Option (A) 2 1 Nil: F: None With bracket 1 (P) 3 (R) Body type Bracket Function AC Symbol Specifications DC Port size [2(A) port] (0.35 W) p (0.9 W) p Note 3) Nil p Standard C3 C4 C6 M5 3.2 one-touch fitting 4 one-touch fitting 6 one-touch fitting M5 thread (Replaceable type) R Note 1, 2) K Note 1) High pressure type p p External pilot type KR Note 1, 2) (0.9 W) p High pressure/External
Furthermore, if the cable length exceeds 5 m, then it will decrease by up to 10% for every additional 5 m. (At 15 m: Reduced by up to 20%) 12. When checking the conductivity of the cable, be careful not to deform the connectors mating hole and terminals.
Lead wire length symbols: 0.5 m Nil 1 m M 3 m L 5 m Z (Example) M9NW (Example) M9NWM (Example) M9NWL (Example) M9NWZ Since there are other applicable auto switches than listed, refer to page 167 for details. For details about auto switches with pre-wired connector, refer to pages 1784 and 1785.
MULTI COUNTER:CEU5 UP M/C COUNT PRESET FUNC. LEFT RIGHT DOWN SEL.
Note q Lead wire and M12 connector (3 m), Straight ZS-37-A 1 pc. w Lead wire and M12 connector (3 m), Right angle ZS-37-B 1 pc. e Assembly-type connector PCA-1557743 1 pc. r Adapter with restrictor Rc1/4 ZS-31-X175 1 pc. t Adapter with restrictor Rc1/8 ZS-31-X188 1 pc. y Orice M5 ZS-48-A 1 pc. u q + e ZS-37-A-X448 The lead wire and connector are Nil Voltage output type 1 to 5 V 28 Current
Nil Left R Right D Both left and right LEC LEC S *5 Select D for the vacuum port for suction of 50 L/min (ANR) or more. LEC SS-T R: Right !1 I/O cable length [m]*10 o Cable length [m]*6, *9 LEC Y Nil Without cable H Without cable (Connector only) 1 1.5 *9 The length of the encoder, motor and lock cables are the same.
For EE (ZSE4E) 24 V 12 V 6 V 5 V 3 V 5 6 V S R Lead wire length 0.5 (2.9) m NPN output Analog output PNP output 27 26 67 Lead wire length 0.5 (2.9) m Lead wire length 0.5 (2.9) m Not required for Nil, vacuum adapter (GN) and vacuum pressure gauge (G).
Leakage voltage Take note that the leakage voltage will increase when a resistor is used in parallel with a switching element or when a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the leakage voltage passing through the C-R circuit. The suppressor residual leakage voltage should be as follows.
Leakage voltage Take note that the leakage voltage will increase when a resistor is used in parallel with switching element or a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the passing leakage voltage through the C-R circuit. The suppressor residual leakage voltage should be as follows. Design / Selection 1.
Completion drawing Plate A Hexagon socket button bolt (M6x8) With gasket(M-6G) Tightening torque 10.1Nm Plug(M-3P) (4 pcs) Tighten by hand, and give it an additional turn approx. 1/4 rotations with a wrench.
Basic inertia moment 2 r m I = m : Weight of load (kg) r : Load center of gravity and distance of rotation axis. (m) r m Fig. (10) Inertia moment This shows inertia moment of m (weight) at r from the rotation axis. Calculation of inertia moment depends on the shape of the object.
How to Use Conduit Terminal Light/Surge Voltage Suppressor DC Polar type With surge voltage suppressor S Grommet of L/M-type plug connector With light/surge voltage suppressor Z DIN or Conduit terminal With light/surge voltage suppressor Non-polar type With surge voltage suppressor R Grommet or L/M-type plug connector With light/surge voltage suppressor U DIN or Conduit terminal With light
(Example: If the Pressure switch with output impedance of 1k is connected to the A/D converter to detect the analog output of 5 V, the detected voltage by the A/D converter becomes 5(V) 1(M)/(1(k) + 1(M)) 4.995(V), and there is an error of approximate 0.005 V.) Output impedance R The pressure range in which the Pressure switch satisfies the specifications.
Plate A Plug (M-3P) (2 pcs.)
M5 M5 M5 M5 1)When using SMCs fitting, etc. After tightening by hand, give it additional 1/6 turn with a wrench. (1/4 turn for miniature fittings.) In case that two gaskets are equipped such as universal elbow or universal tee, give it additional 1/2 turn with a wrench.
(1 ) 2. 3. 0 12 2 13 R 13 R R (GFCI) GFCI 1 GFCI 13-2 13-1 1. 2. 3. 4. GFCI 5. 6. 7. 13 1 13 R 13-2 IDFA6E-20-R 5A 30mA 13-3 1) 2) 3) 9.5mm M5 1.25mm 2 L N 6.5mm M3 1.25mm 2 6-3 14-3 13 2 14 T 14 T T 14-2, 14-3 14-1 1. 2. 3. GFCI 4. 5. GFCI 6. 7. 8. 9.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed, refer to page 249 for details. For details about auto switches with pre-wired connector, refer to pages 1784 and 1785.
ZP3PG20JT2SF-M-7A-X2 21 ZP3P-20JT2SF-WM ZP3P 32 JT2 SF ZP3PG32JT2SF-7A-X2 48 ZP3P-32JT2SF-W ZP3PA-T2JT-7A-X2 ZP3P 32 JT2 SF M ZP3PG32JT2SF-M-7A-X2 48 ZP3P-32JT2SF-WM ZP3P 20 JT5 SF ZP3PG20JT5SF-7A-X2 23 ZP3P-20JT5SF-WG ZP3PA-T1JT-7A-X2 ZP3P 25 JT5 SF ZP3PG25JT5SF-7A-X2 25 ZP3P-25JT5SF-WG ZP3P 32 JT5 SF ZP3PG32JT5SF-7A-X2 54 ZP3PA-T2JT-7A-X2 ZP3P-32JT5SF-WG Input the material symbol (N, S,
Altitude [m] 1. Max. ambient 2. Cooling capacity temp.