SMC Corporation of America
Elite Part Number Search
Search Results "VM830-01-13"

Communication connector D-sub 9 pin (socket) Holding screw: M2.6 6 Contact a for output cutoff alarm (open when alarm occurs) 7 Common for output cutoff alarm 9 15 10 11 12 13 14 Pin no.

.: 0.4 [10 mm], Length: 31.5 [0.8 m]) H 4 x 0.5 [4 x 13 mm] N M L K Power cable with plug (Length: 110 [2.8m]) Dimensions Unit: inch [mm] A B C D E F G H J K L M N Q Model Port size 17.8 [453] IDFB4E 1/2 19.6 [498] 11.1 [283] 10.8 [275] 17.9 [455] IDFB6E 0.5 [13] 10.6 [270] 1.2 [31] 1.7 [42] 3.1 [80] 9.1 [230] 1.3 [32] 0.6 [15] 9.4 [240] 3.1 [80] IDFB8E 3/4 22.4 [568] 14 [355] 11.8 [300]

Applicable bore size A D L MM N R W Flat type Round type CJ-CF010 CJ-CR010 10 8 10 13 M4 x 0.7 6 10 8 Part no.

36.5 9.5 M8 x 1.25 11 8 30 32 63.5 15 55 13 36.5 15 M8 x 1.25 13 8 30 32 63.5 Metal cover type Leave sufficient space to open and close the metal cover when operating the manual release.

-CY3B32 12-CY3B40 12-CY3B50 12-CY3B63 R 12 15 18 23 27.5 34.5 6.5 7.5 8 10 10 13 13 M3 x 0.5 M6 x 1 M3 x 0.5 M10 x 1 M4 x 0.7 M10 x 1 M4 x 0.7 M20 x 1.5 M5 x 0.8 M26 x 1.5 M6 x 1 M26 x 1.5 M6 x 1 M32 x 2 0.007 0.037 M8 x 1.25 M8 x 1.25 M8 x 1.25 M10 x 1.5 P (Piping port) W X Y ZZ Model Mounting Nut/Included in the package (2 pcs).

DGraph (2) Cylinder Output on the Retracting Side (Double acting) 20150 1500 Tube bore size [mm] 100 1000 40 Side load Balance weight 40 50 400 500 32 20 25 30 200 250 300 Operating pressure [MPa] Cylinder output F[N] Load weight [kg] 15 150 Allowable Side Load on the Piston End (Nm) 10 100 Stroke of linear part Size 40 5 10 15 20 25 30 40 50 75 100 4 5 40 50 32 40 14 14 13 13 13 12 12 11

MSQ size1 to 7 page 11-9-13 MSQ size10 to 200 page 11-9-18 MSQ with external shock absorber page 11-9-25 1. Perform speed adjustment gradually from the low speed side. Speed adjustment from the high speed side can cause product damage leading to human injury and damage to equipment an machinery. CRB2 CRBU2 CRB1 Caution MSU 1.

33 43 62 82 93 14.5 18.5 27 36 42 10-11-13 13 Series MIW/MIS Dimensions: Single Finger Type MIS-D GC GB GD PE FC LB FA B JA FB LC 2-GA EB JB Scraper mounting thread 2-LA Mounting hole EA C D 2-P Attachment mounting thread 2-FD through Supply port Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258

Calculation of kinetic energy E1 RBQl3213 Stroke absorption (mm) 13 8.5 8 7 4 Using the equation suitable for the classification of impact. Use Formula to calculate E1.

D-A3/A44/A5/A6 D-A59W D-Y59/Y69/Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL D-F5/J5/F5W/J59W D-F5BAL/F5NTL/F59F D-G39/K39 ~ = " Hs A 13 12 7.5 8 7 7 6 6 7 7 " Ht 5.5 5 6 6 5 ~ = 10 10 10 11 11 Since this is a guideline including hysteresis, not meant to be guaranteed.

