90 0.5 W W W 0.5 F 117 108 95 76 0.7 C J G5-S 0.1 0 500 1000 1500 81 75 66 51 0.3 CV G 60 55 49 37 0.5 Cylinder stroke (mm) The above curve in the graph refers to P = 0.5 MPa of supply pressure.

Air dryer model IDF100FS-30-R IDF125FS-30-R IDF150FS-30-R Breaker capacity 20 A 30 A Sensitivity current: 30 mA Corrosion is not covered under warranty. Option symbol V With a timer controlled solenoid valve type auto drain Option symbol Float type heavy duty auto drain is changed to the solenoid valve type auto drain.

Calculation Pad W P S t : Lifting force (N) : Vacuum pressure (kPa) : Pad area (cm 2) : Safety factor Horizontal lifting: 4 or more Vertical lifting: 8 or more Horizontal lifting Vertical lifting W = P x S x 0.1 x 1 t This type of application should basically be avoided.

This is not a clean room series product. 4 MACM Series Dimensions W (Workpiece loadable range) 4 x D At maximum offset (A + 2 x S) S F DB DA C X114 X115, X116 U B W A H T H Q PB E PA PD P (Unlocking port) PE P (Locking port) P (Relief port) (Option V only) MACM4, MACM6 MACM2, MACM10 PC PC PC PC PE P (Relief port) (Option V only) PD [mm] Dimensions Model A B C D DA DB E F H P PA PB PC PD

Conduit terminal w/ indicator light For obtaining the flow rate, refer to page 4-1-6.

2 @6 t @4 w @8 r !1 @5 @3 @2 e !6 A A C B M(D)LUB25 y !9 i o !5 @0 Extension locking w q Section A-A !

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: T (Panel Mount Adapter for w/

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: Y (w/o Operation

Series: 25A-PFM7, Flow Rate Range: 11 [2 to 100 (50) L/min], Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Operation Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: w/o Lead Wire, Bracket: None, Operation Manual: w/o Operation Manual, w/

A B W A B W A B W 12 6.2 6.2 3.8 6.2 6.2 1.8 6.2 6.2 5.8 6.2 6.2 3.8 16 6.7 6.7 3.3 6.7 6.7 1.3 6.7 6.7 5.3 6.7 6.7 3.3 20 7.5 10 7.5 10 7.5 10 2 7.5 10 25 8 12 8 12 8 12 8 12 Auto Switch Mounting Height U [mm] Auto switch model Bore size D-M9V, D-M9WV, D-M9AV U 12 19.5 16 21 20 23 25 24.5 W A B A Operating Range [mm] Auto switch model Applicable bore size 12 16 20 25 D-M9m(V)/M9mW

186 q Installation Distance and Discharge Time p. 182 Alarm p. 186 w Static Neutralization Range p. 183 Mode Switch Setting p. 187 e Pressure Flow Rate Characteristics p. 184 Wiring p. 187 Dimensions p. 188 How to Order p. 185 Accessories (for Individual Parts) p. 185 Related Products p. 189 Specifications p. 186 AC Adapter Specifications p. 186 Specific Product Precautions p. 190 Parts

N.O. q r w Design Caution 1. Design the system so that the mist separator is installed in a pulsation-free location. The difference between internal and external pressure inside the element should be kept within 0.1 MPa, as exceeding this value could cause damage. e Selection Drain Caution 1. Do not allow air flow that exceeds the rated flow.

Description Material AFM40 AFM40-06 AFM20 AFM30 Element assembly Bowl O-ring Bowl assembly (1) NBR PC AFM20P-060AS C2SFP-260S C2SF AFM30P-060AS C3SFP-260S C3SF (2) AFM40P-060AS C4SFP-260S C4SF (2) AFM40P-060AS C4SFP-260S C4SF (2) w e r Note 1) Including O-Ring. Please contact SMC regarding the bowl assembly supply for PSI and F unit specifications.

HOW TO ORDER N V F 1 1 0 H s D Z O 0 1 T F T T Opo.afing Pressure -J I 0 100 psi (CrP.055) | ' H 0 r 150 psi (C\p.05) | Solenr io vAc 3 _ KYPS" 4-2mVAC E l{vF 1100-oc{17 @io.rg None F Foot Bracket --R(PT),Mekic' T NPTF (Std.) N _ N P T Ii ; o Electrical Corinsctioi G 12'Lead (Sd.) D .

Axis Movement Speed Position Acceleration Deceleration Pushing Area 2 In-position 2) 2) mode (mm/s) (mm) (mm/s (mm/s Selection (mm) (mm) (mm) 1 CIR-R 100 100.00 1000 1000 0.0 0.0 0.5 2 CIR-R 100.00 0.0 0.0 0.5 0 1) 50.00 3 1) 50.00 4 () () 1) CIR-R CIR-L 1 2 34 (5) SYN-I Area 1 Step No.

, Grommet terminal, Conduit terminal, DIN terminal 1 (P) 3 (R) Note 1) Use dry-air at low temperature.