Actuation: 2 (2 Position Double), Seal: 1 (Rubber Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 2 (200VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: Dust Protected
Actuation: 3 (3 Position Closed Center), Seal: 1 (Rubber Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 2 (200VAC 50/60Hz), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: Dust Protected
Actuation Type: 1 (2 Position Single), Sealant: 0 (Metal Seal), Function: Standard (1W), Voltage: 2 (200VAC 50/60HZ), Light & Surge Suppressor: w/Light and Surge Suppressor, Manual Override: Non-locking Push Style, Protection: Dust Proof, 1: 1
Actuation: 3 (3 Position Closed Center), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 2 (200VAC 50/60Hz), Light/Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required)
Actuation Type: 4 (3 Position Exhaust Center), Sealant: 1 (Rubber Seal), Function: Standard (1W), Voltage: 2 (200VAC 50/60HZ), Light & Surge Suppressor: w/Light and Surge Suppressor, Manual Override: Non-locking Push Style, Protection: Dust Proof, 1: 1
CY36 Consult with SMC in case a bracket with weight exceeding the above value is to be mounted. 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1000 2000 3000 4000 5000 6000 CY315 Note 1) According to the dead weight deflection in the figure on the right, provide clearance so that the cylinder does not touch the mounting surface or the load, etc., and is able
7 -X NBR Valve retainer seal #7 Since there is a possibility of improper operation, please contact SMC regarding the replacement of seals. 20Data 10-12-21 21 Series CE1 Dimensions: 12, 20 Both ends tapped style: CE1B Bore size Stroke 2-P (Port size) 2-N through 4-O thread depth R Metal connector 500 or 3000 M14 x 1 B + Stroke A + Stroke A B C D E G H I K L M Bore size (mm) 12 20 Standard
Bore size (mm) NT-02 NT-04 NT-04 NT-05 NT-05 NT-08 NT-10 B C d D H 12.5 21 21 26 26 31 39 5 8 8 11 11 13 16 15 25.4 25.4 31.2 31.2 37 47.3 M8 x 1.25 M14 x 1.5 M14 x 1.5 M18 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 20 32 40 50 63 80 100 13 22 22 27 27 32 41 256 Auto Switch Mounting CHQB/CHQWB Series Refer to pages 431 to 490 for detailed specifications.
For more information, please refer to page 8-16-21. Note 2) With 25, piping screws can be selected by the customer. (Refer to How to Order.)
Mounting orientation and static moment Mounting orientation Static load Horizontal mounting Ceiling mounting Wall mounting Vertical mounting Bore size (mm) A [mm] 6 10 15 20 25 32 40 m m x g x x m x g x y 19 21 25 27 33 40 49 m x g x x m x g x y m x g x (z + A) m x g x x m x g x (z + A) m x g x y M1 M2 M3 Static moment A: Distance between the center of the guide shaft and the upper surface
Weightp. 21 Internal Circuits and Wiring Examplesp. 22 Exhaust Characteristics/Flow Rate Characteristicsp. 23 Time to Reach Vacuum/Break Flow Rate Characteristics/Vacuum Breaking Time p. 24 Constructionp. 25 How to Order Replacement Partsp. 26 Dimensionsp. 27 Specific Product Precautionsp. 31 Safety Instructions Back cover 6 Multistage Ejector Max. suction flow rate: 100 L/min (ANR) Only
3 Steel wire Round head Phillips screw Nickel plated 20, 30, 40 Replacement Parts Part no. 10 15 20 30 40 Description Description Seal kit P473010-1 P473020-1 P473030-1 P473040-1 P473050-1 19, 20, 21, 23 11-8-4 5 Series CRQ2 Compact Rotary Actuator Rack & Pinion Style Construction With auto switch Size 10/15 With auto switch Size 20/30/40 !3 !0 !3 !0 CRB2 CRBU2 CRB1 MSU !4 !7 !1 !9 !
The standard angle adjustment range of 5 (one side) is changed to in this type. + 5 95 (mm) E Mounting screw Y Q Stroke 1 to 4 6 to 9 11 to 14 16 to 19 21 to 24 26 to 29 31 to 39 41 to 49 51 to 65 66 to 74 76 to 90 91 to 99 1 to 4 6 to 9 11 to 14 16 to 19 21 to 24 26 to 29 31 to 39 41 to 49 51 to 65 66 to 74 76 to 90 91 to 99 Size 58.5 ( 5 Stroke)/2 61 ( 10 Stroke)/2 61 ( 15 Stroke)
7 -X NBR Valve retainer seal #7 Since there is a possibility of improper operation, please contact SMC regarding the replacement of seals. 20Data 10-12-21 21 Series CE1 Dimensions: 12, 20 Both ends tapped style: CE1B Bore size Stroke 2-P (Port size) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800)
Be careful not to exchange the power cable (brown) with the output cable (black). 7-9-20 21 Solid State Switch Direct Mounting Style D-F8N/D-F8P/D-F8B For details about certified products conforming to international standards, visit us at www.smcworld.com.
-X Centering can be done easily. 13 18 + Stroke 33 20Tolerance h9 8 Rod cover Data CDUJB8-15D 21 13.5 18 + Stroke 38 Compliant for clean room Clean Series 10 CDUJB10-20D 1011-Series CUJ 22 Two auto switches can be installed even for 4 mm strokes. CU Length is shortened by approx. 64% max. Volume is reduced by approx. 70% max.
For more information, please refer to page 8-16-21. Note 2) With 25, piping screws can be selected by the customer. (Refer to How to Order.)
They should be used only to provide support. q l 50 m 40 (450) 30 MY2C40 l l 20 (380) MY2C25 MY2C16 w 10 0 2000 1000 mm 1500 500 Support spacing l 8-13-20 21 Mechanically Jointed Rodless Cylinder High Precision Guide Type Series MY2H/2HT 16, 25, 40 How to Order MX MTS H MY2 G 16 300 L M9N MY Number of auto switches CY Guide type 2 pcs. 1 pc. n pcs.
(Refer to Relationship between Supply Pressure and Display on page 21.)
humidity Material Impact resistance Standards/Directive CE (EMC Directive: 2004/108/EC) Note) When the air purge is performed between a charged object and an ionizer at a distance of 300 mm Number of emitter cartridges/Bar weight 340 5 590 740 860 Bar length symbol 400 6 640 790 910 460 7 690 840 960 580 9 790 940 1060 640 10 830 980 1100 820 13 980 1130 1250 1120 18 1220 1370 1490 1300 21