10 KJ4D 8 6.0 5 18 11 27 10 10 M4 x 0.7 13 12 KJ6D 9 6.75 6 20 13 30 12 11 M6 x 1 13 16 KJ6D 9 6.75 6 20 13 30 12 11 M6 x 1 13 20 KJ8D 12 9 8 24 16 36 16 13 M8 x 1.25 14 25 KJ10D 14 10.5 10 28 19 43 20 15 M10 x 1.25 13 Floating Joint: JA In the case of dimension without C M M U U D F B G B E E H C P A [mm] Bore size Part no.
(mm) 02 04 06 08 10 13 16 20 25 32 40 50 2 4 6 8 10 13 16 20 25 32 40 50 Pad type 02 04 06 08 10 13 16 20 25 32 40 50 2 4 6 8 10 13 16 20 25 32 40 50 Pressure gauge position Thread dia.
10 87 12 139 13 1/8 10 1/8 Up to 300 13 14 12 102 13 162 14 1/4 12 1/4 Up to 300 13 14 12 102 13 162 14 1/4 12 1/4 Up to 300 20 17 122 196 20 3/8 17 3/8 Up to 300 20 17 122 196 20 1/2 17 1/2 Up to 300 1206 Smooth Cylinder Series CG1Y With Mounting Bracket Axial foot style: CG1YL LH B LT 2 x LC ZZ + Stroke LS + Stroke M W W X Y X Y Z LX (Knock pin position) 4 x LD LZ Axial Foot Style (
24 24 23 13 23 126 127 137 8 25 72 73 83 13 24 24 23 13 23 130 131 141 8 32 72 75 83 13 24 24 21 13 21 130 133 141 8 40 93 96 101 16 24 24 21 16 21 159 162 167 11 Axial foot: CBM2L Bore size Stroke A * -H -R -W N L ZZ + Stroke LS + Stroke N L CBM2G Bore size Stroke A Head flange: * -H -R -W Rod flange: CBM2F Bore size Stroke A * -H -R -W N L Z + Stroke Single clevis: CBM2C Bore size
119 12 12 1/8 12.5 12.5 M5 x 0.8 32 79 11 11 121 12 12 1/8 10.5 10.5 1/8 40 87 12 12 139 13 13 1/8 13 10 1/8 Up to 1500 50 102 13 13 162 14 14 1/4 14 14 1/4 63 102 13 13 162 14 14 1/4 14 14 1/4 80 122 196 20 20 3/8 17.5 17.5 3/8 100 122 196 20 20 1/2 17.5 17.5 1/2 Female Rod End (mm) Bore size A1 H MM ZZ 20 8 13 M4 x 0.7 92 25 8 14 M5 x 0.8 93 32 12 14 M6 x 1 95 40 13 15 M8 x 1.25 104
Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.
Weight [g] Auto switch model D-M9N(V) D-M9P(V) D-M9B(V) 0.5 8 8 7 Precautions Caution 1 14 14 13 Lead wire length (m) 3 41 41 38 Fix the auto switch with the existing screw installed on the auto switch body.
PD Mounting 20 12 12 13 24.2 6 25 12 10 (12) 13 26.7 6 32 12 10 (12) 13 30.2 6 40 12 10 (12) 16 34.6 8 50 13 13 20 40.6 10 63 13 13 20 47.1 10 HH Applicable Tubing O.D./I.D. Note) ( ): Long stroke Bore size (mm) 20 25 32 40 50 63 Applicable tubing O.D. (mm) 6/4 6/4 6/4 8/6 10/7.5 10/7.5 Applicable tubing material Can be used for either nylon, soft nylon or polyurethane tubing.
CG1(K)R series Width across flats B2 Width across flats MA MI MM2 H2 MK Stroke MT ML + Adjustment MH + Stroke + Adjustment S + Stroke ZZ + 2 x Stroke + Adjustment (A: 25 mm, B: 50 mm) CG1(K)R Series (mm) B2 10 13 13 17 19 19 H2 3.6 5 5 6 8 8 MA 12 17 17 19 24 24 MH 38 41 41 47 60 60 MI 14 20 20 25 32 32 MK 7 9 9 10 13 13 ML 18 18 18 24 32 32 MM2 M6 x 1 M8 x 1.25 M8 x 1.25 M10 x 1.25 M14 x
Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.
For Safety Instructions and Actuator Precautions, refer to pages 7-13-3 to 7-13-6.
