pressure range 19 " 40" input output combination not avaibbte CE maked 0.1s qk =7{< <.k_"
Minimal flow rate variations between knob rotations Contact face stopper Fully closed Mounting Variations DIN rail mounting bracket Direct mounting Holder mounting DIN rail mounting If the mounting surface does not interfere with the bonnet: If the mounting surface interferes with the bonnet: Page 7 Page 7 Adapter needed Page 10 Bonnet Bonnet Bonnet Page 7 Holder for speed controller Mounting
CJ2Y-Z CM2Y-Z CG1Y-Z MBY-Z CA2Y-Z CS2Y CQSY CQ2Y-Z CJ2X-Z CM2X-Z CQSX CQ2X CUX (mm) Auto switch model Bore size 10 16 Auto switch mounting Auto switch model Bore size (mm) 10 16 D-M9m/M9mV D-M9mW/M9mWV D-M9mA/M9mAV 2.5 3 D-M9m D-M9mV D-M9mW D-M9mWV D-A9m D-A9mV Band mounting BJ6-010 (A set of a, b, c, d) BJ6-016 (A set of a, b, c, d) D-A9m 6 7 D-C7m/C80/C73C/C80C 7 7 D-H7m/H7mW D-H7BA/H7NF