Minimum Stroke for Auto Switch Mounting (mm) Applicable auto switch model No. of auto switches mounted D-A9 D-A9V D-M9 D-M9V D-F9W D-F9WV 1 pc. 5 5 5 2 pcs. 10 10 5 Auto switch model Bore size (mm) Operating Range 6 5 10 6 16 9 D-A9/A9V 3 (2) 3.5 (2) 5.5 (3) D-M9/M9V D-F9W/F9WV Since this is a guideline including hysteresis, not meant to be guaranteed.

D-A9V D-M9V D-F9WV ( ): Denotes the values of D-M9V, D-F9WV.

No.PS-OMH0002CN-D / / / / / / / / ISE70 ISE75(H) 2 8 9 10 13 13 13 14 16 16 21 23 25 26 34 34 36 -1No.PS-OMH0002CN-D (ISO/IEC)(JIS) 1) 2) 1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO

Bore size (mm) Part No. d Cotter pin l d H B Dd9 L C D m (Cut through) Note 1) 3 x 18l 4 x 25l 4 x 35l 0.040 0.076 0.050 0.093 0.065 0.117 NT-03 NT-04 NT-05 NT-08 NT-10 CD-M03 CD-M05 CD-M08 10 14 22 32, 40 50, 63 80, 100 32 40 50, 63 80 100 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 6 8 11 13 16 17 22 27 32 41 19.6 25.4 31.2 37.0 47.3 16.5 21 26 31 39 36 51 72 4 4.5 5 44 60 82 3 4

Materials: 12, 20 Steel 32 to 63 Rolled steel 30 d (mm) Bore (mm) D C H d B C D Part No.

Rail mounting Direct mounting D-F7BA D-F7lW D-F7lF D-J79W D-A7lH/A80H D-A73C/A80C D-F7l/J79 D-F7lV/J79C D-F9BA D-F9lW D-F9lWV D-F7lWV D-A9l D-A9lV D-F9l D-F9lV D-A79W D-A7l/A80 Bore size (mm) D 8 10.5 13.5 16.5 C 11 15 13 15.5 D 9 11.5 14.5 17.5 C 12 16 14 16.5 D 5 7.5 10.5 13.5 C 8 12 10 12.5 B 7 9.5 12.5 15.5 A 10 14 12 14.5 B 10.5 13 16 19 A 13.5 17.5 15.5 18 B 3.5 6 9 12 A 6.5 10.5 8.5

9, D-T99 D-9A, D-S99, S9P High precision type MSUA 90 3 Single vane 7 180 D-R73, D-T79 D-R80, D-S79, S7P 20 1 D-9, D-T99 D-9A, D-S99, S9P 90 Single vane 3 MSUB Double vane 180 7 D-R73, D-T79 D-R80, D-S79, S7P 20 Double vane is available with 90 rotation setting only.

Replacement Parts Description Material Y200P-060S Y300 Y300P-060S Y400 HNBR Y200 Seal Y400P-060S Spacer with Bracket (Z) G Center of F.R.L. body C E BB (Y200T only) 1 EE (Y100T, Y200T only) X-X RELEASE X B 2 E X G Seal Y200T Y400T F J A H K Spacer width D Model Y200T Y300T Y400T B 82 96 BB 67 C 29 41 48 D 53 68 81.5 E 24 35 40 EE 33 F 12 14 18 G 5.5 7 9 G 5.5 7 9 H 19 21 26 J 3.2 4 4

10 1 D-Y59/Y69 2 (Different sides, Same side) D-Y59/Y69/ D-Y7P/Y7PV 6.5 6.5 6 7 7 8 15 25 D-Y7P/Y7PV 1 D-Y7W/Y7WV 6.5 6.5 6 7 7 8 2 (Different sides, Same side) Solid state switch D-Y7W/Y7WV 20 25 1 6 D-Y7BAL 5 5 5 5 5 2 (Different sides, Same side) 20 30 1 D-Y7BAL Center trunnion is not included.

Note 2) When symbols C or D are specified, an auto drain with a part number shown on page 18 is mounted.

