VM2 SMC 74 45 40 54 Max. deflection position Unlock position Lock position 14 40.8 7 Stroke 3 Symbol (A) 4 (B) 2 32 26.5 20.5 11 53 (72) B 12 14 A 3 (EB) 1 (P) 5 (EA) 2 x M5 x 0.8 (Port 3, 5) 39.2 33.2 27.2 2 x Rc1/8 (Port 2, 4) Rc1/8 (Port 1) Travel required for operation 3 Full Operating Force (F .O.F .) 55 N (at 0.5 MPa) 3 x 6.5 mounting hole Travel required to release the lock 7 Force
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in3.2M5 x 0.8AS1201FG-M5-23AS1211FG-M5-23AS1301FG-M5-23AS1311FG-M5-23
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in3.2M5 x 0.8AS1201FG-M5-23AS1211FG-M5-23AS1301FG-M5-23AS1311FG-M5-23
Please contact us for the latest version.sales@ocaire.com, SPEED CONTROL W/FITTING, AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, A5, AS***F M5 CLEAN-ROOM, .01675 lb, Applicable tubing O.D. (mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in4M5 x 0.8AS1201FG-M5-04AS1211FG-M5-04AS1301FG-M5-04AS1311FG-M5-04
Standard part number X1 Clean room specifications Specifications Non-grease specifications Cleanliness Bleed port Class 10 With M5 fitting (applicable tube O.D. 6) Manifold Specifications (except type IR2120 and series IR3000) 6 IR1000/2000: M5 fitting (applicable tube O.D. 6) IR3000: Rc(PT) 1/2 female thread EXH port Grease Teflon grease 2 to 8 station manifold type regulators.
x 0.8 M5 x 0.8 Rc 1/8 Bore size (mm) NN T S Z K KA L MM P Q R Standard strokes 20 25 32 M5 x 0.8 with depth 8 M5 x 0.8 with depth 8 M6 x 1.0 with depth 9 9.3 with depth 8 9.3 with depth 9 11 with depth 11.5 53 51.5 56 72 74.5 83 30 38 48 5 6 7 5 6 8 M6 x 1.0 M8 x 1.25 M10 x 1.25 5.5 5.5 6.6 16 20 24 13 23.5 29 20, 30, 40, 50, 60, 70, 80, 90, 100 4 Series CU Auto Switch Proper Mounting Positions
Series AS-FG How to Order AS 1 0 3 2 F G 01 06 Body size M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard 1 2 3 4 Option Type Nil S None With seal 2 3 Elbow Universal M5 and U10/32 are not available with seal. Control type Applicable tubing O.D.
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in4M5 x 0.8AS1201FG-M5-04AS1211FG-M5-04AS1301FG-M5-04AS1311FG-M5-04
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in6M5 x 0.8AS1201FG-M5-06AS1211FG-M5-06AS1301FG-M5-06AS1311FG-M5-06
Please contact us for the latest version.sales@ocaire.com, SPEED CONTROL W/FITTING, AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, A5, AS***F M5 CLEAN-ROOM, 1.79968 lb, Applicable tubing O.D. (mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in3.2M5 x 0.8AS1201FG-M5-23AS1211FG-M5-23AS1301FG-M5-23AS1311FG-M5-23
power increases. *2 When the piping thread type "F (G thread)" or "N (NPT thread)" is selected, it becomes "G thread " or "NPT thread ". 3 When the option-T3 is selected, the weight increases by 18 kg . 4 No change in external dimensions.
MY1 3.4-11 End Lock Cylinder Series CBA1 40, 50, 63, 80, 100 How to Order L 50 150 H N CBA1 Standard L 50 150 A53 H N CDBA1 With auto switch Number of auto switches Air cylinder with auto switch 2 1 n S n Mounting Basic Axial foot Front flange Rear flange Single clevis Double clevis Center trunnion B L F G C D T Style Auto switch Lube Non-lube Steel tube N F Without auto switch Refer
These vortexes are stable under certain conditions, and their frequency is proportional to the flow velocity, resulting in the following formula. f = k x v f: Frequency of vortexes, v: Flow velocity, k: Proportional constant (determined by the vortex generator's dimensions, shape, etc.) Therefore, the flow rate can be measured by detecting this frequency.
n_1 H_1 CoL ISA3-F: [20], ISA3-G: [50], ISA3-H: [50] ISA3-F: [3], ISA3-G: [20], ISA3-H: [20] Display Thank you for purchasing an SMC ISA3-#L series Gap Checker.
The SYJ Valve is an innovative combination of space efficiency and performance superiority which provides real value to the design solution. Whether designed in a manifold or used as a single valve, this small profile increases design flexibility and minimizes space requirements. The SYJ valve utilizes a low power (0.5 watts standard) pilot solenoid design, which dramatically reduces thermal
The SYJ Valve is an innovative combination of space efficiency and performance superiority which provides real value to the design solution. Whether designed in a manifold or used as a single valve, this small profile increases design flexibility and minimizes space requirements. The SYJ valve utilizes a low power (0.5 watts standard) pilot solenoid design, which dramatically reduces thermal
AS Series Speed Controller with One-touch Fittings In-line Type RoHS AS-F AS-F TMH ASD AS AS-FE KE AS-FG 4 types of mounting variations 4 types of mounting variations AS-FP AS-FM DIN rail mounting DIN rail mounting Direct mounting Direct mounting AS-D AS-T L-bracket mounting L-bracket mounting ASP Holder mounting Holder mounting ASN AQ DIN rail mounting bracket ASV AK Holder for speed controller
port) S + Stroke N 52 3 x 1/4 (Rc, NPT, G) (Piping port) 20 17 30 10 W 2 x Speed controller valve Top width across flats 3 11.5 3 14 45 45 M16 x 1.5 45 Hs 30 IA IB 40 35 20 38 Width across flats 17 F 4 x M6 Thread depth 12 R15 0.050 d90.093 +0.027 H8 0 Shaft: 12 Hole: 12 97 ZZ + Stroke Z + Stroke Clevis width CKP1A: 16.5 CKP1B: 19.5 CKP1C: 12.5 +0.3 0 +0.4 0 +0.5 0 Unit: mm 40 Symbol F IA
Power Clamp Cylinder/CKZ3T -X2734 (Base Type) -X2568 (With Manually Operated Handle) Equivalent bore size [mm] Body material Port Arm opening angle Switch 50, 63 Aluminum G, NPT, Rc 15, 30, 45, 60, 75 90, 105, 120, 135 TURCK, P&F, None The simple switch adjustment greatly reduces work hours. The switch can be adjusted easily when changing the arm opening angle.
[F 5] [ FnC] Select FUNC (switching Analogue output 2/ External input) [ oUt] Analogue output PF3A706H Equivalent to M5 3 Nm10% 8 PF3A712H 9 Equivalent to M6 5.2 Nm10% : Arbitrary display mode can be added to the sub display by setting the [F10] sub display.