The gasket part number for the VS7-6 and the VP7-6 is "AXT500-13," and the gasket part number for the VS7-8 and the VP7-8 is "AXT510-13." The VQ7-6 gasket part number is "VQ7060-13-4-1" and the VQ7-8 gasket part number is "VQ7080-13-4-1."

status controller Input current is not applied Apply correcct input current(4 to 20 mADC) 13 Other cause Contact SMC Setting change not available Operation is in 4-20mA mode or JOG mode Change operation mode to parameter mode 15 Other cause Contact SMC 18 Revision history 1st edition: March 2019 Rev.

13 13 14 14 15 D-A3/ A44 9 9 10 11 11 11 * Values which include hysteresis are for guideline purposes only, they are not a 27 - 28 - Auto switch proper mounting position (detection at stroke end) and its mounting height Models with rubber bumper have different dimensions for auto switch proper mounting positions (A to B).

13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 51 Revision history G: Revise Safety Instructions.

Speed control P.13 2-6. Cushion P.13 2-7. Directional control P.13 2-8. Pneumatic circuit P.14 2-9. Adjustment and Operation P.15 3. How to use P.16 3-1. Usage P.16 3-2. Lock release mechanism P.17 3-3. Auto switch P.19 3-4. Wiring method and examples of auto switches P.31 4. Maintenance P.32 4-1. Consumable parts P.32 4-1-1. Seal kit P.32 4-1-2. Storage of seals P.32 4-2.

Tighten them with the cross recessed round head tapping screw 13 . 6. Mount the tube gasket 9 to the right cover 2 to mount to the body 1 . Tighten them with the hexagon socket head cap screw with washers 12 . 17 15 3 10 14 26 11 5 12 19 9 12 14 1 11 26 4 2 6 15 Cushion seal 4 Direction of the shaft(key) 38 - 7.

JIS hexagon socket head bolt is neatly placed in the rotary actuator groove. 4-4 Piping and operating direction Table 6 Size L Bolt 10 13 M 4 15 16 M 4 20 22.5 M 6 30 24.5 M 8 40 28.5 M 8 Fig.6 Fig-7 shows piping ports of the rotary actuator. Table-7 shows the port size.

If the products kinetic energy of the load exceeds the allowable value, it could damage the product, and cause a hazard to humans and damage the machinery and equipment. 13. Provide a shock absorber if the kinetic energy that is applied to the product exceeds the allowable value.

Model Screw Max. tightening Maximum screw-in depth (L mm) torque (Nm) MHZ2-10 M3 x 0.5 0.9 6 MHZ2-16 M4x0.7 1.6 4.5 MHZ2-20 M5 x 0.8 3.3 8 L L MHZ2-25 M6x1 5.9 10 MHZ2-32 M6x1 5.9 10 MHZ2-40 M8 x 1.25 13.7 13 Model Screw Max. tightening torque (Nm) Maximum screw-in depth (L mm) MHZ2-10 M3 x 0.5 0.69 5 MHZ2-16 M4x0.7 2.1 8 MHZ2-20 M5 x 0.8 4.3 10 MHZ2-25 M6x1 7.3 12 MHZ2-32 M6x1 7.9 13 MHZ2

6 MHZ2-16 M40.7 1.6 4.5 MHZ2-20 M50.8 3.3 8 L L MHZ2-25 M61 5.9 10 MHZ2-32 M61 5.9 10 MHZ2-40 M81.25 13.7 13 Nm Lmm MHZ2-10 M30.5 0.69 5 MHZ2-16 M40.7 2.1 8 MHZ2-20 M50.8 4.3 10 MHZ2-25 M61 7.3 12 MHZ2-32 M61 7.9 13 MHZ2-40 M81.25 17.7 16 Nm MHZ2-10 M2.50.45 0.49 MHZ2-16 M30.5 0.88 MHZ2-20 M40.7 2.1 MHZ2-25 M50.8 4.3 MHZ2-32 M50.8 4.3 MHZ2-40 M61 7.3 D-Y59 D-Y69 D-Y7P 7 - 1. 2. 1.