Grommet D-F7NV/F7PV/F7BV 12-13-13 Rail D-J79C Connector 12-13-14 DD-F59/F5P/J51/J59 Grommet 20D-S991/S992/S99V1/S99V2 D-T991/T992/T99V1/T99V2 D-S9P1/S9P2/S9PV1/S9PV2 Grommet D-S791/S792 D-T791/T792 Direct D-S7P1/S7P2 Connector D-T791C/T792C D-F8N/F8P/F8B 12-13-15 D-M9N/M9P/M9B D-M9NV/M9PV/M9BV D-Y59A/Y7P/Y59B D-Y69A/Y7PV/Y69B 12-13-16 Grommet 12-13-17 D-F79W/F7PW/J79W Grommet Rail
Grommet D-F7NV/F7PV/F7BV 12-13-13 Rail D-J79C Connector 12-13-14 DD-F59/F5P/J51/J59 Grommet 20D-S991/S992/S99V1/S99V2 D-T991/T992/T99V1/T99V2 D-S9P1/S9P2/S9PV1/S9PV2 Grommet D-S791/S792 D-T791/T792 Direct D-S7P1/S7P2 Connector D-T791C/T792C D-F8N/F8P/F8B 12-13-15 D-M9N/M9P/M9B D-M9NV/M9PV/M9BV D-Y59A/Y7P/Y59B D-Y69A/Y7PV/Y69B 12-13-16 Grommet 12-13-17 D-F79W/F7PW/J79W Grommet Rail
60 M3 x 12 1.5 M4 x 12 1.5 14 4.5 NY M4 x 0.7 7 70 50 4.6 13 60 M3 x 12 1.5 M4 x 12 1.5 11 4.5 NW M5 x 0.8 8.5 70 50 4.6 13 60 M4 x 12 2.5 M4 x 12 1.5 9 4.5 NU M5 x 0.8 8.5 70 50 4.6 13 60 M3 x 12 1.5 M4 x 12 1.5 11 4.5 NT M5 x 0.8 8.5 70 50 4.6 17 60 M3 x 12 1.5 M4 x 12 1.5 12 8.5 NM2 M4 x 0.7 8 50 38.2 11.5 60 M3 x 12 1.5 M4 x 12 2.7 10 12 32 NZ M5 x 0.8 9 70 50 4.6 11 60 M4 x 12 3.6
Note 13) For an actuator with lock, add the power consumption for the lock.
[mm] [mm] Size CRB2 CRBU2 X Y X Y 10 3 to 14 1 to 8 1 to 14 1 to 8 15 4 to 18 1.5 to 9 1.5 to 18 1.5 to 9 20 4.5 to 20 1.5 to 10 1.5 to 20 1.5 to 10 30 5 to 22 2 to 13 2 to 22 2 to 13 40 18 to 30 4.5 to 15 18 to 30 4.5 to 15 Size CRB2 CRBU2 X Y X Y 10 3 to 10 (19) 1 to 12 (3) 1 to 3 (12) 1 to 19 (10) 15 4 to 11.5 1.5 to 15.5 1.5 to 6.5 1.5 to 20.5 20 4.5 to 13 1.5 to 17 1.5 to 7.5 1.5 to
Weight [g] Auto switch model D-M9N D-M9P D-M9B 0.5 m (Nil) 8 7 1 m (M) 14 13 Lead wire length 3 m (L) 41 38 5 m (Z) 68 63 Dimensions [mm] D-M9 Mounting screw M2.5 x 4 L Slotted set screw (fat point) Indicator light 2.6 3.95 2.8 22.8 2.6 6 Most sensitive position 30 Normally Closed Solid State Auto Switch Direct Mounting Type D-M9NE(V)/D-M9PE(V)/D-M9BE(V) Refer to the SMC website for details
Weight Auto Switch Internal Circuit D-F79 (g) D-F79 D-F7P D-J79 Auto switch model DC (+) Brown 13 11 13 0.5 Lead wire length (m) 57 50 57 3 Main circuit of switch Main circuit of switch OUT Black 92 81 92 5 DC () Blue Dimensions 3.5 mounting hole D-F7P Indicator light DC (+) Brown OUT Black DC () Blue D-J79 Most sensitive position OUT (+) Brown Main circuit of switch OUT () Blue 10-20-32
CLS CLQ Auto Switch Internal Circuit D-H7A1 MLGP Weight RLQ (g) DC (+) Brown D-H7A1 D-H7A2 D-H7B Auto switch model MLU Main circuit of switch Main circuit of switch Main circuit of switch 11 13 13 0.5 OUT Black Lead wire length (m) 50 57 57 3 ML1C 81 92 92 5 DDC () Blue Dimensions -X D-H7A2 20DC (+) Brown Data OUT Black DC () Blue Indicator light D-H7B 3.5 mounting hole OUT (+) Brown Most
-X 20Data Weight Auto Switch Internal Circuit D-J79C (g) D-J79C Auto switch model OUT (+) Brown 13 0.5 Lead wire length (m) 52 3 Main circuit of switch 83 5 OUT () Blue Dimensions 3.2 mounting hole Indicator light Most sensitive position 8-30-27 28 Solid State Switch Direct Mounting Style D-M9N(V)/D-M9P(V)/D-M9B(V) For details about certified products conforming to international standards