***D-A7l, D-A8l, D-F7l and D-J7l are available as option. 4.3-2 Heavy Duty Stopper Cylinder Series RSH Models Applicable auto switch Construction Action Bore size (mm) Reed switch Solid state switch Rod end configuration Mounting Fixed mounting height D-Y5 D-Y6 D-Y7 Double with spring Single/spring extend Flange 20, 32 50, 63 80 D-Z7 D-Z8 Lever with built-in shock absorber MK/MK2 Specifications

80 100 No. of auto switches mounted Type Auto switch model Auto switch model 32 40 50 63 80 100 2 (Different sides, Same side) D-Z7/Z80 Reed switch 15 25 10 10 11 11 12 D-Z7/Z80 10 1 D-Y59/Y69 2 (Different sides, Same side) D-Y59/Y69/ D-Y7P/Y7PV 6.5 6.5 6 7 7 8 15 25 D-Y7P/Y7PV 1 D-Y7W/Y7WV 6.5 6.5 6 7 7 8 2 (Different sides, Same side) Solid state switch D-Y7W/Y7WV 20 25 1 5 5 5 5 6 D-Y7BAL

MY CY Proper Auto Switch Mounting Position MG A B Auto switch model CX D-Y5 D-Y6 D-Y7P D-Y7PV D-Y5 D-Y6 D-Y7P D-Y7PV D-Z7 D-Z80 D-Y7W D-Y7WV D-Y7W D-Y7WV D-Z7 D-Z80 DCylinder model CYP15 24.5 93.5 -X CYP32 33 122 20Data Mounting of Auto Switch When mounting auto switches, they should be inserted into the cylinder's switch groove from the direction shown in the drawing on the right.

MY CY Proper Auto Switch Mounting Position MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B Auto switch model CX D-Y5 D-Y6 D-Y7P D-Y7PV D-Y5 D-Y6 D-Y7P D-Y7PV D-Z7 D-Z80 D-Y7W D-Y7WV D-Y7W D-Y7WV D-Z7 D-Z80 DCylinder model CYP15 93.5 24.5 -X CYP32 122 33 20Data

IODD file 1 D-MP025A/B/C SMC-D-MP025-ymmdd-IODD1.1 2 D-MP050A/B/C SMC-D-MP050-ymmdd-IODD1.1 3 D-MP100A/B/C SMC-D-MP100-ymmdd-IODD1.1 4 D-MP200A/B/C SMC-D-MP200-ymmdd-IODD1.1 : "ymmdd" indicates the file preparation date. y is the year, mm is the month and dd is the date.

Confirm the Coordinates and Moments in Model Selection on page 1229 for details of floating Y and Z axes. 1196 MY1B Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at Stroke End) MY1B (Basic type) 25 to 40 Auto Switch Proper Mounting Position (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model D-A9 D-A9V A A Bore size A 25 32 40 79 83 112.5 116.5 133.5

SG Connector location P3: Not used for the maintenance purpose port D-sub9 (Male receptacle) P2: Serial RS-485 D-sub9 (Female receptacle) P1: Contact input/output D-sub25 (Female receptacle) Power cable entry E S O L C SMC N E P O Rear side 93 Series HRZ Operation Panel Display Description No.

D Note) Be sure to use a flat washer for the A type mounting. b) B type mounting (when using the cylinder tube threads) E t E t Compatible Mounting Bolt Dimensions A type mounting B type mounting Model Mounting bolt size D: Bolt length (mm) E (mm) C (mm) Mounting bolt size MQQTB10-D MQQTB16-D MQQTB20-D MQQTB25-D MQQTB30-D MQQTB40-D MQQLB10-D MQQLB16-D MQQLB20-D MQQLB25-D MQQLB30-D MQQLB40

mounting style Rail mounting style 15 stroke 80 121 D-H7/H7W 15 60 10 30 stroke 88 140 Basic weight D-H7NF 45 stroke 98 164 D-C73C/C80C Note) 15 65 10 60 stroke 110 189 D-H7C Axial foot style 7 19 Mounting bracket weight D-A7/A80 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V D-J79C D-A79W/F7W D-J79W D-F7WV/F79F 10 Rod side flange style 5 13 5 Mounting nut and rod end nut are included in the basic

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series LC6D Stepper Motor Driver Series LX Dedicated How to Order LC 6 D 220 A D CE marking Applicable motor Standard CE marking Nil Q 6 Stepper motor Driver power supply Function D 24VDC D Driver function only Input/Output type A Photo coupler input/