For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V] x 1% = 0.04[V]) F.S. (Full span, Full scale) H Hysteresis The difference between ON and OFF points used to prevent chattering. Hysteresis can be effective in avoiding the effects of pulsation.
URL http://www.smcworld.com -10 V to 10 V -20 mA to 20 mA for 2 hours each in direction X, Y and Z respectively (De-energized) 24 VDC Class2, 2 A 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 0 V to 10 V 0 mA to 20 mA Content Content Content 0 V to 10 V 0 mA to 20 mA 0 V to 10 V 0 mA to 20 mA
The power supply voltage between the power supply terminal PWR_24V and PWR_GND is outside of DC24 V +/10%. Power supply Use a power supply voltage of DC24 V+/-10%. PWR LED: error PWR signal: 1 Green flashing Continue OFF (Outside of 24 (Cycle: 1 Hz) V+/-10%) The power supply voltage between the power supply terminal PWR_24V and PWR_GND is below 17 V.
indication (2-color indicator) 2-wire 3-wire (PNP) 12 V 3-wire (NPN) 3-wire (PNP) IC circuit With timer 5 V,12 V 3-wire IC circuit E76A 5 V (NPN equivalent) Yes Grommet E73A E80A 24 V 12 V 5 V,12 V 100 V 2-wire Relay, PLC IC circuit N0 100 V or less Lead wire length symbols: 0.5 mNil (Example) M5BW 3 m L (Example) M5BWL 5 m Z (Example) M5BWZ Solid state auto switches marked with are produced
5 V, 12 V 100 V 100 V or less IC circuit IC circuit Relay, PLC Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV 3-wire Reed switch Solid state switch Yes Grommet 24 V 2-wire No 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 5 V, 12 V IC circuit BMP1-032 12 V Relay, PLC 24 V Grommet Yes Diagnostic indication (2-color indication) 5 V, 12 V IC circuit 12 V 2-wire Water resistant (2-color
5 V, 12 V 100 V 100 V or less Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV IC circuit IC circuit Relay, PLC 3-wire Reed switch Solid state switch Yes Grommet 24 V 2-wire No 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 5 V, 12 V IC circuit BMP1-032 12 V Relay, PLC 24 V Grommet Yes Diagnostic indication (2-color indication) 5 V, 12 V IC circuit 12 V 2-wire Water resistant (2-color
(If the button is pressed for less than 2 seconds, the setting will be returned to P.)
How to use P. 15 3-1. Usage 3-2. Lock release mechanism 4. Maintenance P. 18 4-1. Checks 4-1-1. Inspection points 4-1-2. Inspection interval 5. Troubleshooting P. 19 6. Construction P. 24 -1- Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
VCA20-12-1A 41 52 30 40 4.5 6 VCA30-12-1A 48 56 36 44 5.5 7 VCA40-12-1A 50 62 38 50 5.5 7 2 mounting screws (for mounting brackets) are included in bracket part no. 17-2-12 7 Series VCA Direct Operated 2 Port Solenoid Valve For Air Dimensions Grommet: G Conduit: C Q F D Q F 300 280 D VC G1/2 C R C R L VDW IN E E VQ Manual override A B B A 2-P Port size 2-P Port size VX2 VX Manual override
Bore Size G H .125 .125 0.38 No5-40UNC 0.56 0.44 NY-P006 6 (1/4) 0.32 0.44 .188 .188 0.56 No10-32UNF 0.94 0.75 NY-J015 10 (3/8) 0.39 0.54 .188 .188 0.56 No10-32UNF 0.94 0.75 NY-J015 15 (5/8) 0.39 0.54 D I M E N S I O N S C L E V I S A N D T R U N N I O N P I N d m t Part No Bore Size D L l .095 0.03 0.018 NCT-P006 6 (1/4) .125 0.81 0.70 .147 0.04 0.029 NCT-P010 10 (3/8) .188 0.94 0.81 .147
100 V, 200 V 12 V 2-wire 24 V CJ1 No 200 V or less Relay, PLC Yes Connector 24 V or less 5 V, 12 V No IC circuit CJP Grommet Diagnostic indication (2-color indication) Yes 3-wire (NPN) 3-wire (PNP) IC circuit CJ2 5 V, 12 V Grommet 12 V 2-wire CM2 Connector 3-wire (NPN) IC circuit Relay, PLC 5 V, 12 V Diagnostic indication (2-color indication) Yes 3-wire (PNP) 24 V CG1 Courtesy of Steven
24 V Grommet Yes 3-wire(NPN) IC circuit Diagnosis (2-color indication) 5 V, 12 V 3-wire(PNP) 12 V 2-wire Auto switches marked with a symbol are produced upon receipt of order.
Request message
Request message
Operating pressure: P (MPa) 3. Weight of total loads: Wo (kg) Wo = (Load weight: WA) + (Jig weight: WB) 4. Operating piston speed: v (mm/s) Calculate required output FA 9.8 x Wo FA = Take next larger bore size than D Operating pressure (MPa) 0.4 0.2 0.5 0.3 0.6 0.4 or more Check Theoretical Output FO Fo: Refer to "Theoretical Output" on page 2.
10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)1 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 4 to 20 mA ?2.5% F.S.?
or more / 5 mA or more(At NPN input, between the pin for input terminal and for sensor supplied voltage of +24 V) (At PNP input, between the pin for input terminal and for sensor supplied voltage of 0 V)5 V or less / 1 mA or less(At NPN input, between the pin for input terminal and for sensor supplied voltage of +24 V) (At PNP input, between the pin for input terminal and for sensor supplied
10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)0.6 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 2.4 to 20 mA ?2.5% F.S.?
or more / 5 mA or more(At NPN input, between the pin for input terminal and for sensor supplied voltage of +24 V) (At PNP input, between the pin for input terminal and for sensor supplied voltage of 0 V)5 V or less / 1 mA or less(At NPN input, between the pin for input terminal and for sensor supplied voltage of +24 V) (At PNP input, between the pin for input terminal and for sensor supplied
or more / 5 mA or more(At NPN input, between the pin for input terminal and for sensor supplied voltage of +24 V) (At PNP input, between the pin for input terminal and for sensor supplied voltage of 0 V)5 V or less / 1 mA or less(At NPN input, between the pin for input terminal and for sensor supplied voltage of +24 V) (At PNP input, between the pin for input terminal and for sensor supplied